7/8<br />
In CIS modules (WSG0036E075 of Würth and SCG55-HV-F of Sulfurcell) the initial power Pa as<br />
measured out of the box is always lower than the initial limits of allowance of the modules. The low<br />
intensity of the indoor applied bias light is probably not sufficient to stabilise the power to its real value.<br />
It is expected that the first exposure at outdoor conditions will bring the power closer to declared power.<br />
Remarks regarding the measurement of some module types:<br />
� Electrical characterization of Sanyo HIP-210 NKHE1 modules, with HIT solar cells, is made by<br />
means of multiflash method due to the presence of capacitance effects;<br />
� Measurements on amorphous silicon devices (Sharp NA-851WQ and Bangkok Solar BS40) are<br />
performed with filtered reference cell (nominal power Pn refers to stabilized power);<br />
� Measurement on CIS samples (Würth WSG0036E075 and Sulfurcell SCG55-HV-F) are performed<br />
with bias light.<br />
The measurements have been effectuated with the reference cell calibrated according to the updated<br />
norm IEC 60904-3 (version 2008). In the new norm has been defined a standard spectrum slightly<br />
different. This change leads to a difference in power of +0.69%. The Pn values supplied by the manufactures<br />
are presumably defined in function of the previous version of the norm (1989).<br />
Long term outdoor Energy rating measurements<br />
In 2008 the request of services for outdoor measurements for the energy rating comparison has<br />
grown. Unfortunately, in 2008, only 3 (three) Energy Rating comparison in field were performed for the<br />
industry. Indeed the roof of the SUPSI building where it was planned to accommodate the installations,<br />
propriety of the Canton of Ticino, has not been yet restored. Moreover the supplemental stands<br />
used so far, have been employed for another research project [5] and it was not possible to use them<br />
for the services.<br />
The construction of the stands (MPPT3000 and box) has continued. To be totally operative by the end<br />
of March <strong>2009</strong>, the old plant of 10 kWp will be dismantled (building B) in order to leave room for the<br />
new stands, and afterwards it will be reinstated on the new restored roof (building A).<br />
For the construction of the new MPPT3000 [2] it has been decided to look to the outsourcing. All the<br />
electronic assembly was outsourced to Juri Elettronica as main supplier. In order to outsource the<br />
product it was necessary to prepare a planning of the project, create new bills of materials (BOM) and<br />
working process procedures. Juri Electronica has ordered all the materials and components to assembly<br />
the three pcb's (Power Print, ADSP print and Display print) and then they have mounted traditional<br />
and SMD components. The assembly of heat sink and pcbs and the rest of materials was made<br />
by ISAAC staff (assembly of the Power print on the heat sink, fix diodes and transistors. Assembly the<br />
ADSP print using spacers and connectors. Connect and fix the display print. Build and sold the coil,<br />
sold the capacitors and connectors on the pcb.<br />
Once the assembly of the MPPT is done, electronic examinations and calibration tests are necessary.<br />
60pcs of MPPT3000 have been produced for this project use and for various other projects (Scerri,<br />
Bellinzona / CPT 2, Canobbio). The rest 40pcs are available for future projects and also for sale.<br />
National and International collaborations<br />
Solarday (I); Ocean Optics, (UK), GMP, (CH); ECN, (NL) ; TÜV, Köln (D) ; JRC, Ispra (I) ; PASAN SA,<br />
P.-R. Beljean, Neuchâtel (CH) ; EU FP6 IP « PERFORMANCE » project [2] partner ; Dipartimento<br />
Tecnologie Innovative (DTI), SUPSI ; Juri Electronica, Ambrì (CH), PSI, Villigen (CH).<br />
Centrale di test ISAAC-TISO, D. Chianese, SUPSI, DACD, ISAAC-TISO<br />
207/290