25.03.2013 Views

This Rigger's Handbook is dedicated to Theodore C - Igor Chudov

This Rigger's Handbook is dedicated to Theodore C - Igor Chudov

This Rigger's Handbook is dedicated to Theodore C - Igor Chudov

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

YOUR SLING AND RIGGING SPECIALIST<br />

BLOCK TWISTING<br />

Block tw<strong>is</strong>ting or "cabling" <strong>is</strong> one of the<br />

most frequently encountered wire rope<br />

problems in the construction field. When<br />

th<strong>is</strong> problem occurs, the wire rope <strong>is</strong> most<br />

often blamed, and other equally important<br />

fac<strong>to</strong>rs in the operation are overlooked.<br />

Personnel experienced with handling of<br />

wire rope know that conventional wire<br />

ropes will tw<strong>is</strong>t or unlay slightly, when a<br />

load <strong>is</strong> applied. In a reeved ho<strong>is</strong>ting<br />

system, subjected <strong>to</strong> loading and<br />

unloading such as a load ho<strong>is</strong>ting line, th<strong>is</strong><br />

results in block tw<strong>is</strong>ting and possibly<br />

d<strong>is</strong><strong>to</strong>rtion of the wire rope. Cabling of the<br />

block most frequently occurs as the load<br />

in the wire rope <strong>is</strong> released, and the "falls"<br />

are in a lowered position. Cabling may be<br />

considered as the tw<strong>is</strong>ting of the block<br />

beyond one-half of a revolution (180°<br />

tw<strong>is</strong>ting) of the traveling block. When th<strong>is</strong><br />

condition occurs, the opera<strong>to</strong>r shows good<br />

judgment in not making additional lifts,<br />

until the conditions causing the problem<br />

are corrected.<br />

The following machine and site conditions<br />

should be investigated for possible<br />

improvement in block tw<strong>is</strong>ting.<br />

1. Reduced wire rope length. Longer rope<br />

lengths cause more tw<strong>is</strong>ting than short<br />

rope lengths. <strong>Th<strong>is</strong></strong> applies particularly<br />

<strong>to</strong> the amount of wire rope in the "falls."<br />

2. Reduce the amount of load lifted.<br />

Heavily loaded ropes have more <strong>to</strong>rque<br />

and tw<strong>is</strong>t than lightly loaded ropes.<br />

<strong>Th<strong>is</strong></strong> condition would also apply <strong>to</strong> the<br />

speed of loading or "shock" loading,<br />

since th<strong>is</strong> condition also causes higher<br />

wire rope loading.<br />

3. Eliminate "odd-part" reeving, where the<br />

wire rope "dead-end" <strong>is</strong> on the traveling<br />

block. Wire rope <strong>to</strong>rque, from the<br />

application of load, <strong>is</strong> greatest at the<br />

rope dead-end.<br />

4. Relocate the rope dead-end at the boom,<br />

in order <strong>to</strong> increase the separation<br />

between the dead-end and the other<br />

rope parts. <strong>Th<strong>is</strong></strong> applies a stabilizing<br />

load directly <strong>to</strong> the traveling block. The<br />

original equipment manufacturer should<br />

be consulted before making th<strong>is</strong><br />

modification.<br />

5. Increase sheave size. <strong>Th<strong>is</strong></strong> increases the<br />

amount of separation between wire rope<br />

parts and may improve the situation by<br />

applying stabilizing loads and reducing<br />

the amount of rope <strong>to</strong>rque transmitted <strong>to</strong><br />

the traveling block.<br />

6. Restrain the tw<strong>is</strong>ting block with a "tag"<br />

line. One or more of the foregoing<br />

suggestions may eliminate the problem<br />

without resorting <strong>to</strong> "specialized" wire<br />

rope which may not only be difficult <strong>to</strong><br />

locate but expensive as well.<br />

The use of special "rotation res<strong>is</strong>tant" wire<br />

ropes will not likely be required unless the<br />

intended length of rope "falls" exceeds 100<br />

feet, or the length of the load ho<strong>is</strong>ting line<br />

exceeds 600 feet. In the event these latter<br />

conditions ex<strong>is</strong>t, the user should also<br />

anticipate using a combination of the<br />

"rotation res<strong>is</strong>tant" wire rope and the<br />

foregoing field suggestions for the more<br />

severe problems.<br />

ELASTIC STRETCH<br />

Elastic stretch results from recoverable deformation of the metal itself. Here, again, a<br />

