22.03.2013 Views

Sure-Grip® Power Chuck

Sure-Grip® Power Chuck

Sure-Grip® Power Chuck

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Sure</strong>-Grip ® <strong>Power</strong> <strong>Chuck</strong> Safety and Technical Manual B-87Z<br />

The <strong>Chuck</strong>ing Ratio = d Z ÷ d SP can be determined from your specific working conditions or obtained from the chart<br />

below.<br />

<strong>Chuck</strong>ing Ratio (d Z ÷ d SP) – Table 4<br />

<strong>Chuck</strong>ing Machining Diameter (Dz) mm/inch<br />

Diameter<br />

mm/inch 20 40 60 80 100 150 200 250 300 350 400 500<br />

(Dsp) .787" 1.574" 2.362" 3.149" 3.937" 5.905" 7.875" 9.843 11.811" 13.779 15.748" 19.985"<br />

20mm 1 2 3 4 - - - - - - - -<br />

0.787"<br />

40mm 0.5 1 1.5 2.0 2.5 3.8 - - - - - -<br />

1.574"<br />

60mm 0.33 0.67 1 1.3 1.7 2.5 3.3 4.2 - - - -<br />

2.362"<br />

80mm 0.25 0.5 0.75 1.0 1.3 1.9 2.5 3.1 3.8 4.4 - -<br />

3.149"<br />

100mm 0.2 0.4 0.6 0.8 1.0 1.5 2. 2.5 3.0 3.5 4.0<br />

3.937"<br />

150mm 0.13 0.27 0.4 0.53 0.67 1.0 1.3 1.7 2.0 2.3 2.7 3.3<br />

5.905"<br />

200mm - 0.2 0.3 0.4 0.5 0.75 1.0 1.3 1.5 1.8 2.0 2.5<br />

7.875"<br />

250mm - 0.16 0.25 0.32 0.4 0.6 0.8 1.0 1.2 1.4 1.6 2.0<br />

9.843"<br />

300mm - - 0.2 0.27 0.33 0.5 0.67 0.83 1.0 1.2 1.3 1.7<br />

11.811"<br />

350mm - - 0.17 0.23 0.29 0.43 0.57 0.72 0.88 1.0 1.1 1.4<br />

13.779"<br />

400mm - - - 0.2 0.25 0.38 0.5 0.62 0.75 0.87 1.0 1.3<br />

15.748"<br />

500mm - - - 0.16 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1.0<br />

19.985"<br />

Hardinge Inc. One Hardinge Drive, Elmira, New York U.S.A. 14902-1507 800.843.8801 www.hardingetooling.com<br />

109

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!