29.09.2012 Views

Programm Photovoltaik Ausgabe 2008 ... - Bundesamt für Energie BFE

Programm Photovoltaik Ausgabe 2008 ... - Bundesamt für Energie BFE

Programm Photovoltaik Ausgabe 2008 ... - Bundesamt für Energie BFE

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Département fédéral de l’environnement,<br />

des transports, de l’énergie et de la communication DETEC<br />

Office fédéral de l’énergie OFEN<br />

CENTRALE DI TEST ISAAC-TISO<br />

QUALITÀ E RESA ENERGETICA DI MODULI<br />

FOTOVOLTAICI<br />

Annual Report 2007<br />

Author and Co-Authors D. Chianese, A. Bernasconi, N. Cereghetti, A. Realini, G. Friesen,<br />

E. Burà, I. Pola, K. Nagel<br />

Institution / Company Scuola Universitaria Professionale della Svizzera Italiana SUPSI,<br />

DACD, Istituto di Sostenibilità Applicata all’Ambiente Costruito<br />

ISAAC-TISO<br />

Address Via Trevano, CH – 6952 Canobbio<br />

Telephone, E-mail, Homepage +41 (0) 58 666 63 56; domenico.chianese@supsi.ch;<br />

www.isaac.supsi.ch<br />

Project- / Contract Number 36508 / 151135<br />

Duration of the Project (from – to) from October 2003 to December 2006<br />

Date December 2007<br />

ABSTRACT<br />

The aim of the “ISAAC-TISO Test Centre” is to control the quality and reliability of photovoltaic modules<br />

and to promote the use of BIPV products. The main activities are: indoor measurements carried<br />

out with a class A flash sun simulator, outdoor analysis of the behaviour of PV modules under environmental<br />

conditions and study of the main obstacles encountered by architects within the relatively<br />

new photovoltaic building integration (BiPV) sector.<br />

In April 2007 the seventh quality audit, for the ISO17025 accreditation maintenance of the sun simulator,<br />

supervised by the Swiss Accreditation Service, was successfully passed.<br />

During 2007 services for third-parties have increased significantly. A total of 342 indoor I-V measurement<br />

were performed. In addition for several modules other measurements were executed: 22 determination<br />

of the temperature coefficients; 21 I-V characterization at different irradiances (200, 400, 600<br />

and 800 W/m²); 47 outdoor initial degradation (20-40 kWh/m²); I-V determination with multiflash<br />

method; Visual inspection and insulation test according to IEC 61215; Electrical continuity test; Bypass<br />

diode test. Moreover 4 energy rating comparison were performed.<br />

In March 2006 a new 15 months test cycle (no.10) began and ended in June 2007. Stabilized power<br />

of c-Si module after 15 months is on average 3.7% lower with respect to Pn and ranging from -0.7%<br />

and -8.2% and thus all type of modules are in the warranty limits. Differences in annual energy production<br />

[kWh/kWp], of 14 different module types, with nominal power Pn as reference, reach 10% but<br />

are lower with respect to measured real power.<br />

During 2007 collaborations with 6 institutes (either Universities and manufactures) have been<br />

achieved for the installation of systems equipped with MPPT3K testing devices which were developed<br />

by ISAAC-TISO.<br />

The new information homepage on BIPV was completed with a database of BIPV product, BIPV<br />

fastening and system example (see www.bipv.ch).<br />

Seite 159 von 288