Consumeables Catalog - Lincoln Electric
Consumeables Catalog - Lincoln Electric Consumeables Catalog - Lincoln Electric
SUBMERGED ARC (SAW) FLUX Lincolnweld ® 800 Series Neutral Flux • EN 760 - S A FB 1 Key Features Carbon-neutral flux designed to provide excellent mechanical properties after extended stress-relief Industry leading low H4 diffusible hydrogen levels Smooth bead appearance and excellent slag release Moisture resistant packaging Typical Applications Offshore applications with extended post-weld heat treatment (PWHT) Quench and tempered steels such as AISI 4130, 8620, and similar chemistries 170 ı THE LINCOLN ELECTRIC COMPANY 812-SRC Recommended Wires For Low Alloy Steel Lincolnweld ® LA-84 Product Information Basicity Index: 2.2 Density: 1.3 g/cm3 Packaging 50 lb (22.7 kg) Plastic Bag FLUX COMPOSITION (1) %SiO2 %MnO %MgO %CaF2 Lincolnweld ® 812-SRC 16 3 30 19 ED034171 %Na 2 O %Al 2 O 3 %CaO % Metal Alloys Lincolnweld ® 812-SRC 2 22 4 3 max. AWS TEST RESULTS (1) Flux/Wire Combination Weld Condition Yield Strength (2) Tensile Strength Elongation Charpy V-Notch AWS Classification MPa (ksi) MPa (ksi) (%) J (ft•lbf) @ °C (°F) (A5.17/A5.23) LA-84 As-welded 680 (98) 790 (114) 24 87 (64) -51 (-60) F10A6-EF3-F3-H4 (1) See test results disclaimer on pg. 16. (2) Measured with 0.2% offset. NOTE 1: For the most up-to-date AWS certificates of conformances please visit www.lincolnelectric.com
Recommended Wires For Mild Steel Lincolnweld ® L-50 ® , L-61 ® , LA-71 For Low Alloy Steel Lincolnweld ® LA-75, LA-85, LA-93, LA-100 Product Information Basicity Index: 1.1 Density: 1.4 g/cm3 AWS D1.8 and FEMA 353 Approved when paired with the following wires: • 3/32 in (2.4 mm) Lincolnweld ® L-56 ® • 1/8 in (3.2 mm) Lincolnweld ® L-61 ® • 1/8 in (3.2 mm) Lincolnweld ® LA-85 Packaging 50 lb (22.7 kg) Bag ED022412 FLUX COMPOSITION (1) AWS TEST RESULTS (1) Flux/Wire Combination L-50 ® L-61 ® LA-71 LA-71 LA-75 LA-75 LA-85 LA-85 LA-93 LA-100 Weld Condition As-welded As-welded As-welded Stress-relieved (3) As-welded Stress-relieved (3) As-welded Stress-relieved (3) Stress-relieved (4) As-welded SUBMERGED ARC (SAW) FLUX Lincolnweld ® Typical Applications Single and multiple pass welding 960® EN 760 – S A AB 1 • Special Neutral Flux Low cost, general purpose flux designed to weld butt joints and both single and multiple pass fillets Recommended for automatic and semiautomatic submerged arc welding A versatile, cost-effective flux that can be used with many alloy systems Can be used on A588 weathering steels when combined with Lincolnweld ® Key Features LA-75 Fillet and butt welds with unlimited plate thickness Can weld steel with heavy scale or rust when used with Lincolnweld ® L-50 ® wire Weathering steels when used with Lincolnweld ® LA-75 wire %SiO 2 %MnO %MgO %CaF 2 %Na 2 O %Al 2 O 3 %CaO %TiO 2 % Metal Alloys Lincolnweld ® 960 ® 21 10 21 10 2 31 1 1 3 max. Yield Strength (2) Tensile Strength Elongation Charpy V-Notch AWS Classification MPa (ksi) MPa (ksi) (%) J (ft•lbf) @ °C (°F) (A5.17/A5.23) 460 (66) 420 (61) 460 (66) 420 (61) 480 (69) 420 (61) 520 (76) 500 (73) 580 (84) 680 (99) 570 (83) 520 (75) 570 (82) 540 (79) 600 (87) 550 (80) 640 (93) 610 (88) 680 (98) 740 (108) (1) See test results disclaimer on pg. 16. (2) Measured with 0.2% offset. (3) Stress-relieved for 1 hour at 621°C (1150°F). (4) Stress-relieved for 1 hour at 691°C (1275°F). NOTE: For the most up-to-date AWS certificates of conformances please visit www.lincolnelectric.com 27 32 29 31 30 29 24 25 22 25 58 (43) 125 (92) 44 (32) 89 (66) 76 (56) 53 (39) 57 (42) 39 (29) 65 (48) 33 (24) -29 (-20) -29 (-20) -29 (-20) -29 (-20) -29 (-20) -51 (-60) -29 (-20) -46 (-50) -18 (0) -40 (-40) F7A2-EM13K-H8 F7A2-EM12K-H8 F7A2-EM14K-H8 F7P2-EM14K-H8 F8A2-ENi1K-Ni1-H8 F7P6-ENi1K-Ni1-H8 F8A2-ENi5-G-H8 F7P5-ENi5-G-H8 F9P0-EB3R-G-H8 F10A4-EM2-G-H8 Structural Welding Code Seismic Supplement WELDING CONSUMABLES CATALOG ı 171
