Structural Welding Code Seismic Supplement UltraCore® Typical Applications Structural fabrication Heavy equipment Shipbuilding 70C Mild Steel, Flat & Horizontal • AWS E70T-1C-H8, E70T-9C-H8 Key Features High deposition in the flat and horizontal positions Low fume generation rates FLUX-CORED GAS-SHIELDED (FCAW-G) WIRE Designed for welding with 100% CO 2 shielding gas Premium arc performance and bead appearance DIAMETERS / PACKAGING Diameter 50 lb (22.7 kg) in (mm) Coil 1/16 (1.6) ED032978 5/64 (2.0) ED032977 3/32 (2.4) ED032941 134 ı THE LINCOLN ELECTRIC COMPANY Conformances AWS A5.20/A5.20M: ASME SFA-A5.20: ABS: CWB/CSA W48-06: EN ISO 17632-B: FEMA 353 AWS D1.8 Welding Positions Flat & Horizontal Shielding Gas 100% CO 2 Flow Rate: 40-55 CFH 500 lb (227 kg) Accu-Trak ® Drum ED033064 E70T-1C-H8, E70T-9C, E70T-9C-H8 E70T-1C-H8, E70T-9C, E70T-9C-H8 2YSA H10 E492T-9 H8 T493T1-0CA-H10 500 lb (227 kg) Speed-Feed ® Drum ED033065 ED033066
MECHANICAL PROPERTIES (1) – As Required per AWS A5.20/A5.20M Requirements (4) AWS E70T-1C-H8 & E70T-9C-H8 Yield Strength (2) Tensile Charpy V-Notch Strength Elongation J (ft•lbf) MPa (ksi) MPa (ksi) % @ -18°C (0°F) @ -29°C (-20°F) 400 (58) min. 480-655 (70-95) 22 min. DEPOSIT COMPOSITION (1) – As Required per AWS A5.20/A5.20M %C %Mn %Si %S %P 27 (20) min. 27 (20) min. Typical Results (3) As-Welded with 100% CO 2 485-520 (70-75) 555-590 (81-86) 28-30 47-72 (35-53) 28-47 (21-35) Diffusible Hydrogen (mL/100g weld deposit) Requirements (4) AWS E70T-1C-H8 & E70T-9C-H8 0.12 max. 1.75 max. 0.90 max. 0.03 max. 0.03 max. 8.0 max. Typical Results (3) As-Welded with 100% CO 2 0.04-0.05 1.46-1.59 0.54-0.59 ≤ 0.01 ≤ 0.01 5-8 TYPICAL OPERATING PROCEDURES – Flat & Horizontal Diameter, Polarity Shielding Gas 1/16 in (1.6 mm), DC+ 100% CO 2 5/64 in (2.0 mm), DC+ 100% CO 2 3/32 in (2.4 mm), DC+ 100% CO 2 CTWD (5) mm (in) 25 (1) 25 (1) 25 (1) 31 (1 1/4) Wire Feed Speed Voltage Approx. Current Melt-Off Rate Deposition Rate Efficiency m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%) 3.2 5.1 6.4 7.6 9.5 3.2 4.4 5.7 6.4 7.6 8.3 3.2 5.1 6.4 7.6 8.3 (125) (200) (250) (300) (375) (125) (175) (225) (250) (300) (325) (125) (200) (250) (300) (325) 23-27 24-28 25-30 27-31 28-32 23-27 24-29 25-30 26-32 27-33 29-34 26-33 27-34 29-35 31-37 32-38 170 225 260 280 320 230 305 365 385 420 450 350 500 570 630 720 (1) Typical all weld metal. (2) Measured with 0.2% offset. (3) See test results disclaimer on pg. 16. (4) As-Welded with 100% CO2 . (5) To estimate ESO, subtract 1/4 in (6.0 mm) from CTWD. FLUX-CORED GAS-SHIELDED (FCAW-G) WIRE 2.4 3.8 4.8 5.7 7.1 3.8 5.4 6.8 7.7 9.0 9.9 5.4 8.6 10.6 13.1 14.3 (5.3) (8.4) (10.5) (12.6) (15.7) (8.4) (11.8) (15.0) (16.9) (19.8) (21.7) (11.9) (19.0) (23.3) (28.8) (31.5) UltraCore ® 2.1 3.2 4.1 4.9 6.1 3.2 4.6 5.9 6.5 7.8 8.7 4.7 7.6 9.4 11.4 12.4 (4.7) (7.1) (9.0) (10.8) (13.5) (7.1) (10.1) (13.0) (14.3) (17.2) (19.0) (10.3) (16.7) (20.8) (25.1) (27.2) 84 - 89 84 - 88 87 - 89 70C (AWS E70T-1C-H8, E70T-9C-H8) WELDING CONSUMABLES CATALOG ı 135
- Page 86 and 87: Structural Welding Code Seismic Sup
- Page 88 and 89: FLUX-CORED SELF-SHIELDED (FCAW-S) W
- Page 90 and 91: FLUX-CORED SELF-SHIELDED (FCAW-S) W
- Page 92 and 93: FLUX-CORED SELF-SHIELDED (FCAW-S) W
- Page 94 and 95: Structural Welding Code Seismic Sup
- Page 96 and 97: Structural Welding Code Seismic Sup
- Page 98 and 99: Structural Welding Code Seismic Sup
- Page 100 and 101: Structural Welding Code Seismic Sup
- Page 102 and 103: FLUX-CORED SELF-SHIELDED (FCAW-S) W
- Page 104 and 105: FLUX-CORED SELF-SHIELDED (FCAW-S) W
- Page 106 and 107: FLUX-CORED SELF-SHIELDED (FCAW-S) W
