Section 6 Electrical System<br />

6. HARVEST<br />

The harvest valve(s) remains open<br />

and the refrigerant gas warms the<br />

evaporator. This causes the cubes to<br />

slide, as a sheet, off the evaporator<br />

and into the storage bin.<br />

The sliding sheet of cubes swings the<br />

water curtain out, opening the bin<br />

switch. This momentary opening and<br />

closing of the bin switch terminates<br />

the Harvest Cycle and returns the ice<br />

machine to the Freeze Cycle (steps<br />

3-4).<br />

The air compressor (when used)<br />

remains energized throughout the<br />

entire harvest cycle. The air<br />

compressor will automatically<br />

energize after 60 seconds when the<br />

harvest cycle time exceeded 75<br />

seconds in the previous cycle.<br />

Table 6-6. Self-Contained <strong>Model</strong>s<br />

L1<br />

(88)<br />

Ground<br />

(89)<br />

High<br />

Pressure<br />

Cutout<br />

(42)<br />

(55)<br />

<strong>Ice</strong> Thickness<br />

Probe<br />

Water Level Probe<br />

Contactor<br />

Contacts<br />

(Black)<br />

L1<br />

Overload<br />

(51) (85)<br />

Control Board<br />

(2)<br />

(6)<br />

(5)<br />

(1)<br />

(7)<br />

(4)<br />

Trans.<br />

Fuse (7a)<br />

Water Valve<br />

(21)<br />

(22)<br />

Harvest Valve<br />

(77)<br />

(80)<br />

SV3137-7<br />

6. Harvest (Until Bin Switch Activation)<br />

Toggle Switch ICE<br />

Bin Switch Closed<br />

Control Board Relays<br />

#1 Water Pump OFF<br />

#2 Harvest Valve (Left) ON<br />

#3 Harvest Valve (Right) ON (When Used)<br />

#4 Air Compressor ON (When Used)<br />

#5 Water Inlet Valve OFF<br />

#6 Water Dump Valve OFF<br />

#7 Contactor Coil Closed / ON<br />

#7A Compressor ON<br />

#7B Condenser Fan Motor OFF; May Cycle ON<br />

Safety Controls (Which could stop ice machine operation)<br />

High Pressure Cut-Out Closed<br />

Main Fuse (On Control Board) Closed<br />

Part Number 80-1634-3 6-7<br />

Low DC<br />

Voltage<br />

Plug<br />

(Red)<br />

Fan Cycle<br />

Control<br />

(9)<br />

L2<br />

(25)<br />

(8)<br />

Compressor<br />

(86)<br />

(Yellow)<br />

(61)<br />

(26)<br />

(1)<br />

(2)<br />

(20)<br />

(60)<br />

(57)<br />

(6)<br />

(46)<br />

(58)<br />

Dump Valve<br />

(76)<br />

(81)<br />

Water Pump<br />

(98)<br />

(59)<br />

Terminates at<br />

Pin Connection<br />

Contactor Coil<br />

(56)<br />

Air Compressor<br />

Bin Switch<br />

PTCR<br />

Fan Motor<br />

Clean<br />

OFF<br />

ICE<br />

Run Capacitor<br />

(74)<br />

Run Capacitor<br />

(45)<br />

(50)<br />

(99)<br />

(75)<br />

L2 or N