ACCUSENSOR II<br />

(004-014 Only)<br />

OUTDOOR TEMP. °F<br />

P P1<br />

OPEN<br />

%<br />

H<br />

U<br />

M<br />

I<br />

D<br />

I<br />

T<br />

Y<br />

60<br />

30<br />

10<br />

50<br />

55<br />

60 65 70 75<br />

80<br />

85<br />

DAMPER<br />

OPEN<br />

REV.<br />

T<br />

T1<br />

90<br />

70<br />

DAMPER<br />

CLOSED<br />

MINIMUM<br />

POSITION<br />

97-3672<br />

4<br />

3<br />

D C B A<br />

CW–SETPOINTS–CCW<br />

2<br />

RUSH AT 24VAC 3 mA MIN. AT 11 VDC<br />

1<br />

CONTACT RATINGS: 1.5A RUN, 3.5A IN<br />

CONTACTS SHOWN IN HIGH ENTHALPY<br />

OR UNPOWERED STATE<br />

5<br />

3<br />

2<br />

1<br />

S<br />

TR TR1<br />

24VAC<br />

ENTHALPY CONTROL<br />

D<br />

S O<br />

B<br />

C<br />

TR<br />

REV. B 198818A<br />

ACCUSENSOR III<br />

Accusensor economizer controls help provide efficient, economical economizer<br />

operation. Accusensor II solid-state enthalpy control includes the<br />

logic and one sensor to calculate both dry- and wet-bulb of the outdoor<br />

air to provide an accurate enthalpy reading on 004-014 units. It then decides<br />

when to energize the economizer based on this reading. The<br />

016-028 unit economizer provides the decision-making function internally,<br />

and requires one Accusensor III sensor for solid-state enthalpy sensing.<br />

A second Accusensor III sensor (required for all units for differential<br />

enthalpy sensing) compares outdoor temperature and humidity to returnair<br />

temperature and humidity and determines the most economical mixture<br />

of air (purchased in addition to enthalpy control [004-014] or to first<br />

solid-state enthalpy sensor [016-028] for differential enthalpy sensing).<br />

POWER EXHAUST (016-028 SHOWN)<br />

When used with accessory/optional economizer, the power exhaust<br />

accessory helps to relieve building over-pressurization.<br />

+<br />

FACTORY-INSTALLED APOLLO<br />

COMMUNICATING CONTROLS<br />

The Apollo direct digital controls are designed exclusively by<br />

<strong>Carrier</strong>, and are used to actively monitor and control all modes of<br />

operation as well as to monitor evaporator-fan status, filter status,<br />

supply-air temperature, outdoor-air temperature, and indoor-air quality.<br />

They are designed to work in conjunction with <strong>Carrier</strong> TEMP and<br />

VVT (variable volume/variable temperature) system thermostats.<br />

ELECTRONIC PROGRAMMABLE<br />

THERMOSTAT<br />

<strong>Carrier</strong>’s electronic programmable thermostat provides efficient temperature<br />

control by allowing you to program heating and cooling setbacks<br />

and setups with provisions for weekends and holidays. Accessory<br />

remote sensing package is also available to provide tamperproof<br />

control in high traffic spaces. Used in conjunction with factory-installed<br />

Apollo control, this thermostat provides a 5-minute recycle timer between<br />

modes of operation for short-cycle protection.<br />

THERMOSTAT<br />

Zone thermostat (24 v) provides one- or 2-stage cooling for control<br />

of unit. Matching subbases are available with or without tamperproof<br />

switches and automatic changeover.<br />