- Page 108 and 109: Structural Welding Code Seismic Sup
- Page 110 and 111: Structural Welding Code Seismic Sup
- Page 112 and 113: Structural Welding Code Seismic Sup
- Page 114 and 115: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 116 and 117: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 118 and 119: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 120 and 121: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 122 and 123: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 124 and 125: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 126 and 127: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 128 and 129: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 130 and 131: Structural Welding Code Seismic Sup
- Page 132 and 133: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 134 and 135: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 138 and 139: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 140 and 141: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 142 and 143: Structural Welding Code Seismic Sup
- Page 144 and 145: Structural Welding Code Seismic Sup
- Page 146 and 147: Structural Welding Code Seismic Sup
- Page 148 and 149: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 150 and 151: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 152 and 153: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 154 and 155: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 156 and 157: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 158 and 159: FLUX-CORED GAS-SHIELDED (FCAW-G) WI
- Page 160 and 161: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 162 and 163: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 164 and 165: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 166 and 167: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 168 and 169: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 170 and 171: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 172 and 173: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 174 and 175: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 176 and 177: Lincolnweld ® Features the chemica
- Page 178 and 179: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 180 and 181: SUBMERGED ARC (SAW) FLUX Lincolnwel
- Page 182 and 183: SUBMERGED ARC (SAW) ELECTRODE Linco
- Page 184 and 185: SUBMERGED ARC (SAW) ELECTRODE Linco
Structural Welding Code<br />
Seismic Supplement<br />
UltraCore®<br />
Typical Applications<br />
Structural fabrication<br />
Heavy equipment<br />
Shipbuilding<br />
70C<br />
Mild Steel, Flat & Horizontal • AWS E70T-1C-H8, E70T-9C-H8<br />
Key Features<br />
High deposition in the flat and horizontal positions<br />
Low fume generation rates<br />
FLUX-CORED GAS-SHIELDED (FCAW-G) WIRE<br />
Designed for welding with 100% CO 2<br />
shielding gas<br />
Premium arc performance and bead appearance<br />
DIAMETERS / PACKAGING<br />
Diameter 50 lb (22.7 kg)<br />
in (mm)<br />
Coil<br />
1/16 (1.6)<br />
ED032978<br />
5/64 (2.0)<br />
ED032977<br />
3/32 (2.4)<br />
ED032941<br />
134 ı THE LINCOLN ELECTRIC COMPANY<br />
Conformances<br />
AWS A5.20/A5.20M:<br />
ASME SFA-A5.20:<br />
ABS:<br />
CWB/CSA W48-06:<br />
EN ISO 17632-B:<br />
FEMA 353<br />
AWS D1.8<br />
Welding Positions<br />
Flat & Horizontal<br />
Shielding Gas<br />
100% CO 2<br />
Flow Rate: 40-55 CFH<br />
500 lb (227 kg)<br />
Accu-Trak ® Drum<br />
ED033064<br />
E70T-1C-H8, E70T-9C,<br />
E70T-9C-H8<br />
E70T-1C-H8, E70T-9C,<br />
E70T-9C-H8<br />
2YSA H10<br />
E492T-9 H8<br />
T493T1-0CA-H10<br />
500 lb (227 kg)<br />
Speed-Feed ® Drum<br />
ED033065<br />
ED033066