Refrigeration System Section 7<br />

INSTALLATION/VISUAL INSPECTION CHECKLIST WATER SYSTEM CHECKLIST<br />

Possible Problem Corrective Action<br />

<strong>Ice</strong> machine is not level Level the ice machine<br />

Condenser is dirty Clean the condenser<br />

Water filtration is plugged (if<br />

used)<br />

Install a new water filter<br />

Water drains are not run<br />

separately and/or are not<br />

vented<br />

Line set is improperly<br />

installed<br />

Run and vent drains<br />

according to the Installation<br />

<strong>Manual</strong><br />

Reinstall according to the<br />

Installation <strong>Manual</strong><br />

A water-related problem often causes the same<br />

symptoms as a refrigeration system component<br />

malfunction.<br />

Water system problems must be identified and<br />

eliminated prior to replacing refrigeration components.<br />

Possible Problem Corrective Action<br />

Water area (evaporator) is<br />

dirty<br />

Clean as needed<br />

Water inlet pressure not<br />

between 20 and 80 psi<br />

(1-5 Bar, 138- 552 kPa)<br />

Incoming water temperature<br />

is not between 35°F (1.6°C)<br />

and 90°F (32.2°C).<br />

Water filtration is plugged (if<br />

used)<br />

Water dump valve leaking<br />

during the freeze cycle<br />

Vent tube is not installed on<br />

water outlet drain<br />

Hoses, fittings, etc., are<br />

leaking water<br />

Install a water regulator valve<br />

or increase the water<br />

pressure<br />

If too hot, check the hot water<br />

line check valves in other<br />

store equipment<br />

Install a new water filter<br />

Clean/replace dump valve as<br />

needed<br />

See Installation Instructions<br />

Repair/replace as needed<br />

Water fill valve is stuck open Clean/replace as needed<br />

Water is spraying out of the Stop the water spray<br />

sump trough area<br />

Uneven water flow across the Clean the ice machine<br />

evaporator<br />

Water is freezing behind the Correct the water flow<br />

evaporator<br />

Plastic extrusions and Remount/replace as needed<br />