Manual Digistrob RDS 30 9 DIGISTROB RDS 30, Technical Data 9.1 General Operating voltage: 230V AC ±10%, 50 - 60Hz, (115V AC upon request) Power requirement: 50VA max. Operating temperature: 0 - 40°C Flash frequency: 3-333Hz / continuous (180-20'000min -1 ) max: 415Hz, 1 min. (25'000min -1 ) Control unit: Alum. housing with handle Hand lamp: plastic (extra light - temperature resistant) Handle with camera thread 9.2 Dimensions and weight Dimensions hand lamp: 105 x 220 x185 (H/W/D in mm) control unit: 100 x 285 x 300 (H/W/D in mm) Weight hand lamp: 0.850kg Weight control unit: 3.6kg 9.3 Measuring range and display Speed (RPM): 150 – 22'000min -1 , ±1min -1 Frequency (Hz): 2,5 – 360Hz, ± 0.3Hz Period (ms): 2,5 – 400ms, ± 0.2ms 9.4 Internal Flash triggering from internal oscillator, adjustable course and fine by means of double control knob, adjustment with step-down Range I: 200 – 4000min -1 3 – 66Hz 300 – 15ms Range II: 1000 – 20000min -1 16 – 333Hz 60 – 3ms 9.5 External • Synchronous to mains • Optical and inductive p i c k - u p s • Logic signal • Alternating current Bright and dark markings (optical) as well as gear wheels or perforated disks (inductive) Input divider for frequency division Emitter voltage: 100mV - 20V AC/DC Divider range: 1 + 999, BCD coding switch Page 13/20, Manual
Manual Digistrob RDS 30 9.6 Monitor socket Frequency output: logic signal, 15V / 40mA, temporarily short circuit proof Voltage output: 30mV / Hz, linearity ± 5%, temporarily short circuit proof Gate input: For external driving of the hand lamp (switching ON/OFF or single flash triggering) Contact or logic signal (+15V / 0V) normally open/normally closed or polarity switch 9.7 Selector switch "MODE“ 1 Phase shifter by-pass, effects a constant delay interval between trigger pulse and flash 2 Single flash setting for driving via gate 3 Polarity setting (high/low - active) of the gate 4 Has no function 10 Accessories Examples: 10.1 Table-top stand – TS ∅ 150 mm, with threaded hole M8 10.2 Table-rod clamp – TRK Clamping width 40 mm, with threaded hole M8 Page 14/20, Manual
- Page 1 and 2: OEG AG Staudnerbachstrasse 1 CH-947
- Page 3 and 4: Manual Digistrob RDS 30 1 Strobosco
- Page 5 and 6: Manual Digistrob RDS 30 3 Hand lamp
- Page 7 and 8: Manual Digistrob RDS 30 5 Descripti
- Page 9 and 10: Manual Digistrob RDS 30 5.5 Phase s
- Page 11 and 12: Manual Digistrob RDS 30 6.4 Mode se
- Page 13: Manual Digistrob RDS 30 8 Maintenan
- Page 17 and 18: Manual Digistrob RDS 30 10.8 Photo-
- Page 19 and 20: Manual Digistrob RDS 30 11.2 Extern
- Page 21: Manual Digistrob RDS 30 for Visolux
Manual<br />
Digistrob RDS 30<br />
9 DIGISTROB RDS 30, Technical Data<br />
9.1 General<br />
Operating voltage: 230V AC ±10%, 50 - 60Hz, (115V AC upon request)<br />
Power requirement: 50VA max.<br />
Operating temperature: 0 - 40°C<br />
Flash frequency: 3-333Hz / continuous (180-20'000min -1 )<br />
max: 415Hz, 1 min. (25'000min -1 )<br />
Control unit: Alum. housing with handle<br />
Hand lamp: plastic (extra light - temperature resistant)<br />
Handle with camera thread<br />
9.2 Dimensions and weight<br />
Dimensions hand lamp: 105 x 220 x185 (H/W/D in mm)<br />
control unit: 100 x 285 x 300 (H/W/D in mm)<br />
Weight hand lamp: 0.850kg<br />
Weight control unit: 3.6kg<br />
9.3 Measuring range and display<br />
Speed (RPM): 150 – 22'000min -1 , ±1min -1<br />
Frequency (Hz): 2,5 – 360Hz, ± 0.3Hz<br />
Period (ms): 2,5 – 400ms, ± 0.2ms<br />
9.4 Internal<br />
Flash triggering from internal oscillator, adjustable course and fine by means of double<br />
control knob, adjustment with step-down<br />
Range I: 200 – 4000min -1<br />
3 – 66Hz<br />
300 – 15ms<br />
Range II: 1000 – 20000min -1<br />
16 – 333Hz<br />
60 – 3ms<br />
9.5 External<br />
• Synchronous to mains<br />
• Optical and inductive p i c k - u p s<br />
• Logic signal<br />
• Alternating current<br />
Bright and dark markings (optical) as well as gear wheels or perforated disks (inductive)<br />
Input divider for frequency division<br />
Emitter voltage: 100mV - 20V AC/DC<br />
Divider range: 1 + 999, BCD coding switch<br />