Options and accessories<br />

ITEM OPTION* ACCESSORY†<br />

Apollo Direct Digital Communicating Controls X<br />

Parablade Economizer (004-014 only) X<br />

Parablade Economizer with Power Exhaust (004-014) X<br />

Integrated Economizer (016-028) X X<br />

Durablade Integrated Economizer (004-014; Includes Hood) X X<br />

Manual Outdoor-Air Damper (ordered as standard on 016-028 units without<br />

optional economizer)<br />

X X<br />

Controls Upgrade Kit (004-014)** X X<br />

Condenser Coil Grille (004-014) X X<br />

Alternate Drive (008) X<br />

Alternate Motor and Drive (004-006, 012,014) X<br />

LP (Liquid Propane) Conversion Kit†† X<br />

Electronic Programmable Thermostat X<br />

25% Open Two-Position Damper X<br />

100% Open Two-Position Damper (004-014) X<br />

Barometric Relief Damper (016-028) X<br />

Roof Curbs (Vertical and Horizontal Discharge) X<br />

Horizontal Adapter (016-028) X<br />

Remote Control Panel X<br />

Thermostats and Subbases X<br />

Power Exhaust (016-028) X<br />

Low-Ambient Kits (016-028) X<br />

Winter Start Time-Delay Relay (020-028) X<br />

Motormaster Head Pressure Control (Speed Control) (004-014) X<br />

Motormaster II Head Pressure Control (Cycle Control) (004-014) X<br />

Motormaster III Head Pressure Control (Speed Control) (020-028) X<br />

Time Guard II Control Circuit X<br />

Thru-the-Bottom Service Connections (004-014) X<br />

Accusensor II Enthalpy Control (004-014) X<br />

Accusensor III Enthalpy Sensor X<br />

Condenser Coil Hail Guard Assembly (004-014) X<br />

Flue Shield (004-014) X<br />

NOx Reduction Kit (004-014) X<br />

Flue Discharge Deflector (004-014) X<br />

Fan/Filter Status (004-014) X<br />

Salt Spray Protection Grille (008-014) X<br />

*Factory installed.<br />

†Field installed.<br />

**Includes high-pressure,<br />

low-pressure/loss-of-charge,<br />

and freeze protection switches.<br />

††For 004-016, D020, D024, and D028 units.<br />

NOTE: Refer to 48/50TJ price pages or contact your local representative<br />

for accessory/and option package information.<br />

HEAD PRESSURE CONTROL<br />

The 48TJ004-014 and 024 standard units are designed to operate in cooling at outdoor temperatures<br />

down to 25 F, the standard 48TJ016 unit operates down to 40 F, the standard<br />

48TJ020 unit operates down to 35 F; and the standard 48TJ028 unit operates down to 48 F.<br />

With accessory Motormaster (48TJ004-014) control (condenser-fan speed modulation),<br />

Motormaster II control (condenser-fan cycling for units sizes 004-014), −20 F low-ambient kit<br />

(condenser fan sequencing for 48TJ016), or Motormaster III (48TJ020-028) control (condenser<br />

fan speed modulation) units can operate at outdoor temperatures down to −20 F.<br />

The head pressure controls, which mount in the condenser section, control the condenserfan<br />

motor to maintain correct condensing temperature. Refer to Price Pages or contact your<br />

local <strong>Carrier</strong> representative for appropriate accessory combinations for desired outdoor ambient<br />

temperature operation.<br />

Motormaster Control<br />

(004-014)<br />

Motormaster II Control<br />

(004-014)<br />

Motormaster III Control<br />

(020-028)<br />

13