- Page 122 and 123: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 124 and 125: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 126 and 127: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 128 and 129: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 130 and 131: Structural Welding Code Seismic Sup
- Page 132 and 133: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 134 and 135: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 136 and 137: Structural Welding Code Seismic Sup
- Page 138 and 139: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 140 and 141: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 142 and 143: Structural Welding Code Seismic Sup
- Page 144 and 145: Structural Welding Code Seismic Sup
- Page 146 and 147: Structural Welding Code Seismic Sup
- Page 148 and 149: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 150 and 151: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 152 and 153: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 154 and 155: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 156 and 157: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 158 and 159: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 160 and 161: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 162 and 163: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 164 and 165: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 166 and 167: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 168 and 169: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 170 and 171: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 174 and 175: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 176 and 177: Lincolnweld ® Features the chemica
- Page 178 and 179: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 180 and 181: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 182 and 183: SUBMERGED ARC (SAW) ELECTRODE Linco
- Page 184 and 185: SUBMERGED ARC (SAW) ELECTRODE Linco
- Page 186 and 187: SUBMERGED ARC (SAW) ELECTRODE Linco
- Page 188 and 189: SUBMERGED ARC (SAW) ELECTRODE Linco
- Page 190 and 191: SUBMERGED ARC (SAW) ELECTRODE Linco
- Page 192 and 193: SUBMERGED ARC (SAW) ELECTRODE Linco
- Page 194 and 195: SUBMERGED ARC (SAW) CONSUMABLES Not
- Page 196 and 197: STICK (SMAW) ELECTRODE Excalibur®
- Page 198 and 199: STICK (SMAW) ELECTRODE Excalibur ®
- Page 200 and 201: STICK (SMAW) ELECTRODE Excalibur ®
- Page 202 and 203: STICK (SMAW) ELECTRODE Excalibur ®
- Page 204 and 205: STICK (SMAW) ELECTRODE Excalibur ®
- Page 206 and 207: MIG (GMAW) WIRE Blue Max® Stainles
- Page 208 and 209: MIG (GMAW) WIRE Blue Max® Stainles
- Page 210 and 211: MIG (GMAW) WIRE Blue Max ® Stainle
- Page 212 and 213: MIG (GMAW) WIRE Blue Max® Stainles
- Page 214 and 215: MIG (GMAW) WIRE Blue Max® Stainles
- Page 216 and 217: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 218 and 219: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 220 and 221: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
