Options and accessories<br />
ITEM OPTION* ACCESSORY†<br />
Apollo Direct Digital Communicating Controls X<br />
Parablade Economizer (004-014 only) X<br />
Parablade Economizer with Power Exhaust (004-014) X<br />
Integrated Economizer (016-028) X X<br />
Durablade Integrated Economizer (004-014; Includes Hood) X X<br />
Manual Outdoor-Air Damper (ordered as standard on 016-028 units without<br />
optional economizer)<br />
X X<br />
Controls Upgrade Kit (004-014)** X X<br />
Condenser Coil Grille (004-014) X X<br />
Alternate Drive (008) X<br />
Alternate Motor and Drive (004-006, 012,014) X<br />
LP (Liquid Propane) Conversion Kit†† X<br />
Electronic Programmable Thermostat X<br />
25% Open Two-Position Damper X<br />
100% Open Two-Position Damper (004-014) X<br />
Barometric Relief Damper (016-028) X<br />
Roof Curbs (Vertical and Horizontal Discharge) X<br />
Horizontal Adapter (016-028) X<br />
Remote Control Panel X<br />
Thermostats and Subbases X<br />
Power Exhaust (016-028) X<br />
Low-Ambient Kits (016-028) X<br />
Winter Start Time-Delay Relay (020-028) X<br />
Motormaster Head Pressure Control (Speed Control) (004-014) X<br />
Motormaster II Head Pressure Control (Cycle Control) (004-014) X<br />
Motormaster III Head Pressure Control (Speed Control) (020-028) X<br />
Time Guard II Control Circuit X<br />
Thru-the-Bottom Service Connections (004-014) X<br />
Accusensor II Enthalpy Control (004-014) X<br />
Accusensor III Enthalpy Sensor X<br />
Condenser Coil Hail Guard Assembly (004-014) X<br />
Flue Shield (004-014) X<br />
NOx Reduction Kit (004-014) X<br />
Flue Discharge Deflector (004-014) X<br />
Fan/Filter Status (004-014) X<br />
Salt Spray Protection Grille (008-014) X<br />
*Factory installed.<br />
†Field installed.<br />
**Includes high-pressure,<br />
low-pressure/loss-of-charge,<br />
and freeze protection switches.<br />
††For 004-016, D020, D024, and D028 units.<br />
NOTE: Refer to 48/50TJ price pages or contact your local representative<br />
for accessory/and option package information.<br />
HEAD PRESSURE CONTROL<br />
The 48TJ004-014 and 024 standard units are designed to operate in cooling at outdoor temperatures<br />
down to 25 F, the standard 48TJ016 unit operates down to 40 F, the standard<br />
48TJ020 unit operates down to 35 F; and the standard 48TJ028 unit operates down to 48 F.<br />
With accessory Motormaster (48TJ004-014) control (condenser-fan speed modulation),<br />
Motormaster II control (condenser-fan cycling for units sizes 004-014), −20 F low-ambient kit<br />
(condenser fan sequencing for 48TJ016), or Motormaster III (48TJ020-028) control (condenser<br />
fan speed modulation) units can operate at outdoor temperatures down to −20 F.<br />
The head pressure controls, which mount in the condenser section, control the condenserfan<br />
motor to maintain correct condensing temperature. Refer to Price Pages or contact your<br />
local <strong>Carrier</strong> representative for appropriate accessory combinations for desired outdoor ambient<br />
temperature operation.<br />
Motormaster Control<br />
(004-014)<br />
Motormaster II Control<br />
(004-014)<br />
Motormaster III Control<br />
(020-028)<br />
13