S1800 Marine Model Ice Machines – Service Manual - Manitowoc Ice
S1800 Marine Model Ice Machines – Service Manual - Manitowoc Ice
S1800 Marine Model Ice Machines – Service Manual - Manitowoc Ice
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Refrigeration System Section 7<br />
DRIER<br />
HEAT<br />
EXCHANGER<br />
HIGH PRESSURE VAPOR<br />
COMPRESSOR<br />
RECEIVER<br />
(WATER COOLED ONLY)<br />
HIGH PRESSURE LIQUID<br />
EXPANSION VALVE<br />
HOT GAS SOLENOID VALVE<br />
STRAINER<br />
LOW PRESSURE LIQUID<br />
Figure 7-2. Self-Contained Harvest Cycle<br />
Harvest Cycle Refrigeration Sequence<br />
Hot gas flows through the energized harvest valve,<br />
heating the evaporator. The harvest valve is sized to<br />
allow the proper amount of refrigerant into the<br />
evaporator. This specific sizing (along with the proper<br />
system refrigerant charge) assures proper heat transfer,<br />
without the refrigerant condensing and slugging the<br />
compressor.<br />
EVAPORATOR<br />
AIR OR WATER<br />
CONDENSER<br />
LOW PRESSURE VAPOR<br />
SV1570<br />
7-2 Part Number 80-1634-3