Recommended Wires<br />
For Mild Steel<br />
<strong>Lincoln</strong>weld ® L-50 ® , L-61 ® , LA-71<br />
For Low Alloy Steel<br />
<strong>Lincoln</strong>weld ® LA-75, LA-85, LA-93, LA-100<br />
Product Information<br />
Basicity Index: 1.1<br />
Density: 1.4 g/cm3 AWS D1.8 and FEMA 353<br />
Approved when paired with the following wires:<br />
• 3/32 in (2.4 mm) <strong>Lincoln</strong>weld ® L-56 ®<br />
• 1/8 in (3.2 mm) <strong>Lincoln</strong>weld ® L-61 ®<br />
• 1/8 in (3.2 mm) <strong>Lincoln</strong>weld ® LA-85<br />
Packaging<br />
50 lb (22.7 kg) Bag ED022412<br />
FLUX COMPOSITION (1)<br />
AWS TEST RESULTS (1)<br />
Flux/Wire<br />
Combination<br />
L-50 ®<br />
L-61 ®<br />
LA-71<br />
LA-71<br />
LA-75<br />
LA-75<br />
LA-85<br />
LA-85<br />
LA-93<br />
LA-100<br />
Weld<br />
Condition<br />
As-welded<br />
As-welded<br />
As-welded<br />
Stress-relieved (3)<br />
As-welded<br />
Stress-relieved (3)<br />
As-welded<br />
Stress-relieved (3)<br />
Stress-relieved (4)<br />
As-welded<br />
SUBMERGED ARC (SAW) FLUX<br />
<strong>Lincoln</strong>weld ®<br />
Typical Applications<br />
Single and multiple pass welding<br />
960®<br />
EN 760 – S A AB 1 • Special Neutral Flux<br />
Low cost, general purpose flux designed to<br />
weld butt joints and both single and multiple<br />
pass fillets<br />
Recommended for automatic and<br />
semiautomatic submerged arc welding<br />
A versatile, cost-effective flux that can be<br />
used with many alloy systems<br />
Can be used on A588 weathering steels<br />
when combined with <strong>Lincoln</strong>weld ® Key Features<br />
LA-75<br />
Fillet and butt welds with unlimited plate thickness<br />
Can weld steel with heavy scale or rust<br />
when used with <strong>Lincoln</strong>weld ® L-50 ® wire<br />
Weathering steels when used with<br />
<strong>Lincoln</strong>weld ® LA-75 wire<br />
%SiO 2 %MnO %MgO %CaF 2 %Na 2 O %Al 2 O 3 %CaO %TiO 2 % Metal Alloys<br />
<strong>Lincoln</strong>weld ® 960 ® 21 10 21 10 2 31 1 1 3 max.<br />
Yield Strength (2) Tensile Strength Elongation Charpy V-Notch AWS Classification<br />
MPa (ksi) MPa (ksi) (%) J (ft•lbf) @ °C (°F) (A5.17/A5.23)<br />
460 (66)<br />
420 (61)<br />
460 (66)<br />
420 (61)<br />
480 (69)<br />
420 (61)<br />
520 (76)<br />
500 (73)<br />
580 (84)<br />
680 (99)<br />
570 (83)<br />
520 (75)<br />
570 (82)<br />
540 (79)<br />
600 (87)<br />
550 (80)<br />
640 (93)<br />
610 (88)<br />
680 (98)<br />
740 (108)<br />
(1) See test results disclaimer on pg. 16. (2) Measured with 0.2% offset. (3) Stress-relieved for 1 hour at 621°C (1150°F). (4) Stress-relieved for 1 hour at 691°C (1275°F).<br />
NOTE: For the most up-to-date AWS certificates of conformances please visit www.lincolnelectric.com<br />
27<br />
32<br />
29<br />
31<br />
30<br />
29<br />
24<br />
25<br />
22<br />
25<br />
58 (43)<br />
125 (92)<br />
44 (32)<br />
89 (66)<br />
76 (56)<br />
53 (39)<br />
57 (42)<br />
39 (29)<br />
65 (48)<br />
33 (24)<br />
-29 (-20)<br />
-29 (-20)<br />
-29 (-20)<br />
-29 (-20)<br />
-29 (-20)<br />
-51 (-60)<br />
-29 (-20)<br />
-46 (-50)<br />
-18 (0)<br />
-40 (-40)<br />
F7A2-EM13K-H8<br />
F7A2-EM12K-H8<br />
F7A2-EM14K-H8<br />
F7P2-EM14K-H8<br />
F8A2-ENi1K-Ni1-H8<br />
F7P6-ENi1K-Ni1-H8<br />
F8A2-ENi5-G-H8<br />
F7P5-ENi5-G-H8<br />
F9P0-EB3R-G-H8<br />
F10A4-EM2-G-H8<br />
Structural Welding Code<br />
Seismic Supplement<br />
WELDING CONSUMABLES CATALOG ı 171