Wire Rope<br />

ROTATION RESISTANT<br />

WIRE ROPES<br />

In certain instances the use of rotation res<strong>is</strong>tant<br />

wire rope <strong>is</strong> necessary <strong>to</strong> provide rotational<br />

stability <strong>to</strong> the lifted load. In general, the use of<br />

these specialized wire ropes <strong>is</strong> limited <strong>to</strong> those<br />

situations where it <strong>is</strong> impractical <strong>to</strong>:<br />

1. Use a tag line.<br />

2. Relocate rope dead end.<br />

3. Increase sheave sizes.<br />

4. Eliminate "odd-part" reeving.<br />

5. Significantly reduce rope loading and rope<br />

length.<br />

Rotation res<strong>is</strong>tant wire ropes have less of a<br />

tendency <strong>to</strong> unlay when loaded than do<br />

conventional wire ropes. <strong>Th<strong>is</strong></strong> results in improved<br />

rotational stability <strong>to</strong> the lifted load within a safe<br />

working load range. Rotation res<strong>is</strong>tant wire<br />

ropes are designed in such a way that the<br />

rotational force of the outer rope <strong>is</strong> partially<br />

counteracted by the rotational force of the inner<br />

rope when the rope <strong>is</strong> subjected <strong>to</strong> a load.<br />

The rated strengths of rotation res<strong>is</strong>tant ropes<br />

are less than the conventional 6 x 19 and 6 x 36<br />

Classification wire ropes, and larger sheaves<br />

and drums are required in order <strong>to</strong> achieve<br />

comparable fatigue life. Drum and sheave<br />

diameters should be 34 <strong>to</strong> 36 times rope<br />

diameter for the 19 x 7 and 35 x 7 rotation<br />

res<strong>is</strong>tant ropes and 21 <strong>to</strong> 27 times rope diameter<br />

for 8 x 19 rotation res<strong>is</strong>tant ropes.<br />

Rotation Res<strong>is</strong>tant Ropes are available in a full<br />

range of sizes, grades and constructions:<br />

• Standard constructions for single-part and<br />

multi-part lifting.<br />

• Special wire rope constructions for increased<br />

service life in particularly demanding<br />

applications – Dyform ®-18 HSLR, Dyform ®<br />

34LR and 35LS.<br />

NOTE:<br />

1.Swivels are not recommended for use with<br />

rotation res<strong>is</strong>tant ropes.<br />

2.Although B30 standards permit rotation<br />

res<strong>is</strong>tant ropes <strong>to</strong> be used under certain<br />

conditions at design fac<strong>to</strong>rs of 3.5:1, we<br />

recommend a minimum design fac<strong>to</strong>r of 5:1<br />

and a design fac<strong>to</strong>r of 7:1 for extended rope<br />

life.<br />

Dyform ® - 18HSLR<br />

Rotation Res<strong>is</strong>tant<br />

For multi-part lifting.<br />

35% greater strength.<br />

DYFORM ®-18 HSLR<br />

ROTATION RESISTANT ROPE<br />

NOMINAL APPROX.<br />

DIA. STRENGTH* WT/FT<br />

(IN.)† (TONS) (LBS)<br />

3/8 8.3 .27<br />

7/16 11.2 .37<br />

1/2 14.6 .51<br />

9/16 18.5 .64<br />

5/8 22.7 .79<br />

3/4 32.4 1.1<br />

7/8 43.8 1.5<br />

1 57.5 2.0<br />

1-1/8 71.5 2.5<br />

1-1/4 87.9 3.1<br />

Dyform ® - 34LR<br />

Strongest, most rotation<br />

res<strong>is</strong>tant. For the most<br />

demanding ho<strong>is</strong>ting<br />

applications.<br />

35LS<br />

For demanding<br />

applications where<br />

highest strength <strong>is</strong> not<br />

manda<strong>to</strong>ry.<br />

19 x 7<br />

Rotation Res<strong>is</strong>tant<br />

Not recommended for<br />

multiple part lifting.<br />

8 x 19<br />

Rotation Res<strong>is</strong>tant<br />

Can be used for multiple<br />

part lifting.<br />

HEADQUARTERS: 55 James E. Casey Drive • Buffalo, NY 14206 PHONE: 716.826.2636 FAX: 716.826.4412 www.hanessupply.com<br />

