028 units, and one size for all others].)<br />

The contractor can order and<br />

install the roof curb early in the construction<br />

stage, before decisions on<br />

size requirements are made.<br />

All units feature roll-formed baserail<br />

design with forklift slots on 3 sides<br />

and rigging holes for easier maneuvering.<br />

The standard 48TJ004-006<br />

units have operating weights under<br />

500 lb and durable packaging<br />

protects all units during shipment<br />

and storage.<br />

The units can be easily converted<br />

from a vertical to a horizontal discharge<br />

configuration either by interchanging<br />

the panels supplied with the<br />

unit (004-014) or by using one of<br />

the horizontal supply/return curbs or<br />

the horizontal adapter (016-028).<br />

Convenient duct openings in the<br />

48TJ016-028 unit basepans permit<br />

side-by-side or concentric duct connections<br />

(see Application data section on<br />

page 64) without requiring internal<br />

unit modification.<br />

The non-corrosive sloped condensate<br />

pan permits either an external<br />

horizontal side condensate drain (outside<br />

the roof curb) or an internal<br />

vertical bottom drain (inside the roof<br />

curb). Both options require an external,<br />

field-supplied P-trap. Also, the condenser<br />

coil grille (available on the<br />

004-014 units as a field-installed accessory<br />

or a factory-installed option)<br />

provides a metal plate as an alternate<br />

location for the field-supplied disconnect,<br />

if desired.<br />

The 48TJ units were designed with<br />

service technicians in mind. The<br />

single-row condenser coils on the<br />

48TJ004-006 and 008 units simplify<br />

the cleaning process. The efficient<br />

in-shot burners and all ignition components<br />

are contained in an easily<br />

removable, compact assembly.<br />

The 48TJ004-014 units also have<br />

a standard filter access panel, which<br />

permits tool-less filter changes, even<br />

on units with horizontal economizers.<br />

Integrated gas unit controller<br />

(IGC) (004-014 only)<br />

All ignition components are contained<br />

in the compact IGC which is easily<br />

accessible for servicing. The IGC control<br />

board, designed and manufactured<br />

exclusively for <strong>Carrier</strong> rooftop<br />

units, provides built-in diagnostic<br />

capability. An LED (light-emitting diode)<br />

simplifies troubleshooting by<br />

2<br />

providing visual fault notification and<br />

system status confirmation.<br />

The IGC also contains an exclusive<br />

anti-cycle protection for gas heat<br />

operation. After 4 continuous cycles<br />

on the unit high-temperature limit<br />

switch, the gas heat operation is disabled,<br />

and an error code is issued.<br />

This feature greatly improves reliability<br />

of the rooftop unit.<br />

The IGC also contains burner control<br />

logic for accurate and dependable<br />

gas ignition. The LED is visible<br />

without removing the unit control box<br />

access panel. This LED faultnotification<br />

system reduces service<br />

person troubleshooting time and minimizes<br />

service costs. The IGC also<br />

maximizes heating efficiency by controlling<br />

evaporator-fan on and off<br />

delays.<br />

Simple electrical connections<br />

Terminal boards, located in the base<br />

unit control box, facilitate connections<br />

to room thermostat, outdoor thermostat(s),<br />

and economizer. Service<br />

panels are quickly removed, permitting<br />

easy servicing.<br />

Thru-the-bottom service connection<br />

capability (004-014) and thru-thecurb<br />

service connections (016-028)<br />

allow power and control wiring to<br />

be routed through unit basepan<br />

(004-014 units) or curb (016-028<br />

units), minimizing roof penetrations.<br />

Both power and control connections<br />

are made on the same side of<br />

the unit to simplify installation.<br />

In addition, color-coded wires permit<br />

easy tracing and diagnostics.<br />

Table of contents<br />

Proven compressor reliability<br />

Design techniques feature computerprogrammed<br />

balance between<br />

compressor, condenser, and evaporator.<br />

<strong>Carrier</strong>-specified hermetic<br />

(004-014 units) and semi-hermetic<br />

(016-028 units) compressors are<br />

equipped with compressor overcurrent<br />

and overtemperature protection to<br />

ensure dependability. Crankcase heaters<br />

(016-028 units) prevent refrigerant<br />

dilution of oil during off cycles and<br />

ensure proper lubrication at start-up<br />

to prolong compressor life. Crankcase<br />

heaters are not necessary on 004-<br />

014 units due to high-side crankcase<br />

design (007,014) and low refrigerant<br />

charge levels (004-014).<br />

The 48TJ016 unit (with factorysupplied<br />

unloading) is equipped with a<br />

thermostatic expansion valve to precisely<br />

adjust refrigerant flow during<br />

Stage 1 (unloaded) operation. All<br />

other 48TJ units have <strong>Carrier</strong>’s exclusive<br />

Acutrol metering device which<br />

precisely controls refrigerant flow,<br />

preventing slugging and flood-back,<br />

while maintaining optimum unit<br />

performance.<br />

Durable, dependable<br />

construction<br />

Designed for durability in any<br />

climate, the weather-resistant cabinets<br />

are constructed of galvanized<br />

steel and bonderized, and all exterior<br />

panels are coated with a prepainted<br />

baked enamel finish. The paint finish<br />

is non-chalking, and is capable of<br />

withstanding Federal test method<br />

Standard No. 141 (Method 6061)<br />

500-hour salt spray test. All internal<br />

Page<br />

Features/Benefits .........................................1-4<br />

Model Number Nomenclature .................................4<br />

ARI Capacity Ratings. ......................................5,6<br />

Physical <strong>Data</strong> ...........................................7-12<br />

Options and Accessories ...................................13-15<br />

Base Unit Dimensions ....................................16-20<br />

Accessory Dimensions ....................................21-24<br />

Selection Procedure ........................................24<br />

Performance <strong>Data</strong> .......................................25-52<br />

Electrical <strong>Data</strong> ..........................................53,54<br />

Typical Piping and Wiring ..................................55,56<br />

Typical Wiring Schematics .................................57,58<br />

Controls ..............................................59-63<br />

Application <strong>Data</strong> ........................................64,65<br />

Guide Specifications ......................................66-72