Grass Sensotronic Cabinet Planning Notes on the electronics The power supply unit The power supply unit should be placed near a power outlet (power cord length approx. 2 m). Please note the “range” of the power supply unit of approx. 5 m and the number of cabinet members which can be connected (see System Description, page 3). If separate cabinet blocks are planned (e.g. cooker island), one power supply unit per cabinet block is recommended. For safety reasons, the power supply unit must not be fitted beneath a sink. An installation height (must be fitted upright) of 23 cm is to be provided. Mains connection: Voltage supply: 90 - 240V Mains frequency: 50 / 60 Hz Max. output: 240W Other notes Neither the drawer nor the cabinet member is energised. All live parts are fully enclosed and inaccessible. 1 2 7 2 3 In the event of a power outage, the drawers can be opened and closed conventionally. Needless to say, all the data entered when configuring the system are retained in the case of a power outage. Operating conditions: Temperature: +/- 0º to +50 ºC Humidity: 15% to 90% Notes for cabinet planning Provide switchable power outlets (e.g. to allow the user to switch the system off when going on holiday or cleaning the drawers). Required inside cabinet depth: NL + 79 mm. Use Sensotronic for modern furniture planning and incorporate fronts which are flush with the cabinet sides. Determine the depth of the cabinet sides on the basis of the front thickness used and the largest front gap defined for the cabinet. Front gap with Sensotronic To ensure reliable activation when opening the drawer by tapping, an activation distance of 3 mm is required. This gives a front gap (space between drawer front and front edge of cabinet) of 3 mm. The activation zone encompasses the full width of the front. Depending on the stability of the pullout and/or the rigidity of the front, it will be possible to tap at different heights with a front gap of this size. Front buffers will enlarge the front gap. The drawer The screw positions of the cabinet member are the same as on the standard Nova Pro cabinet member. Special applications where there is resistance for either the opening or closing operation cannot be used with the standard software (e.g. waste disposal pull-outs with lift-up lid, some plinth drawers, backward sloping slides, etc.). 6 HAA GS08 www.hafele.com 4 8 6 3 5

The manual ‘push to open’ solution for drawers and interior pull-outs REFER TO THE HÄFELE GRASS DRAWER PROGRAM CATALOGUE FOR ORDERING DETAILS The handle free solution for hinged doors REFER TO THE COMPLETE HÄFELE 2007/2008 CATALOGUE FOR ORDERING DETAILS (CATALOGUE PAGE 3.60 ONWARDS) HAA GS08 www.hafele.com 7

Grass <strong>Sensotronic</strong> Cabinet Planning<br />

Notes on the electronics<br />

The power supply unit<br />

The power supply unit should be<br />

placed near a power outlet (power<br />

cord length approx. 2 m). Please note<br />

the “range” of the power supply unit of<br />

approx. 5 m and the number of<br />

cabinet members which can be<br />

connected (see System Description,<br />

page 3). If separate cabinet blocks are<br />

planned (e.g. cooker island), one<br />

power supply unit per cabinet block is<br />

recommended. For safety reasons,<br />

the power supply unit must not be<br />

fitted beneath a sink. An installation<br />

height (must be fitted upright) of 23<br />

cm is to be provided.<br />

Mains connection:<br />

Voltage supply: 90 - 240V<br />

Mains frequency: 50 / 60 Hz<br />

Max. output: 240W<br />

Other notes<br />

Neither the drawer nor the cabinet<br />

member is energised. All live parts are<br />

fully enclosed and inaccessible.<br />

1<br />

2<br />

7<br />

2 3<br />

In the event of a power outage, the<br />

drawers can be opened and closed<br />

conventionally. Needless to say, all<br />

the data entered when configuring<br />

the system are retained in the case<br />

of a power outage.<br />

Operating conditions:<br />

Temperature: +/- 0º to +50 ºC<br />

Humidity: 15% to 90%<br />

Notes for cabinet planning<br />

Provide switchable power outlets<br />

(e.g. to allow the user to switch the<br />

system off when going on holiday or<br />

cleaning the drawers). Required<br />

inside cabinet depth: NL + 79 mm.<br />

Use <strong>Sensotronic</strong> for modern furniture<br />

planning and incorporate fronts<br />

which are flush with the cabinet<br />

sides. Determine the depth of the<br />

cabinet sides on the basis of the<br />

front thickness used and the largest<br />

front gap defined for the cabinet.<br />

Front gap with <strong>Sensotronic</strong><br />

To ensure reliable activation when<br />

opening the drawer by tapping, an<br />

activation distance of 3 mm is required.<br />

This gives a front gap (space between<br />

drawer front and front edge of cabinet)<br />

of 3 mm. The activation zone<br />

encompasses the full width of the front.<br />

Depending on the stability of the pullout<br />

and/or the rigidity of the front, it will<br />

be possible to tap at different heights<br />

with a front gap of this size.<br />

Front buffers will enlarge the front gap.<br />

The drawer<br />

The screw positions of the cabinet<br />

member are the same as on the<br />

standard Nova Pro cabinet member.<br />

Special applications where there is<br />

resistance for either the opening or<br />

closing operation cannot be used with<br />

the standard software (e.g. waste<br />

disposal pull-outs with lift-up lid, some<br />

plinth drawers, backward sloping slides,<br />

etc.).<br />

6 HAA GS08 www.hafele.com<br />

4<br />

8<br />

6 3<br />

5