122<br />

YOUR SLING AND RIGGING SPECIALIST<br />

DYFORM ®-34LR & 35LS ROTATION RESISTANCE ROPE<br />

MIN. BREAKING FORCE** APPROX.<br />

(TONS) WT/FT (LBS)<br />

DIAMETER 1960 2160<br />

(MM) (IN.) 34LR 35LS 34LR 34LR 35LS<br />

– 1/2 15.40 13.60 17.42 .54 .49<br />

13 – 16.19 14.28 18.21 .57 .51<br />

14 – 18.88 16.52 21.13 .65 .60<br />

– 9/16 19.67 17.31 22.03 .69 .62<br />

15 – 22.03 19.11 24.73 .77 .69<br />

16 5/8 25.18 21.69 28.21 .87 .78<br />

17 – 27.20 24.28 30.46 .94 .87<br />

18 – 30.80 27.09 34.62 1.07 ..97<br />

19 3/4 34.51 30.91 38.67 1.20 1.11<br />

20 – 38.33 33.61 42.94 1.32 1.21<br />

21 – 43.28 37.43 48.45 1.49 1.34<br />

22 – 46.65 41.37 52.38 1.61 1.49<br />

– 7/8 47.21 41.59 53.06 1.65 1.51<br />

23 – 50.69 44.74 56.88 1.75 1.61<br />

24 – 55.64 49.35 62.38 1.92 1.77<br />

25 – 60.59 52.94 67.89 2.10 1.91<br />

– 1 62.38 54.40 70.03 2.16 1.97<br />

26 – 66.09 57.78 74.19 2.28 2.08<br />

28 – 75.99 66.99 85.20 2.63 2.41<br />

– 1-1/8 77.45 68.90 86.89 2.70 2.50<br />

30 – 86.44 75.99 97.01 2.99 2.74<br />

32 1-1/4 98.13 85.99 110.16 3.39 3.10<br />

35 1-3/8 116.90 105.89 123.65 4.05 3.82<br />

38 1-1/2 138.26 120.27 147.25 4.87 4.35<br />

19 X 7 ROTATION RESISTANT ROPE<br />

NOMINAL STRENGTH* APPROX.<br />

DIA. (TONS) WT/FT<br />

(IN.) EIP IPS (LBS)<br />

3/16 1.57 1.42 .064<br />

1/4 2.77 2.51 .113<br />

5/16 4.30 3.90 .177<br />

3/8 6.15 5.59 .25<br />

7/16 8.33 7.58 .35<br />

1/2 10.8 9.85 .45<br />

9/16 13.6 12.4 .58<br />

5/8 16.8 15.3 .71<br />

3/4 24.0 21.8 1.02<br />

7/8 32.5 29.5 1.39<br />

1 42.2 38.3 1.82<br />

1-1/8 53.1 48.2 2.30<br />

1-1/4 65.1 59.2 2.80<br />

1-3/8 78.4 71.3 3.43<br />

1-1/2 92.8 84.4 4.08<br />

1-5/8 108.0 98.4 4.80<br />

8 X 19 ROTATION RESISTANT ROPE<br />

7/16 8.97 7.80 .36<br />

1/2 11.7 10.2 .47<br />

9/16 14.7 12.8 .60<br />

5/8 18.1 15.7 .73<br />

3/4 25.9 22.6 1.06<br />

7/8 35.0 30.5 1.44<br />

1 45.5 39.6 1.88<br />

1-1/8 57.3 49.8 2.39<br />

1-1/4 70.5 61.3 2.94<br />

1-3/8 84.9 73.8 3.56<br />

1-1/2 100.0 87.3 4.24<br />

*Acceptance strength <strong>is</strong> not less than 2-1/2% below the nominal<br />

breaking strengths l<strong>is</strong>ted.<br />

NOTE: These strengths apply only when a test <strong>is</strong> conducted<br />

with both ends fixed. When in use, the strength of<br />

these ropes may be reduced if one end <strong>is</strong> free <strong>to</strong> rotate.<br />

**L<strong>is</strong>ted minimum breaking force <strong>is</strong> for 1960 & 2160 grade<br />

bright (ungalvanized) ropes. Inquire for a minimum breaking<br />

force of glavanized ropes.<br />