Manual<br />
Digistrob RDS 30<br />
6 Description of functions on the rear side<br />
6.1 Connection of lamp<br />
The hand lamp is connected and locked at socket 21.<br />
6.2 External trigger input<br />
If the RDS 30 has to be triggered externally, the external<br />
trigger signal input is connected to the trigger input (socket 22) and the adequate input circuit<br />
is selected at the control elements 8-12 at the front. With mains-synchronous triggering 7<br />
connection for signal at the trigger input 22 is not required.<br />
All supplied pick-ups (see accessories page 16) can be<br />
connected directly to the "trigger" socket 22. For other<br />
emitters and for external voltage sources the wiring<br />
examples on pages 18-20 should be observed.<br />
Allocation of pins and input wiring can be seen on the<br />
diagram on page 17 and the legend on page 4.<br />
6.3 Monitor socket<br />
Pulse output<br />
The RDS 30 has a pulse output as well as an analog output. The 15V/40mA logic signal of<br />
the pulse output at the monitor socket 23 pin 1/2 is also stepped down at the ratio of the input<br />
divider 12, in accordance with the input pulses. Furthermore, the pulse output is temporarily<br />
short-circuit proof.<br />
Analog output<br />
The analog output is taken from pin 5/2 of socket 23, in form of a frequency proportional<br />
voltage. The voltage is 30 mV/Hz or 500 µV/min -1 and has a linearity of ± 5%.<br />
The analog output is also temporarily short-circuit proof, but has no offset balancing.<br />
External gate input<br />
The hand lamp can also be driven externally via the gate input (monitor socket 23, pin 4/2). In<br />
this case the polarity of the gate (high/low - active) can be selected with the selector switch<br />
"mode 3" 24.<br />