Refrigeration System Section 7<br />

DRIER<br />

HEAT<br />

EXCHANGER<br />

HIGH PRESSURE VAPOR<br />

COMPRESSOR<br />

RECEIVER<br />

(WATER COOLED ONLY)<br />

HIGH PRESSURE LIQUID<br />

EXPANSION VALVE<br />

HOT GAS SOLENOID VALVE<br />

STRAINER<br />

LOW PRESSURE LIQUID<br />

Figure 7-2. Self-Contained Harvest Cycle<br />

Harvest Cycle Refrigeration Sequence<br />

Hot gas flows through the energized harvest valve,<br />

heating the evaporator. The harvest valve is sized to<br />

allow the proper amount of refrigerant into the<br />

evaporator. This specific sizing (along with the proper<br />

system refrigerant charge) assures proper heat transfer,<br />

without the refrigerant condensing and slugging the<br />

compressor.<br />

EVAPORATOR<br />

AIR OR WATER<br />

CONDENSER<br />

LOW PRESSURE VAPOR<br />

SV1570<br />

7-2 Part Number 80-1634-3