Manual<br />

Digistrob RDS 30<br />

6 Description of functions on the rear side<br />

6.1 Connection of lamp<br />

The hand lamp is connected and locked at socket 21.<br />

6.2 External trigger input<br />

If the RDS 30 has to be triggered externally, the external<br />

trigger signal input is connected to the trigger input (socket 22) and the adequate input circuit<br />

is selected at the control elements 8-12 at the front. With mains-synchronous triggering 7<br />

connection for signal at the trigger input 22 is not required.<br />

All supplied pick-ups (see accessories page 16) can be<br />

connected directly to the "trigger" socket 22. For other<br />

emitters and for external voltage sources the wiring<br />

examples on pages 18-20 should be observed.<br />

Allocation of pins and input wiring can be seen on the<br />

diagram on page 17 and the legend on page 4.<br />

6.3 Monitor socket<br />

Pulse output<br />

The RDS 30 has a pulse output as well as an analog output. The 15V/40mA logic signal of<br />

the pulse output at the monitor socket 23 pin 1/2 is also stepped down at the ratio of the input<br />

divider 12, in accordance with the input pulses. Furthermore, the pulse output is temporarily<br />

short-circuit proof.<br />

Analog output<br />

The analog output is taken from pin 5/2 of socket 23, in form of a frequency proportional<br />

voltage. The voltage is 30 mV/Hz or 500 µV/min -1 and has a linearity of ± 5%.<br />

The analog output is also temporarily short-circuit proof, but has no offset balancing.<br />

External gate input<br />

The hand lamp can also be driven externally via the gate input (monitor socket 23, pin 4/2). In<br />

this case the polarity of the gate (high/low - active) can be selected with the selector switch<br />

"mode 3" 24.<br />