Consumeables Catalog - Lincoln Electric
Consumeables Catalog - Lincoln Electric Consumeables Catalog - Lincoln Electric
APPENDIX Stick Electrode Types of Coating & Current Mild Steel per AWS A5.1 TYPES OF COATING & CURRENT Digit Types of Coating Current 0 1 2 3 4 5 6 7 8 Low Alloy Steel per AWS A5.5 High cellulose sodium High cellulose potassium High titania sodium High titania potassium Iron powder, titania Low-hydrogen sodium Low-hydrogen potassium High iron oxide, iron powder Low-hydrogen potassium, iron powder 380 ı THE LINCOLN ELECTRIC COMPANY DC+ AC, DC± AC, DC- AC, DC+ AC, DC± DC+ AC, DC+ AC, DC± AC, DC± TYPES OF COATING Suffix %C %Mn %Si %P %S %Ni %Cr %Mo %V A1 B2 B3 C1 C3 D2 G (1) P1 P2 0.12 0.05 - 0.12 0.05 - 0.12 0.12 0.12 0.15 0.20 0.12 (1) Only one of the listed elements is required. 0.60 0.90 0.90 1.25 0.40 - 1.25 1.65 - 2.00 1.00 min. 1.20 0.90 - 1.70 0.40 0.80 0.80 0.80 0.80 0.80 0.80 min. 0.60 0.80 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 2.00 - 2.75 0.80 - 1.10 0.90 0.50 min. 1.00 1.00 1.00 - 1.50 2.00 - 2.50 0.15 0.30 min. 0.30 0.30 0.40 - 0.65 0.40 - 0.65 0.90 - 1.20 0.35 0.25 - 0.45 0.20 min. 0.50 0.50 0.05 0.10 min. 0.10 0.05 NOTE 1: Joining Electrodes, Non-Charpy V-Notch Rated These electrodes (see below) and others of the same AWS classification, are not required to deposit weld metal capable of delivering any minimum specified Charpy V-Notch (CVN) properties. It should not be used in applications where minimum specified CVN properties are required. Typical applications where minimum specified CVN properties are required include, but are not restricted to, bridges, pressure vessels, and buildings in seismic zones. The user of this product is responsible for determining whether minimum CVN properties are required for the specific application. Fleetweld ® 22 Fleetweld ® 37 Fleetweld ® 47 NOTE 2: Joining Electrodes, Non-Low Hydrogen These electrodes (see below) and others of the same AWS classification, are not required to deposit weld metal that is low in diffusible hydrogen. Therefore, these electrodes should not be used in applications where the hydrogen content of the weld metal is required to be controlled, such as applications that involve steels with higher carbon and alloy content, and higher strength. Fleetweld ® 5P Fleetweld ® 5P+ Fleetweld ® 35 Fleetweld ® 35LS Fleetweld ® 180 Fleetweld ® 37 Fleetweld ® 22 Shield-Arc ® 85 Shield-Arc ® 90 Shield-Arc ® HYP+ Fleetweld ® 47 Jetweld ® 1 Jetweld ® 2 Shield-Arc ® 70+ Pipeliner ® 6P+ Pipeliner ® 7P+ Piperliner ® 8P+
ASME BOILER & PRESSURE VESSEL CODE Section IX - F and A No.’s for Stick Electrode F Number (per ASME Section IX and AWS D1.1) AWS Classifications Product F-1 F-2 F-3 EXX20, EXX24, EXX27, EXX28, EXX20-X, EXX27-X EXX12, EXX13, EXX14, EXX13-X EXX10, EXX11, EXX10-X, EXX11-X F-4 EXX15, EXX16, EXX18, EXX45-X, EXX15-X, EXX16-X, EXX18-X APPENDIX Stick Electrode ASME Boiler & Pressure Vessel Code Fleetweld ® 22 Jetweld ® 2 Jetweld ® 1 Excalibur ® 7028 Fleetweld ® 37 Fleetweld ® 47 Fleetweld ® 5P Fleetweld ® 5P+ Pipeliner ® 6P+ Fleetweld ® 35 Fleetweld ® 35LS Fleetweld ® 180 Shield-Arc ® 85 Shield-Arc ® 70+ Shield-Arc ® 90 Shield-Arc ® HYP+ Pipeliner ® 7P+ Pipeliner ® 8P+ Jetweld ® LH-70 Jet-LH ® 78 Lincoln ® 7018AC Excalibur ® 7018 MR Excalibur ® 7018-1 MR Excalibur ® 7018-A1 MR Excalibur ® 8018-B2 MR Excalibur ® 8018-C1 MR Excalibur ® 8018-C3 MR Excalibur ® 9018-B3 MR Excalibur ® 9018M MR Excalibur ® 10018-D2 MR Excalibur ® 11018M MR Pipeliner ® 16P Pipeliner ® 18P Pipeliner ® 19P Pipeliner ® LH-D80 Pipeliner ® LH-D90 Pipeliner ® LH-D100 Weld Metal Analysis Classification (per ASME Section IX) – A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A2 – A11 – – – A1 A1 A1 A1 A1 A2 A3 A10 A10 A4 A10 A11 – A1 A10 A10 A1 – – WELDING CONSUMABLES CATALOG ı 381
- Page 332 and 333: BATCH | MIG (GMAW) WIRE SuperArc®
- Page 334 and 335: BATCH | MIG (GMAW) WIRE Blue Max®
- Page 336 and 337: BATCH | MIG (GMAW) WIRE Blue Max®
- Page 338 and 339: BATCH | MIG (GMAW) WIRE Blue Max®
- Page 340 and 341: BATCH | MIG (GMAW) WIRE Blue Max®
- Page 342 and 343: TIG (GTAW) CUT LENGTHS Lincoln® Lo
- Page 344 and 345: BATCH | TIG (GTAW) CUT LENGTHS Linc
- Page 346 and 347: BATCH | ORBITAL TIG (GTAW) WIRE Sup
- Page 348 and 349: BATCH | FLUX-CORED GAS-SHIELDED (FC
- Page 350 and 351: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 352 and 353: SUBMERGED ARC (SAW) FLUX AND WIRE C
- Page 354 and 355: SUBMERGED ARC (SAW) WIRE AND FLUX L
- Page 356 and 357: SUBMERGED ARC (SAW) WIRE AND FLUX L
- Page 358 and 359: PACKAGING Tubes, Cans & Cartons 5 l
- Page 360 and 361: PACKAGING Reels & Stem REELS Wire T
- Page 362 and 363: PACKAGING Spools A SPOOLS Wire Type
- Page 364 and 365: PACKAGING Coils, Boxes & Bags COILS
- Page 366 and 367: PACKAGING Drums & Pails DRUMS Wire
- Page 368 and 369: PACKAGING Storage & Handling Stick
- Page 370 and 371: PACKAGING Storage & Handling Metal-
- Page 372 and 373: PACKAGING Storage & Handling Submer
- Page 374 and 375: APPENDIX AWS Classification System
- Page 376 and 377: APPENDIX AWS Classification System
- Page 378 and 379: APPENDIX AWS Classification System
- Page 380 and 381: APPENDIX AWS Classification System
- Page 384 and 385: APPENDIX Submerged Arc Fluxes Flux
- Page 386 and 387: APPENDIX Submerged Arc Flux/Wire Se
- Page 388 and 389: APPENDIX Aluminum Typical Operating
- Page 390 and 391: APPENDIX Aluminum Typical Joint Des
- Page 392 and 393: APPENDIX Innershield® Wire Selecti
- Page 394 and 395: APPENDIX Agency Approvals NOTE: App
- Page 396 and 397: APPENDIX Agency Approvals NOTE: App
- Page 398 and 399: APPENDIX Agency Approvals NOTE: App
- Page 400 and 401: APPENDIX Agency Approvals NOTE: App
- Page 402 and 403: APPENDIX Agency Approvals NOTE: App
- Page 404 and 405: APPENDIX Agency Approvals NOTE: App
- Page 406 and 407: APPENDIX Safety Guidelines Diesel e
- Page 408 and 409: APPENDIX Safety Guidelines ARC RAYS
- Page 410 and 411: APPENDIX Safety Guidelines CYLINDER
- Page 412 and 413: APPENDIX Safety Guidelines The gase
- Page 414 and 415: APPENDIX Notes
- Page 416: THE LINCOLN ELECTRIC COMPANY 22801
APPENDIX<br />
Stick Electrode<br />
Types of Coating & Current<br />
