9/9<br />

� 4 energy rating comparison were performed for third-parties.<br />

� In test cycle 10 the power at the purchase of c-Si module was on average 1.5% lower with respect<br />

to Pn but ranging from 0.2% and -3.8%.<br />

� Stabilized power of c-Si module after 15 months is on average 3.7% lower with respect to Pn and<br />

ranging from -0.7% and -8.2%. All type of modules are in the warranty limits.<br />

� Despite during the last few years the accuracy of power declarations has improved constantly,<br />

warranty limits are sometimes unclear.<br />

� Initial power degradation {(P0-Pa)/Pa} of c-Si modules is on average – 1.1%, ranging from +0.6%<br />

to -2.9%.<br />

� In the standard modules with c-Si cells, the average reduction after one year of exposure (from<br />

P3 to P15) in almost cases were very low, ranging from -0.5% and -2.0%.<br />

� Differences in annual energy production [kWh/kWp], of 14 different module types, with nominal<br />

power Pn as reference, reach 10%.<br />

� For Lugano, the indoor measured power matrix is able to explain a large part of the differences in<br />

kWh observed under real operating conditions.<br />

� High resolution data of a single day (1 minute intervals) are sufficient to determine the power matrix<br />

of a module when fitting the raw data to the equations 1 and 2 of the matrix method [2].<br />

� The new homepage www.bipv.ch was completed with new BIPV product examples.<br />

5 References<br />

[1] D. Chianese et. al.: Direct Performance Comparison of PV Modules, 22 nd EPVSEC, Milan (I), 2007.<br />

[2] G. Friesen et al.: Energy Rating Measurements and Predictions at ISAAC-TISO, 22 nd EPVSEC, Milan (I), 2007.<br />

[3] Kim Nagel, Physical properties of PV modules used as glasses in the building sector, Solar Glass Conference 2007,<br />

Milano (I), November 2007.<br />

[4] Chianese D., Nagel K., Pola I., BiPV Projekte, 4. Workshop “<strong>Photovoltaik</strong>-Modultechnik”, November 2007, Köln (D).<br />

[5] D. Chianese, K. Nagel, “WWW.BIPV.CH”, 9. Symposium Photovoltaïque National, Emmenbrücke, Novembre 2007.<br />

[6] www.isaac.supsi.ch ; www.bipv.ch<br />

Centrale di test ISAAC-TISO, D. Chianese, ISAAC-TISO Seite 167 von 288