Section 6 Electrical System<br />

There are other problems that may cause compressor<br />

start-up failure with a good PTCR in a new, properly<br />

wired ice machine.<br />

• The voltage at the compressor during start-up is too<br />

low.<br />

<strong>Manitowoc</strong> ice machines are rated at ±10% of<br />

nameplate voltage at compressor start-up. (Ex: An<br />

ice machine rated at 208-230 should have a<br />

compressor start-up voltage between 187 and 253<br />

volts.)<br />

• The compressor discharge and suction pressures<br />

are not matched closely enough or equalized.<br />

These two pressures must be somewhat equalized<br />

before attempting to start the compressor. The<br />

harvest valve (and HPR valve on remotes) energizes<br />

for 45 seconds before the compressor starts, and<br />

remains on 5 seconds after the compressor starts.<br />

Make sure this is occurring and the harvest valve<br />

(and HPR solenoid) coil is functional before<br />

assuming that the PTCR is bad.<br />

CHECKING THE PTCR<br />

! Warning<br />

Disconnect electrical power to the entire ice<br />

machine at the building electrical disconnect box<br />

before proceeding.<br />

1. Visually inspect the PTCR. Check for signs of<br />

physical damage.<br />

NOTE: The PTCR case temperature may reach 210°F<br />

(100°C) while the compressor is running. This is normal.<br />

Do not change a PTCR just because it is hot.<br />

2. Wait at least 10 minutes for the PTCR to cool to<br />

room temperature.<br />

3. Remove the PTCR from the ice machine.<br />

4. Measure the resistance of the PTCR as shown<br />

below. If the resistance falls outside of the<br />

acceptable range, replace it.<br />

<strong>Model</strong><br />

<strong>Manitowoc</strong><br />

Part Number<br />

Cera-Mite<br />

Part Number<br />

<strong>Manitowoc</strong> PTCR 8504913<br />

Room<br />

Temperature<br />

Resistance<br />

<strong>S1800</strong>M 8504913 305C9 8-22 Ohms<br />

SV1541<br />

Part Number 80-1634-3 6-17