Mild Steel per AWS A5.1<br />
TYPES OF COATING & CURRENT<br />
Digit Types of Coating Current<br />
0<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Low Alloy Steel per AWS A5.5<br />
High cellulose sodium<br />
High cellulose potassium<br />
High titania sodium<br />
High titania potassium<br />
Iron powder, titania<br />
Low-hydrogen sodium<br />
Low-hydrogen potassium<br />
High iron oxide, iron powder<br />
Low-hydrogen potassium, iron powder<br />
380 ı THE LINCOLN ELECTRIC COMPANY<br />
DC+<br />
AC, DC±<br />
AC, DC-<br />
AC, DC+<br />
AC, DC±<br />
DC+<br />
AC, DC+<br />
AC, DC±<br />
AC, DC±<br />
TYPES OF COATING<br />
Suffix %C %Mn %Si %P %S %Ni %Cr %Mo %V<br />
A1<br />
B2<br />
B3<br />
C1<br />
C3<br />
D2<br />
G (1)<br />
P1<br />
P2<br />
0.12<br />
0.05 - 0.12<br />
0.05 - 0.12<br />
0.12<br />
0.12<br />
0.15<br />
0.20<br />
0.12<br />
(1) Only one of the listed elements is required.<br />
0.60<br />
0.90<br />
0.90<br />
1.25<br />
0.40 - 1.25<br />
1.65 - 2.00<br />
1.00 min.<br />
1.20<br />
0.90 - 1.70<br />
0.40<br />
0.80<br />
0.80<br />
0.80<br />
0.80<br />
0.80<br />
0.80 min.<br />
0.60<br />
0.80<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
0.03<br />
2.00 - 2.75<br />
0.80 - 1.10<br />
0.90<br />
0.50 min.<br />
1.00<br />
1.00<br />
1.00 - 1.50<br />
2.00 - 2.50<br />
0.15<br />
0.30 min.<br />
0.30<br />
0.30<br />
0.40 - 0.65<br />
0.40 - 0.65<br />
0.90 - 1.20<br />
0.35<br />
0.25 - 0.45<br />
0.20 min.<br />
0.50<br />
0.50<br />
0.05<br />
0.10 min.<br />
0.10<br />
0.05<br />
NOTE 1: Joining Electrodes, Non-Charpy V-Notch Rated<br />
These electrodes (see below) and others of the same AWS classification, are not required to deposit weld metal capable of delivering any minimum specified<br />
Charpy V-Notch (CVN) properties. It should not be used in applications where minimum specified CVN properties are required. Typical applications where<br />
minimum specified CVN properties are required include, but are not restricted to, bridges, pressure vessels, and buildings in seismic zones. The user of this<br />
product is responsible for determining whether minimum CVN properties are required for the specific application.<br />
Fleetweld ® 22 Fleetweld ® 37 Fleetweld ® 47<br />
NOTE 2: Joining Electrodes, Non-Low Hydrogen<br />
These electrodes (see below) and others of the same AWS classification, are not required to deposit weld metal that is low in diffusible hydrogen. Therefore,<br />
these electrodes should not be used in applications where the hydrogen content of the weld metal is required to be controlled, such as applications that<br />
involve steels with higher carbon and alloy content, and higher strength.<br />
Fleetweld ® 5P<br />
Fleetweld ® 5P+<br />
Fleetweld ® 35<br />
Fleetweld ® 35LS<br />
Fleetweld ® 180<br />
Fleetweld ® 37<br />
Fleetweld ® 22<br />
Shield-Arc ® 85<br />
Shield-Arc ® 90<br />
Shield-Arc ® HYP+<br />
Fleetweld ® 47<br />
Jetweld ® 1<br />
Jetweld ® 2<br />
Shield-Arc ® 70+<br />
Pipeliner ® 6P+<br />
Pipeliner ® 7P+<br />
Piperliner ® 8P+