Département fédéral de l’environnement,<br />

des transports, de l’énergie et de la communication DETEC<br />

Office fédéral de l’énergie OFEN<br />

CENTRALE DI TEST ISAAC-TISO<br />

QUALITÀ E RESA ENERGETICA DI MODULI<br />

FOTOVOLTAICI<br />

Annual Report 2008<br />

Author and Co-Authors D. Chianese, N. Cereghetti, A. Realini, G. Friesen, E. Burà,<br />

I. Pola, T. Friesen, Roman Rudel<br />

Institution / Company Scuola Universitaria Professionale della Svizzera Italiana SUPSI,<br />

DACD, Istituto di Sostenibilità Applicata all’Ambiente Costruito<br />

ISAAC-TISO<br />

Address Via Trevano, CH – 6952 Canobbio<br />

Telephone, E-mail, Homepage +41 (0) 58 666 63 56; domenico.chianese@supsi.ch;<br />

www.isaac.supsi.ch<br />

Project- / Contract Number 36508 / 153027<br />

Duration of the Project (from – to) 01.11.2007 - 31.12.2010<br />

Date December 2008<br />

ABSTRACT<br />

During 2008 more than 6140 flashes were performed for research programmes (test centre and other<br />

projects), I-V measurements for third-parties and maintenance measurements (accreditation maintenance).<br />

A total of 458 I-V measurement, 18 determination of the temperature coefficients, 15 I-V<br />

characterization at different irradiances (200, 400, 600 and 800 W/m²), 11 outdoor initial degradation<br />

(30-60 kWh/m²) and 72 I-V determination with multiflash method were performed for third-parties.<br />

In October 2008 the eighth quality audit, for the ISO17025 accreditation maintenance, supervised by<br />

the Swiss Accreditation Service, was successfully passed. The accreditation of the I-V measurements<br />

at different irradiances has been postponed in order to conform the laboratory to the new version<br />

(2008) of the IEC 60904-3 standard. In particular, a new procedure for the irradiance uniformity verification<br />

with two special reference modules and electronics have been designed.<br />

The spectrale response (SR) measurement with automate filter positioning and data acquisition will<br />

be implemented with the new Pasan IIIB sun simulator. A solution, in collaboration with two industrial<br />

partner, consisting in a composition of two CCD spectroradiometers sensitive in ranges 200-1100nm<br />

and 900-1700nm respectively, was selected for the monitoring of the flash spectrum of the sun simulator<br />

In 2008 a new 15 months test cycle (no.11) began. Thirteen different module types were chosen, in<br />

an attempt to include the greater part of available technologies: 4 mc-Si (one with EWT backcontact),<br />

4 sc-Si, 1 HIT (new version), 1 a-Si/a-Si tandem module, 1 a-Si/µc-Si (micromorph) and 2 CIS.<br />

In test cycle 11 the power at the purchase of crystalline silicon technologies (including HIT) was on<br />

average -2.6% lower with respect to Pn but ranging from +0.5% to -10.5%. In 8 of 27 cases power at<br />

purchase was outside production tolerance.<br />

In order to built the test stand for outdoor measurements comparison of the ER for industry, 60pcs of<br />

the new MPPT3000 have been produced.<br />