Refrigeration System Section 7<br />
REFRIGERANT RE-USE POLICY<br />
<strong>Manitowoc</strong> recognizes and supports the need for proper<br />
handling, re-use, and disposal of, CFC and HCFC<br />
refrigerants. <strong>Manitowoc</strong> service procedures require<br />
recapturing refrigerants, not venting them to the<br />
atmosphere.<br />
It is not necessary, in or out of warranty, to reduce or<br />
compromise the quality and reliability of your customers’<br />
products to achieve this.<br />
Important<br />
<strong>Manitowoc</strong> <strong>Ice</strong>, Inc. assumes no responsibility for<br />
use of contaminated refrigerant. Damage resulting<br />
from the use of contaminated, recovered, or<br />
recycled refrigerant is the sole responsibility of the<br />
servicing company.<br />
<strong>Manitowoc</strong> approves the use of:<br />
1. New Refrigerant<br />
• Must be of original nameplate type.<br />
2. Reclaimed Refrigerant<br />
• Must be of original nameplate type.<br />
• Must meet ARI Standard 700 (latest edition)<br />
specifications.<br />
3. Recovered or Recycled Refrigerant<br />
• Must be recovered or recycled in accordance<br />
with current local, state and federal laws.<br />
• Must be recovered from and re-used in the same<br />
<strong>Manitowoc</strong> product. Re-use of recovered or<br />
recycled refrigerant from other products is not<br />
approved.<br />
• Recycling equipment must be certified to ARI<br />
Standard 740 (latest edition) and be maintained<br />
to consistently meet this standard.<br />
• Recovered refrigerant must come from a<br />
“contaminant-free” system. To decide whether<br />
the system is contaminant free, consider:<br />
<strong>–</strong> Type(s) of previous failure(s)<br />
<strong>–</strong> Whether the system was cleaned, evacuated<br />
and recharged properly following failure(s)<br />
<strong>–</strong> Whether the system has been contaminated<br />
by this failure<br />
<strong>–</strong> Compressor motor burnouts and improper<br />
past service prevent refrigerant re-use.<br />
<strong>–</strong> Refer to “System Contamination Cleanup” to<br />
test for contamination.<br />
4. “Substitute” or “Alternative” Refrigerant<br />
• Must use only <strong>Manitowoc</strong>-approved alternative<br />
refrigerants.<br />
• Must follow <strong>Manitowoc</strong>-published conversion<br />
procedures.<br />
7-30 Part Number 80-1634-3