3/9<br />

Service measurements<br />

In 2007 a total of 342 I-V measurement were performed for third-parties. For several modules, in addition<br />

to the I-V determination, other measurements were executed:<br />

� 22 determination of the temperature coefficients;<br />

� 21 I-V characterization at different irradiances (200, 400, 600 and 800 W/m²);<br />

� 47 outdoor initial degradation (20-40 kWh/m²), were the IV characterization is performed before<br />

and after the exposure;<br />

� I-V determination with multiflash method;<br />

� Visual inspection (according to IEC 61215);<br />

� Insulation test (according to IEC 61215);<br />

� Electrical continuity test;<br />

� By-pass diode test.<br />

N° of modules<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

73<br />

TERZI Sussidi TI Progetto PVE International Intercomparison Progetto PV Performance<br />

104<br />

190<br />

12<br />

95<br />

30<br />

97<br />

10<br />

163 158 156<br />

2001 2002 2003 2004 2005 2006 2007<br />

Year<br />

12<br />

41<br />

262<br />

342<br />

Figure 1: evolution of<br />

service measurements<br />

at ISAAC-TISO<br />

From 2001 to 2007 the<br />

total amount of services<br />

measurements with the<br />

sun simulator was 249<br />

meas./year.<br />

3.2 Outdoor Test (cycle no. 10)<br />

3.2.1 Power verification<br />

In March 2006 a new 15 months test cycle (no.10) began and ended in June 2007 [1]. Fourteen different<br />

module types were chosen, in an attempt to include the greater part of available technologies: 8<br />

mc-Si, 2 sc-Si, 1 HIT, 2 a-Si and 1 CdTe. Power (Pn), production tolerance (tp) and warranties (w)<br />

given by the manufacturer are shown in Table 1.<br />

Type of<br />

meas.<br />

Direct with c-<br />

Si ref cell<br />

Multiflash<br />

Direct with<br />

filtered c-Si<br />

ref cell<br />

MODULE<br />

Cell Type Pn [W]<br />

tp<br />

(tolerance)<br />

[%] / [%]<br />

Pa [W]<br />

(Pa-Pn)/Pn<br />

(%)<br />

w<br />

(warranty)<br />

[%] (years)<br />

P15 [W]<br />

(P15-Pn)/Pn<br />

(%)<br />

Miitsubishi PV-MF130EA2LF mc-Si 130 + 10 / - 5% 130.2 0.1% NA 129.1 -0.7%<br />

Suntech STP150-24 mc-Si 150 � 3% 150.1 0.1% 90 (12y) 147.7 -1.5%<br />

Kyocera KC125GHT-2 mc-Si 125 + 10 / - 5% 123.7 -1.0% 90 (12y) 121.1 -3.1%<br />

RWE ASE-165-GT-FT mc-Si 165 � 4% 161.6 -2.0% NA 154.9 -6.1%<br />

Solarwatt MHHplus220 mc-Si 210 � 3% 202.0 -3.8% 90 (12y) 192.8 -8.2%<br />

IBC-215S Megaline mc-Si 215 � 2.5% 210.3 -2.2% 90 (12y) 209.8 -2.4%<br />

Solar World SW165 mc-Si 165 � 3% 162.9 -1.3% 90 (10y) 159.4 -3.4%<br />

BP Solar BP7180 sc-Si 180 - 0 / + 2.5% 174.7 -2.9% 90 (12y) 170.2 -5.5%<br />

Sharp NT-175E1 sc-Si 175 � 5% 174.0 -0.6% NA 171.2 -2.2%<br />

Sanyo HIP180NE1 HIT 180 + 10 / - 5% 180.4 0.2% 80 (20y) 176.3 -2.0%<br />

Sunpower STM210 F sc-Si 210 - 0 / + 3% 204.6 -2.6% 80 (25y) 199.8 -4.8%<br />

First Solar FS-60 CdTe 60 � 5% NaN NaN 90 (10y) 57.9 -3.5%<br />

Kaneka K60 a-Si 60 + 10 / - 5% 84.0 39.9% 90 (12y) 55.8 -7.0%<br />

UniSolar ES-62T a-Si 62 � 5% 64.3 3.6% (10y) 54.4 -12.3%<br />

Table 1: Warranties and differences between initial power (Pa), stabilised power (P15) vs. nominal<br />

power (Pn), sorted by type of measurement (i.e. direct, multiflash or direct with spectral<br />

matched reference cell) and cell typology.<br />

Centrale di test ISAAC-TISO, D. Chianese, ISAAC-TISO Seite 161 von 288