Section 6 Electrical System<br />

2. REFRIGERATION SYSTEM<br />

START-UP<br />

The compressor starts after the 45second<br />

water purge, and it remains<br />

on throughout the Freeze and<br />

Harvest cycles.<br />

The water fill valve is energized at<br />

the same time as the compressor.<br />

The harvest valve(s) remains on for<br />

the first 5 seconds of the initial<br />

compressor start-up and then shuts<br />

off.<br />

At the same time the compressor<br />

starts, the condenser fan motor (aircooled<br />

models) is supplied with<br />

power throughout the entire freeze<br />

and harvest sequences.<br />

The fan motor is wired through a fan<br />

cycle pressure control, and may<br />

cycle on and off. (The compressor<br />

and the condenser fan motor are<br />

wired through the contactor. Any time<br />

the contactor coil is energized, the<br />

compressor and fan motor are<br />

supplied with power.)<br />

L1<br />

(88)<br />

Ground<br />

(89)<br />

High<br />

Pressure<br />

Cutout<br />

(42)<br />

Self-Contained — Refrigeration System Start-Up<br />

Table 6-2. Self-Contained <strong>Model</strong>s<br />

2. Refrigeration System Start Up (5 Seconds)<br />

Toggle Switch ICE<br />

Bin Switch<br />

Control Board Relays<br />

Closed<br />

#1 Water Pump OFF<br />

#2 Harvest Valve (Left) ON<br />

#3 Harvest Valve (Right) ON (When Used)<br />

#4 Air Compressor ON (When Used)<br />

#5 Water Inlet Valve ON<br />

#6 Water Dump Valve OFF<br />

#7 Contactor Coil Closed / ON<br />

#7A Compressor ON<br />

#7B Condenser Fan Motor OFF<br />

Safety Controls (Which could stop ice machine operation)<br />

High Pressure Cut-Out Closed<br />

Main Fuse (On Control Board) Closed<br />

(55)<br />

<strong>Ice</strong> Thickness<br />

Probe<br />

Water Level Probe<br />

Contactor<br />

Contacts<br />

(Black)<br />

L1<br />

Overload<br />

(51) (85)<br />

Control Board<br />

(2)<br />

(6)<br />

(5)<br />

(1)<br />

(7)<br />

(4)<br />

Trans.<br />

Fuse (7a)<br />

Water Valve<br />

(21)<br />

(22)<br />

Harvest Valve<br />

(77)<br />

(80)<br />

SV3137-4<br />

Part Number 80-1634-3 6-3<br />

Low DC<br />

Voltage<br />

Plug<br />

(Red)<br />

Fan Cycle<br />

Control<br />

(9)<br />

L2<br />

(25)<br />

(8)<br />

Compressor<br />

(86)<br />

(Yellow)<br />

(61)<br />

(26)<br />

(1)<br />

(2)<br />

(20)<br />

(60)<br />

(57)<br />

(6)<br />

(46)<br />

(58)<br />

Dump Valve<br />

(76)<br />

(81)<br />

Water Pump<br />

(98)<br />

(59)<br />

Terminates at<br />

Pin Connection<br />

Contactor Coil<br />

(56)<br />

Air Compressor<br />

Bin Switch<br />

PTCR<br />

Fan Motor<br />

Clean<br />

OFF<br />

ICE<br />

Run Capacitor<br />

Run Capacitor<br />

(45)<br />

(74)<br />

(50)<br />

(99)<br />

L2 or N<br />

(75)