Instrument Options<br />

Standard Error Settings<br />

Chapter 4 Options<br />

Standard errors are used in weighting your data. In this dialog, you enter standard error<br />

values for most types of observations used in an adjustment. Your observations will<br />

default to these values unless explicit values are entered with the observations in your<br />

data, or unless you use “Instrument Library” inline options to apply alternate values.<br />

Linear and angular units shown in this dialog are based on the project units set in the<br />

Adjustment Options. If you change the units settings in the Adjustment Options dialog<br />

(from FeetUS to Meters, or DMS to GONS for example), the standard error values and<br />

their displayed units in the dialog shown above are automatically converted. You never<br />

have to manually convert standard error values from one unit to another.<br />

When working in DMS, angular standard errors are entered in seconds. And when<br />

working in GONS, standard errors are entered in milligons, where one milligon is equal<br />

to 1/1000 GON. (There are about 0.309 milligons per second.)<br />

Standard error values initially provided as defaults during program installation are<br />

arbitrary. You should always reset the values to those consistent with the actual<br />

instruments and procedures used for your project! If you determine that your projects<br />

normally use certain option values, you can change the startup defaults for new projects<br />

by revising the values in the Company Options. See “Company Options” later in this<br />

chapter for details.<br />