25.03.2013 Views

Prime User Manual - ISP

Prime User Manual - ISP

Prime User Manual - ISP

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Chapter 7: <strong>Prime</strong>–Refinement<br />

The text below the option and menu displays the recommended loop length for the selected<br />

accuracy.<br />

Extended sampling samples loop conformations more thoroughly, using a series of loop<br />

constraint settings. Up to eight processors can be used simultaneously to perform loop refinement.<br />

Extended sampling can be run at four different sampling levels: Low, Medium, High, and<br />

Ultra. If you select Ultra Extended, you can only refine one loop at a time.<br />

Job<br />

These options allow you to set a limit on the number of processors over which to distribute the<br />

loop sampling subjobs. Each sampling method runs in several stages, and each stage can use a<br />

different number of processors. The maximum number of processors that can be used by the<br />

different sampling methods are:<br />

Default 1<br />

Extended Low 2<br />

Extended Medium 4<br />

Extended High 8<br />

Ultra Extended 8*L (L is the loop length)<br />

• To make use of as many processors as are available, select Distribute subjobs over maximum<br />

available processors.<br />

• To set the maximum number of processors, select Distribute subjobs over and enter a<br />

value in the text box.<br />

Output for single loop feature<br />

These options determine how many structures are returned:<br />

• Maximum number of structures to return: Select this option to return more than one structure<br />

for each loop specified for refinement. The default when this option is selected is to<br />

return 4 structures for each loop.<br />

• Energy cutoff: Select this option to prevent higher-energy structures from being returned.<br />

Structures whose energy is higher than that of the lowest-energy structure by more than<br />

this amount are not returned. The default cutoff when this option is selected is 10 kcal/<br />

mol.<br />

The following settings are applied to the loops you have selected for refinement.<br />

• Maximum CA movement: To limit the extent to which alpha carbon atoms can move from<br />

their original positions, select this option, and enter a limit in the text box. The default<br />

distance is 3.0 Å. The extended sampling procedure tests multiple values for Maximum<br />

CA movement, so this option is unavailable when extended sampling is selected.<br />

<strong>Prime</strong> 2.1 <strong>User</strong> <strong>Manual</strong> 65

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!