TIA-568B <strong>and</strong> FOTP-171A Certified Reference <strong>Cable</strong>s<br />

= new producT = Replacement paRt = accessoRy<br />

572J<br />

www.greenlee.com<br />

Ensures accurate measurements for repeatable <strong>and</strong> reproducible testing to<br />

the latest industry st<strong>and</strong>ards.<br />

meets <strong>and</strong>/or exceeds the latest industry st<strong>and</strong>ards including:<br />

• TIA/EIA-455-171 (FOTP-171A), issued June, 2001.<br />

• TIA-568B, TIA-562-7 (OFSTP-7) <strong>and</strong> TIA-526-14 (OFSTP-14) for optical<br />

link testing.<br />

• TIA-455-171 (FOTP-171, Attenuation) <strong>and</strong> TIA-455-8 (FOTP-8,<br />

Return Loss) for cable assembly testing.<br />

• Corresponding IEC measurement st<strong>and</strong>ards.<br />

sPeCIFICAtIoNs<br />

Ferrule oD 2.4990 ±0.0005 mm<br />

Fiber to Ferrule<br />

eccentricity<br />

< 0.25µm (SM) <strong>and</strong> < 3µm (MM)<br />

Insertion Loss < 0.15dB (SM, 1310/1550nm) <strong>and</strong> < 0.25dB (MM, 850/1300nm)<br />

return Loss > 55dB (SM, 1310/1550nm) <strong>and</strong> > 40dB (MM, 850/1300nm)<br />

beam exit Angle < 0.25° (SM) <strong>and</strong> < 0.5° (MM)<br />

st<strong>and</strong>ard Length 3 m<br />

stANDArD reFereNCe CAbLes (tYPe A to tYPe b)<br />

DesCrIPtIoN CAt No. UPC No. DesCrIPtIoN CAt No. UPC No. CAt No. UPC No.<br />

Single-mode Reference <strong>Cable</strong>s: Multimode Reference <strong>Cable</strong>s: 50/125 62.5/125<br />

FC-PC to FC-PC 562K-101 60658 FC-PC to FC-PC 562K-105 60659 562K-106 60660<br />

ST-PC to ST-PC 563K-101 60661 ST-PC to ST-PC 563K-105 60662 563K-106 60663<br />

SC-PC to SC-PC 566K-101 60664 SC-PC to SC-PC 566K-105 60665 566K-106 60666<br />

E2000-PC to E2000-PC 56E2-101 60667 E2000-PC to E2000-PC 56E2-105 60668 56E2-106 60669<br />

LC-PC to LC-PC 56LC-LSM 60670 LC-PC to LC-PC 56LC-LM5 60671 56LC-LM6 60672<br />

MU-PC to MU-PC 56MU-LFM 60676 MU-PC to MU-PC 56MU-LM5 60674 56MU-LM6 60675<br />

HYbrID reFereNCe CAbLes (FC-PC to tYPe A)<br />

DesCrIPtIoN CAt No. UPC No. DesCrIPtIoN CAt No. UPC No. CAt No. UPC No.<br />

Single-mode Reference <strong>Cable</strong>s: Multimode Reference <strong>Cable</strong>s: 50/125 62.5/125<br />

FC-PC to FC-APC 572J-101 60680<br />

FC-PC to SC-APC 576J-101 60681<br />

FC-PC to E2000-APC 57E8-101 60682<br />

FC-PC to LC-PC 57LC-LSM 60733 FC-PC to LC-PC 57LC-LM5 60734 57LC-LM6 60735<br />

FC-PC to MU-PC 57MU-LFM 60736 FC-PC to MU-PC 57MU-LM5 60737 57MU-LM6 60738<br />

262A<br />

To measure attenuation of SM links with APC polished connectors, use<br />

our 262A Dual Wavelength Laser Source (see page 327) with the APC-<br />

108 FC UCI Adapter (see page 329) <strong>and</strong> a Hybrid Reference <strong>Cable</strong>. Use<br />

same hybrid reference cable approach for LC-PC <strong>and</strong> MO-PC connectors.<br />

Communications<br />

USA CANADA INTERNATIONAL<br />

Tel: 800.435.0786 Tel: 800.435.0786 Tel: +1.815.397.7070<br />

Fax: 800.451.2632 Fax: 800.524.2853 Fax: +1.815.397.9247<br />