25.03.2013 Views

Prime User Manual - ISP

Prime User Manual - ISP

Prime User Manual - ISP

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Chapter 9: Docking Covalently Bound Ligands<br />

When you are satisfied with the SMARTS pattern, you must then designate an atom on the<br />

ligand that is removed, along with the atoms attached to it, when the ligand forms a bond with<br />

the receptor. The fragment with the smaller number of atoms is the part that is removed. The<br />

atom is specified by its index (position) in the SMARTS pattern; the first atom index is 1. This<br />

index must be entered into the Leaving atom text box.<br />

Having defined a SMARTS pattern and the leaving group, click Add. The SMARTS pattern is<br />

added to the table below, and will be used when processing the ligands. You can repeat this<br />

process for as many SMARTS patterns as you want to use. If you want to remove a pattern<br />

from the table, select it and click Remove.<br />

9.1.3 Specifying the Receptor Bond to Break<br />

In the Receptor options section you specify the bond in the receptor that is broken to form a<br />

bond with the ligand. The receptor must be displayed in the Workspace, and is written to a file<br />

when you start the job.<br />

To define the bond that is broken, select Pick receptor bond to break, and pick the desired bond<br />

on the receptor in the Workspace. The Staying atom and Leaving atom text boxes are filled with<br />

the atom numbers of the atom in the bond that remains and the atom in the bond that is<br />

removed when the bond is broken. The bond is marked in the Workspace with yellow markers.<br />

If you pick the wrong bond, you can simply pick again, and the new bond replaces the old.<br />

You can also enter or edit the atom numbers in the Staying atom and Leaving atom text boxes.<br />

To ensure that you have the correct atom numbers, you should label the atoms. For more information<br />

on labeling atoms, see Section 6.3 of the Maestro <strong>User</strong> <strong>Manual</strong>.<br />

9.1.4 Specifying Receptor Residues to Sample<br />

In the Receptor options section you can also choose residues that are allowed to adjust to the<br />

formation of the covalent complex in the loop sampling procedure.<br />

The first choice is whether to sample the residue that is attached to the ligand. To do so, select<br />

Sample attachment residue.<br />

The next step is to pick other residues in the Workspace for sampling. To do so, select Pick<br />

additional residue to sample, and pick residues in the Workspace. You can pick any number of<br />

residues. As well as picking, you can select the desired residues in the Atom Selection dialog<br />

box, which you open by clicking Select. The residues that you select by either method are<br />

listed in the Additional residues text box.<br />

<strong>Prime</strong> 2.1 <strong>User</strong> <strong>Manual</strong> 79

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!