Section 6 Electrical System<br />
ICE/OFF/CLEAN TOGGLE SWITCH<br />
Function<br />
The switch is used to place the ice machine in ICE, OFF<br />
or CLEAN mode of operation.<br />
Specifications<br />
Single-pole, single-throw switch. The switch is<br />
connected into a varying low D.C. voltage circuit.<br />
Check Procedure<br />
NOTE: Because of a wide variation in D.C. voltage, it is<br />
not recommended that a volt meter be used to check<br />
toggle switch operation.<br />
1. Inspect the toggle switch for correct wiring.<br />
2. Isolate the toggle switch by disconnecting the Molex<br />
connector.<br />
3. Check continuity across the toggle switch terminals.<br />
Note where the wire numbers are connected to the<br />
switch terminals, or refer to the wiring diagram to<br />
take proper readings.<br />
Switch Setting Terminals Ohm Reading<br />
1-6 Open<br />
ICE<br />
1-2 Closed<br />
2-6 Open<br />
1-6 Closed<br />
CLEAN<br />
1-2 Open<br />
2-6 Open<br />
1-6 Open<br />
OFF<br />
1-2 Open<br />
2-6 Open<br />
4. Replace the toggle switch if ohm readings do not<br />
match all three switch settings.<br />