Refrigeration System Section 7<br />
INSTALLATION/VISUAL INSPECTION CHECKLIST WATER SYSTEM CHECKLIST<br />
Possible Problem Corrective Action<br />
<strong>Ice</strong> machine is not level Level the ice machine<br />
Condenser is dirty Clean the condenser<br />
Water filtration is plugged (if<br />
used)<br />
Install a new water filter<br />
Water drains are not run<br />
separately and/or are not<br />
vented<br />
Line set is improperly<br />
installed<br />
Run and vent drains<br />
according to the Installation<br />
<strong>Manual</strong><br />
Reinstall according to the<br />
Installation <strong>Manual</strong><br />
A water-related problem often causes the same<br />
symptoms as a refrigeration system component<br />
malfunction.<br />
Water system problems must be identified and<br />
eliminated prior to replacing refrigeration components.<br />
Possible Problem Corrective Action<br />
Water area (evaporator) is<br />
dirty<br />
Clean as needed<br />
Water inlet pressure not<br />
between 20 and 80 psi<br />
(1-5 Bar, 138- 552 kPa)<br />
Incoming water temperature<br />
is not between 35°F (1.6°C)<br />
and 90°F (32.2°C).<br />
Water filtration is plugged (if<br />
used)<br />
Water dump valve leaking<br />
during the freeze cycle<br />
Vent tube is not installed on<br />
water outlet drain<br />
Hoses, fittings, etc., are<br />
leaking water<br />
Install a water regulator valve<br />
or increase the water<br />
pressure<br />
If too hot, check the hot water<br />
line check valves in other<br />
store equipment<br />
Install a new water filter<br />
Clean/replace dump valve as<br />
needed<br />
See Installation Instructions<br />
Repair/replace as needed<br />
Water fill valve is stuck open Clean/replace as needed<br />
Water is spraying out of the Stop the water spray<br />
sump trough area<br />
Uneven water flow across the Clean the ice machine<br />
evaporator<br />
Water is freezing behind the Correct the water flow<br />
evaporator<br />
Plastic extrusions and Remount/replace as needed<br />
gaskets are not secured to<br />
the evaporator<br />
7-6 Part Number 80-1634-3