quantity cannot be prec<strong>is</strong>ely calculated. However, the following equation can provide a<br />

reasonable approximation for a good many situations.<br />

Change in load (lb.) x Length (ft.)<br />

Changes in length (ft.) =<br />

Area (in. 2 ) x Modulus of Elasticity (psi)<br />

The modulus of elasticity <strong>is</strong> given below.<br />

APPROXIMATE MODULUS OF ELASTICITY<br />

(POUNDS PER SQUARE INCH)<br />

ROPE ZERO THROUGH 20% 21 TO 65%<br />

CLASSIFICATION LOADING LOADING*<br />

6 x 7 with fiber core 11,700,000 13,000,000<br />

6 x 19 with fiber core 10,800,000 12,000,000<br />

6 x 36 with fiber core 9,900,000 11,000,000<br />

8 x 19 with fiber core 8,100,000 9,000,000<br />

6 x 19 with IWRC 13,500,000 15,000,000<br />

6 x 36 with IWRC 12,600,000 14,000,000<br />

*Applicable <strong>to</strong> new rope, i.e., not previously loaded.<br />

HEADQUARTERS: 55 James E. Casey Drive • Buffalo, NY 14206 PHONE: 716.826.2636 FAX: 716.826.4412 www.hanessupply.com<br />

135<br />

Wire Ropes<br />

PHYSICAL PROPERTIES<br />

ELASTIC PROPERTIES OF WIRE<br />

ROPE<br />

The following d<strong>is</strong>cussion relates <strong>to</strong><br />

conventional 6- or 8-strand ropes that<br />

have either fiber or steel cores; it <strong>is</strong> not<br />

applicable <strong>to</strong> rotation-res<strong>is</strong>tant ropes since<br />

these constitute a separate case.<br />

Wire rope <strong>is</strong> an elastic member; it<br />

stretches or elongates under load. <strong>Th<strong>is</strong></strong><br />

stretch derives from two sources:<br />

1. constructional, and<br />

2. elastic.<br />

In actuality, there may be a third source of<br />

stretch – a result of the rope rotating on its<br />

own ax<strong>is</strong>. Such elongation, which may<br />

occur either as a result of using a swivel,<br />

or from the effect of a free-turning load, <strong>is</strong><br />

brought about by the unlaying of the rope<br />

strands. Because the third source <strong>is</strong> a<br />

subject that <strong>is</strong> beyond the scope of th<strong>is</strong><br />

publication, d<strong>is</strong>cussion will be directed <strong>to</strong><br />

constructional and elastic stretch.<br />

CONSTRUCTIONAL STRETCH<br />

When a load <strong>is</strong> applied <strong>to</strong> wire rope, the<br />

helically-laid wires and strands act in a<br />

constricting manner thereby compressing<br />

the core and bringing all the rope<br />

elements in<strong>to</strong> closer contact. The result <strong>is</strong><br />

a slight reduction in diameter and an<br />

accompanying lengthening of the rope.<br />

Constructional stretch <strong>is</strong> influenced by the<br />

following fac<strong>to</strong>rs:<br />

1. type of core (fiber or steel),<br />

2. rope construction (6 x 7, 6 x 25 FW,<br />

6 x 41 WS, 8 x 19 S, etc.),<br />

3. length of lay<br />

4. material.<br />

Ropes with wire strand core (WSC) or<br />

independent wire rope core (IWRC) have<br />

less constructional stretch than those with<br />

fiber core (FC). The reason for th<strong>is</strong> <strong>is</strong> the<br />

fact that the steel cannot compress as<br />

much as the fiber core.<br />

Usually, constructional stretch will cease<br />

at an early stage in the rope's life.<br />

However, some fiber core ropes, if lightly<br />

loaded (as in the case of eleva<strong>to</strong>r ropes),<br />

may d<strong>is</strong>play a degree of constructional<br />

stretch over a considerable portion of their<br />

life.<br />

A definite value for determining<br />

constructional stretch cannot be assigned<br />

since it <strong>is</strong> influenced by several fac<strong>to</strong>rs.<br />

The following table gives some idea of the<br />

approximate stretch as a percentage of<br />

rope under load.<br />

ROPE CONSTRUCTION APPROX. STRETCH*<br />

6 strand FC 1/2% - 3/4%<br />

6 strand IWRC 1/4% - 1/2%<br />

8 strand FC 3/4% - 1%<br />

*Varies with the magnitude of the loading.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!