PIPELINER ® STICK (SMAW) ELECTRODE 18P Pipeliner ® Low Alloy, Low Hydrogen, Pipe • AWS E8018-G H4 Key Features Low hydrogen, vertical up capability on X70 grade pipe Charpy V-Notch impact toughness tested to -46°C (-50°F) Q2 Lot ® - Certificates showing actual deposit chemistry and mechanical properties available online 296 ı THE LINCOLN ELECTRIC COMPANY Typical Applications Fill and cap pass welding of up to X70 grade pipe Conformances AWS A5.5/A5.5M: 2006 ASME SFA-A5.5: ABS: Welding Positions All, except vertical down DIAMETERS / PACKAGING Diameter Length 10 lb (4.5 kg) Easy Open Can mm (in) in (mm) 30 lb (13.6 kg) Master Carton 3.2 (1/8) 4.0 (5/32) 14 (350) 14 (350) ED032620 ED032621 E8018-G H4 E8018-G H4 E8018-G MECHANICAL PROPERTIES (1) Yield Strength (2) Tensile Strength Elongation Charpy V-Notch J (ft•lbf) MPa (ksi) MPa (ksi) % @ -29°C (-20°F) @ -46°C (-50°F) Requirements - AWS E8018-G H4 460 (67) min. 550 (80) min. 19 min. Not Specified Not Specified Typical Results (3) - As-Welded 515-655 (75-95) 620-710 (90-103) 24-32 96-167 (71-123) 50-121 (37-89) DEPOSIT COMPOSITION (1) – As Required per AWS A5.5/A5.5M: 2006 %C %Mn %Si %P %S %Ni (4) Requirements - AWS E8018-G H4 Not Specified 1.00 min. 0.80 min. 0.03 max. 0.03 max. 0.50 min. Typical Results (3) 0.04-0.06 1.28-1.42 0.44-0.58 0.01-0.02 ≤ 0.01 0.76-0.85 %Cr (4) %Mo (4) %V (4) %Cu (4) TYPICAL OPERATING PROCEDURES Current (Amps) Polarity (5) 3.2 mm (1/8 in) 4.0 mm (5/32 in) DC+ 80-145 120-185 AC 90-155 130-195 Diffusible Hydrogen (mL/100g weld deposit) Requirements - AWS E8018-G H4 0.30 min. 0.20 min. 0.10 min. 0.20 min. 4.0 max. Typical Results (3) 0.04-0.06 0.17-0.39 < 0.01 < 0.02 1-4 (1) (2) (3) (4) Typical all weld metal. Measured with 0.2% offset. See test results disclaimer on pg. 16. In order to meet the alloy requirements of the “G” Designation, the undiluted weld metal shall have the minimum of at least one of the elements listed. (5) Preferred polarity is listed first.
Typical Applications Fill and cap pass welding on up to X70 grade pipe Conformances AWS A5.5/A5.5M: 2006 ASME SFA-A5.5: CWB/CSA W48-06: Welding Positions Vertical Down Pipe repair Hot tapping E8045-P2 H4R E8045-P2 H4R E8045-P2 H4R PIPELINER Pipeliner ® LH-D80 ® STICK (SMAW) ELECTRODE AWS E8045-P2 H4R • Low Alloy, Low Hydrogen, Pipe DIAMETERS / PACKAGING Diameter Length 10 lb (4.5 kg) Easy Open Can mm (in) mm (in) 30 lb (13.6 kg) Master Carton 3.2 (1/8) 4.0 (5/32) 4.5 (11/64) 350 (14) 350 (14) 350 (14) Low hydrogen, vertical down capability on up to X70 pipe High productivity Q2 Lot ® Key Features - Certificates showing actual deposit chemistry and mechanical properties available online Touch start tapered tip Meets H4R diffusible hydrogen level and moisture resistance ED032626 ED032627 ED032628 MECHANICAL PROPERTIES (1) – As Required per AWS A5.5/A5.5M: 2006 Yield Strength (2) Tensile Strength Elongation Charpy V-Notch J (ft•lbf) MPa (ksi) MPa (ksi) % @ -29°C (-20°F) @ -46°C (-50°F) Requirements - AWS E8045-P2 H4R 460 (67) min. 550 (80) min. 19 min. 27 (20) min. Not Specified Typical Results (3) - As-Welded 485-515 (70-75) 570-600 (83-87) 26-31 75-125 (55-92) 50-95 (37-70) DEPOSIT COMPOSITION (1) – As Required per AWS A5.5/A5.5M: 2006 %C %Mn %Si %P %S Requirements - AWS E8045-P2 H4R 0.12 max. 0.90-1.70 0.80 max. 0.03 max. 0.03 max. Typical Results (3) - As-Welded 0.04-0.06 1.10-1.25 0.35-0.50 ≤ 0.01 ≤ 0.01 TYPICAL OPERATING PROCEDURES Polarity 3.2 mm (1/8 in) Current (Amps) 4.0 mm (5/32 in) 4.5 mm (11/64 in) DC+ 120-170 170-250 200-300 (1) Typical all weld metal. (2) Measured with 0.2% offset. (3) See test results disclaimer on pg. 16. NOTE: This product contains micro-alloying elements. Additional information available on request. %Ni %Cr %Mo %V Diffusible Hydrogen (mL/100g weld deposit) Requirements - AWS E8045-P2 H4R 1.00 max. 0.20 max. 0.50 max. 0.05 max. 4.0 max. Typical Results (3) - As-Welded ≤ 0.04 ≤ 0.05 ≤ 0.02 ≤ 0.01 2-4 WELDING CONSUMABLES CATALOG ı 297
- Page 248 and 249: HARDFACING METAL-CORED GAS-SHIELDED
- Page 250 and 251: HARDFACING METAL-CORED (GMAW-C) WIR
- Page 252 and 253: HARDFACING FLUX-CORED SELF-SHIELDED
- Page 254 and 255: HARDFACING FLUX-CORED SELF-SHIELDED
- Page 256 and 257: HARDFACING FLUX-CORED SELF-SHIELDED
- Page 258 and 259: HARDFACING FLUX-CORED SELF-SHIELDED
- Page 260 and 261: HARDFACING FLUX-CORED SELF-SHIELDED
- Page 262 and 263: HARDFACING METAL-CORED SUBMERGED AR
- Page 264 and 265: HARDFACING METAL-CORED SUBMERGED AR
- Page 266 and 267: HARDFACING METAL-CORED SUBMERGED AR
- Page 268 and 269: HARDFACING METAL-CORED SUBMERGED AR
- Page 270 and 271: HARDFACING METAL-CORED SUBMERGED AR
- Page 272 and 273: HARDFACING METAL-CORED SUBMERGED AR
- Page 274 and 275: HARDFACING METAL-CORED SUBMERGED AR
- Page 276 and 277: HARDFACING METAL-CORED SUBMERGED AR
- Page 278 and 279: HARDFACING SUBMERGED ARC (SAW) FLUX
- Page 280 and 281: HARDFACING SUBMERGED ARC (SAW) FLUX
- Page 282 and 283: MIG (GMAW) WIRE SuperGlaze Aluminum
- Page 284 and 285: MIG (GMAW) WIRE SuperGlaze Aluminum
- Page 286 and 287: MIG (GMAW) WIRE SuperGlaze Aluminum
- Page 288 and 289: SuperGlaze ® MIG (GMAW) WIRE Alumi
- Page 290 and 291: TIG (GTAW) CUT LENGTHS SuperGlaze A
- Page 292 and 293: ALUMINUM & CAST IRON CONSUMABLES No
- Page 294 and 295: PIPELINER ® STICK (SMAW) ELECTRODE
- Page 296 and 297: PIPELINER ® STICK (SMAW) ELECTRODE
- Page 300 and 301: PIPELINER ® STICK (SMAW) ELECTRODE
- Page 302 and 303: PIPELINER ® STICK (SMAW) ELECTRODE
- Page 304 and 305: Pipeliner® Welding Positions All P
- Page 306 and 307: PIPELINER ® FLUX-CORED SELF-SHIELD
- Page 308 and 309: PIPELINER ® FLUX-CORED GAS-SHIELDE
- Page 310 and 311: PIPELINER ® FLUX-CORED GAS-SHIELDE
- Page 312 and 313: PIPELINER ® CONSUMABLES Electrode
- Page 314 and 315: PIPELINER ® CONSUMABLES Electrode
- Page 316 and 317: PIPELINER ® CONSUMABLES EN and ISO
- Page 318 and 319: Agency Approvals NOTE: Approvals ar
- Page 320 and 321: PIPELINER ® CONSUMABLES Notes 318
