Installation Instructions Section 2<br />

Self-Contained Electrical Wiring Connections<br />

! Warning<br />

These diagrams are not intended to show proper<br />

wire routing, wire sizing, disconnects, etc., only the<br />

correct wire connections.<br />

All electrical work, including wire routing and<br />

grounding, must conform to local, state and national<br />

electrical codes.<br />

Though wire nuts are shown in the drawings, the ice<br />

machine field wiring connections may use either<br />

wire nuts or screw terminals.<br />

SELF CONTAINED ICE MACHINE<br />

115/1/60 OR 208-230/1/60<br />

SV1258<br />

L 1<br />

GROUND<br />

ICE MACHINE<br />

CONNECTIONS<br />

For United Kingdom Only<br />

N=115V<br />

OR<br />

L2=208-230V<br />

L 1<br />

GROUND<br />

TO SEPARATE<br />

FUSE/BREAKER<br />

SELF CONTAINED ICE MACHINE<br />

208-230/3/60<br />

SELF CONTAINED ICE MACHINE<br />

230/1/50<br />

2-4 Part Number 80-1634-3<br />

SV1190<br />

SV1191<br />

L 1<br />

L 2<br />

L 3<br />

GROUND<br />

L 1<br />

N<br />

GROUND<br />

ICE MACHINE<br />

CONNECTIONS<br />

ICE MACHINE<br />

CONNECTIONS<br />

L 1<br />

L 2<br />

L 3<br />

GROUND<br />

TO SEPARATE<br />

FUSE/BREAKER<br />

L1<br />

N<br />

GROUND<br />

TO SEPARATE<br />

FUSE/BREAKER.<br />

DISCONNECT ALL<br />

POLES.<br />

As the colors of the wires in the mains lead of the appliance may not correspond with the colored markings<br />

identifying the terminals in your plug, proceed as follows:<br />

• The wire which is colored green and yellow must be connected to the terminal in the plug which is marked with<br />

the letter E or by the earth ground symbol or colored green or green and yellow.<br />

• The wire colored blue must be connected to the terminal which is marked with the letter N or colored black.<br />

• The wire colored brown must be connected to the terminal which is marked with the letter L or colored red.