STAR*NET V6 - Circe
STAR*NET V6 - Circe
STAR*NET V6 - Circe
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
INLINE OPTION: .SCALE Value<br />
Chapter 5 Preparing Input Data<br />
This option applies to 2D/3D “Local” coordinate system jobs only. When the “Apply an<br />
Average Scale Factor” option is selected in the Project Options/Adjustment dialog, this<br />
inline option allows you to change the entered scale factor. The scale factor is used to<br />
scale horizontal distances, or the horizontal components of slope distances. You can<br />
insert this inline option into your data as many times as needed to vary the scale in your<br />
project. If the “.SCALE” inline is entered without a scale value, the scale factor is reset<br />
to the default value originally set in the Project Options.<br />
INLINE OPTION: .PELEVATION Value<br />
This option applies to “2D” local and grid jobs only. It allows you to redefine a default<br />
project elevation for various parts of a project when you feel the elevation changes<br />
enough to make a difference in the results. A reference elevation for a station used in<br />
calculations is assigned the first time the station name is seen in your data. Therefore by<br />
careful placement of this inline in your data, you can accurately assign reference<br />
elevations to stations in different regions of your project.<br />
In the example below, assume the “Default Project Elevation” in set to 1000 in the<br />
Project Options. Stations 1, 2 and 4 will have a reference elevation of 1000 assigned and<br />
stations 5, 6 and 7 a reference elevation of 875.<br />
C 1 20000 20000 ! !<br />
C 2 20007.432 19182.223 ! !<br />
M 1-2-4 89-53-22 842.12<br />
.PELEV 875 #Change default to 875<br />
C 5 21543.244 22832.432 ! !<br />
M 5-4-6 67-25-11 645.98<br />
M 6-5-7 87-56-38 987.12<br />
.PELEV #Reset to project default<br />
etc...<br />
As shown above, entering the “.PELEVATION” inline option with no value, resets to the<br />
original default setting in the Project Options.<br />
INLINE OPTION: .COPYINPUT ON/OFF<br />
When the “Copy of Input Data Files” option in the Project Options/Listing File dialog is<br />
selected, your data file or files are copied to the listing file. Using this inline option, you<br />
can completely control which parts on your data will be copied, and which parts will not.<br />
This option is very useful for excluding bulky sections from your listing file that you<br />
don’t really care to see. Simply place a “.COPY OFF” inline before any group of lines<br />
you wish not to be copied to the listing file, and then a “.COPY ON” inline where you<br />
wish to resume copying. When the “Copy of Input Data Files” listing option is turned off<br />
in the Project Options, the “.COPY” inline has no affect.<br />
82