- Page 322 and 323: Power Generation & Nuclear Lincoln
- Page 324 and 325: BATCH | STICK (SMAW) ELECTRODE Exca
- Page 326 and 327: STICK (SMAW) ELECTRODE Excalibur®
- Page 328 and 329: STICK (SMAW) ELECTRODE Excalibur®
- Page 330 and 331: BATCH | MIG (GMAW) WIRE SuperArc®
- Page 332 and 333: BATCH | MIG (GMAW) WIRE SuperArc®
- Page 334 and 335: BATCH | MIG (GMAW) WIRE Blue Max®
- Page 336 and 337: BATCH | MIG (GMAW) WIRE Blue Max®
- Page 338 and 339: BATCH | MIG (GMAW) WIRE Blue Max®
- Page 340 and 341: BATCH | MIG (GMAW) WIRE Blue Max®
- Page 342 and 343: TIG (GTAW) CUT LENGTHS Lincoln® Lo
- Page 344 and 345: BATCH | TIG (GTAW) CUT LENGTHS Linc
- Page 346 and 347: BATCH | ORBITAL TIG (GTAW) WIRE Sup
PIPELINER ® STICK (SMAW) ELECTRODE<br />
18P<br />
Pipeliner ®<br />
Low Alloy, Low Hydrogen, Pipe • AWS E8018-G H4<br />
Key Features<br />
Low hydrogen, vertical up capability on<br />
X70 grade pipe<br />
Charpy V-Notch impact toughness tested<br />
to -46°C (-50°F)<br />
Q2 Lot ® - Certificates showing actual deposit<br />
chemistry and mechanical properties available<br />
online<br />
296 ı THE LINCOLN ELECTRIC COMPANY<br />
Typical Applications<br />
Fill and cap pass welding of up to X70 grade pipe<br />
Conformances<br />
AWS A5.5/A5.5M: 2006<br />
ASME SFA-A5.5:<br />
ABS:<br />
Welding Positions<br />
All, except vertical down<br />
DIAMETERS / PACKAGING<br />
Diameter Length 10 lb (4.5 kg) Easy Open Can<br />
mm (in) in (mm)<br />
30 lb (13.6 kg) Master Carton<br />
3.2 (1/8)<br />
4.0 (5/32)<br />
14 (350)<br />
14 (350)<br />
ED032620<br />
ED032621<br />
E8018-G H4<br />
E8018-G H4<br />
E8018-G<br />
MECHANICAL PROPERTIES (1)<br />
Yield Strength (2) Tensile Strength Elongation<br />
Charpy V-Notch<br />
J (ft•lbf)<br />
MPa (ksi) MPa (ksi) % @ -29°C (-20°F) @ -46°C (-50°F)<br />
Requirements - AWS E8018-G H4 460 (67) min. 550 (80) min. 19 min. Not Specified Not Specified<br />
Typical Results (3) - As-Welded 515-655 (75-95) 620-710 (90-103) 24-32 96-167 (71-123) 50-121 (37-89)<br />
DEPOSIT COMPOSITION (1) – As Required per AWS A5.5/A5.5M: 2006<br />
%C %Mn %Si %P %S %Ni (4)<br />
Requirements - AWS E8018-G H4 Not Specified 1.00 min. 0.80 min. 0.03 max. 0.03 max. 0.50 min.<br />
Typical Results (3) 0.04-0.06 1.28-1.42 0.44-0.58 0.01-0.02 ≤ 0.01 0.76-0.85<br />
%Cr (4) %Mo (4) %V (4) %Cu (4)<br />
TYPICAL OPERATING PROCEDURES<br />
Current (Amps)<br />
Polarity (5) 3.2 mm (1/8 in) 4.0 mm (5/32 in)<br />
DC+ 80-145 120-185<br />
AC 90-155 130-195<br />
Diffusible Hydrogen<br />
(mL/100g weld deposit)<br />
Requirements - AWS E8018-G H4 0.30 min. 0.20 min. 0.10 min. 0.20 min. 4.0 max.<br />
Typical Results (3) 0.04-0.06 0.17-0.39 < 0.01 < 0.02 1-4<br />
(1) (2) (3) (4) Typical all weld metal. Measured with 0.2% offset. See test results disclaimer on pg. 16. In order to meet the alloy requirements of the “G” Designation, the undiluted weld metal shall have the minimum of at least one of the elements listed.<br />