Electrical System Section 6<br />

S-<strong>Model</strong> Automatic Shut-Off and Restart<br />

When the storage bin is full at the end of a harvest cycle,<br />

the sheet of cubes fails to clear the water curtain and will<br />

hold it open. After the water curtain is held open for 30<br />

seconds, the ice machine shuts off. To assure the PTCR<br />

has cooled, the ice machine remains off for 3 minutes<br />

before it can automatically restart.<br />

The ice machine remains off until enough ice has been<br />

removed from the storage bin to allow the ice to fall clear<br />

of the water curtain. As the water curtain swings back to<br />

operating position, the bin switch closes and the ice<br />

machine restarts, provided the three-minute delay period<br />

is complete.<br />

L1<br />

L1<br />

CONTACTOR<br />

CONTACTS<br />

C<br />

R<br />

S<br />

COMPRESSOR<br />

RUN CAPACITOR<br />

R R<br />

PTCR<br />

During Start-Up (First .25 - 1.0 Seconds)<br />

CONTACTOR<br />

CONTACTS<br />

C<br />

R<br />

S<br />

RUN CAPACITOR<br />

R R<br />

COMPRESSOR<br />

PTCR<br />

After Start-Up<br />

(Current Flows Through Run Capacitor)<br />

L2<br />

SV1506<br />

L2<br />

SV1507<br />

Troubleshooting PTCR’s<br />

WHY A GOOD PTCR MAY FAIL<br />

TO START THE COMPRESSOR<br />

The PTCR must be cooled before attempting to start the<br />

compressor, otherwise the high starting torque may not<br />

last long enough.<br />

For example, if the PTCR is properly cooled, say 60°F<br />

(15.6°C) when the compressor starts, it will take .25 to<br />

1.0 seconds before its temperature reaches 260°F<br />

(126.6°C), and current flow is stopped.<br />

If the PTCR is still warm, say 160°F (71.1°C) when the<br />

compressor starts, it will take only .125 to .50 seconds<br />

before its temperature reaches 260°F (126.6°C), and<br />

current flow is stopped. This decreased time may be<br />

insufficient to start the compressor.<br />

A good PTCR may be too hot to operate properly at<br />

start-up because:<br />

• The ice machine’s 3-minute delay has been<br />

overridden. Opening and closing the service<br />

disconnect or cycling the toggle switch from OFF to<br />

ICE will override the delay period.<br />

• The control box temperature is too high. Though<br />

rare, very high air temperatures (intense sunlight,<br />

etc.) can greatly increase the temperature of the<br />

control box and its contents. This may require a<br />

longer off time to allow the PTCR to cool.<br />

• The compressor has short-cycled, or the compressor<br />

overload has opened. Move the toggle switch to OFF<br />

and allow the compressor and PTCR to cool.<br />

Continued on next page …<br />

6-16 Part Number 80-1634-3