Manual<br />
Digistrob RDS 30<br />
5 Description of functions on the front panel<br />
5.1 Display<br />
The DIGISTROB RDS 30 shows the measured value with an accuracy of ± 1 digit on<br />
the 5-digit LED display 6. Depending on the selected range, the indication is direct in<br />
2 pulses/minute or RPM<br />
measuring range: 150 - 22000min -1<br />
measuring accuracy: ± 1min -1<br />
3 Pulses/sec. or frequency in Hz<br />
measuring range: 2,5 - 360Hz<br />
measuring accuracy: ±0,3Hz<br />
4 Time in ms between two pulses or period interval<br />
measuring range: 2,5 - 400ms<br />
measuring accuracy: ±0,2ms<br />
When these ranges are exceeded or fallen short of, this is indicated with signal LED 5 and<br />
the LED display 6 extinguishes.<br />
The same happens when the input signals fluctuate strongly during the synchronization time<br />
(a few seconds) of the PLL (Phase Locked Loop) or if they fail altogether (range fallen short<br />
of).<br />
Thus when the DIGISTROB RDS 30 is switched on by means of the power switch 1 and the<br />
input signals are not yet available or fluctuate strongly, the LED display 6 remains dark.<br />
In this event only the indication LED 5 lights up.<br />
5.2 External triggering<br />
The DIGISTROB RDS 30 can be triggered from outside in various manners. The following<br />
possibilities of external triggering can be set by means of the the keys 7 - 11:<br />
7 triggering synchronous to mains<br />
8 via photo-electric pick-up with bright markings on the object<br />
9 via photo-electric pick-up with dark markings on the object<br />
10 via inductive pick-up with gear wheels<br />
11 via inductive pick-up with aperture discs<br />
Triggering is also possible by means of external voltage sources or<br />
by means of Visolux pick-up circuits.<br />
In this case the input circuit Ind A 10 / Inductive B 11 is particularly<br />
suited for fast signals with little disturbance. But this method of<br />
triggering is not suitable for very slow signals.<br />
For very slow signals or such with a high disturbance factor it is recommended to lead the<br />
triggering via Photoelectric A 8 / Photoelectric B 9.<br />
But this triggering variant is again not suited for fast signals with fluctuating aplitude.<br />
A wide selection of optical and inductive pick-ups and external voltage sources can be<br />
connected to the "trigger" socket 22.<br />
Page 6/20, Manual