6700 Portable Sampler User Manual - Isco
6700 Portable Sampler User Manual - Isco
6700 Portable Sampler User Manual - Isco
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>6700</strong> SAMPLERS<br />
Table 3: Technical Specifications for the <strong>6700</strong> Compact and Standard <strong>Sampler</strong>s<br />
<strong>6700</strong> STANDARD PORTABLE SAMPLER: PHYSICAL SPECIFICATIONS (CONTINUED)<br />
Cooling Capacity:<br />
Configuration:<br />
24 plastic bottles<br />
24 glass bottles<br />
12 plastic bottles<br />
12 glass bottles<br />
8 plastic bottles<br />
8 glass bottles<br />
4 plastic bottles<br />
4 glass bottles<br />
1 plastic bottle<br />
1 glass bottle<br />
Sample Size Cooling Water Last Sample Last Sample Temp<br />
500 ml Sample 61°F (16°C) Sample 24 63°F (17°C)<br />
175 ml Sample 39°F (4°C) Sample 24 41°F (5°C)<br />
500 ml Sample 36°F (2°C) Sample 12 54°F (12°C)<br />
475 ml Sample 36°F (2°C) Sample 12 54°F (12°C)<br />
1,000 ml Sample 50°F (10°C) Sample 8 57°F (14°C)<br />
900 ml Sample 37°F (3°C) Sample 8 54°F (12°C)<br />
1,850 ml Sample 34°F (1°C) Sample 4 34°F (1°C)<br />
1,850 ml Sample 37°F (3°C) Sample 4 37°F (3°C)<br />
12–400 ml Samples 37°F (3°C) Composite Sample 37°F (3°C)<br />
12–400 ml Samples 36°F (2°C) Composite Sample 36°F (2°C)<br />
Thecoolingcapacityisthetemperatureofthesampleandthecoolingwater24hoursafterthelastsampleis<br />
taken. The amount of ice specified for the ice capacity was used. The temperature of the sample liquid is 65°F<br />
(18°C). The ambient temperature is 75°F (24°C).<br />
Average Thermal<br />
Resistance Factor:<br />
R-10<br />
The average R-value for a complete sampler. This includes a tub, center section, top cover, controller, pump tube,<br />
distributor arm, and discharge tube.<br />
<strong>6700</strong> STANDARD SAMPLER WITH OPTIONAL 5GALLON BOTTLE BASE: PHYSICAL SPECIFICATIONS<br />
Dimensions<br />
Base Alone:<br />
Assembled <strong>Sampler</strong>:<br />
Height: 15.4 inches (39.1 cm) Diameter: 19.9 inches (50.6 cm)<br />
Height: 31.5 inches (80.0 cm) Diameter: 19.9 inches (50.6 cm)<br />
<strong>Sampler</strong> Tub Configuration: 1 round glass bottle, 5 gallons (18.9 liters)<br />
Dry Weight: 52 lbs (24 kg)<br />
This includes the top cover, center section, bottle base, 5 gallon glass bottle, controller, pump tube, and discharge<br />
tube.<br />
Ice Capacity: 21 lbs (9.5 kg)<br />
3 /4" × 3 /4" × 1 /4" approximate ice cube size. Ice capacity will vary with the size of the cubes.<br />
Filled Bottle Weight: 115 lbs (52 kg)<br />
This includes everything in the Dry Weight and the Ice Capacity specifications, and the bottle is filled to the<br />
capacities listed in <strong>Sampler</strong> Tub Configurations. This weight does not include a power source.<br />
Cooling Capacity: Sample Size Cooling Water Composite Sample Temperature<br />
12–800 ml Samples 36°F (2°C) 36°F (2°C)<br />
Thecoolingcapacityisthetemperatureofthesampleandthecoolingwater24hoursafterthelastsampleis<br />
taken. The amount of ice used is specified in “ice capacity.” The sampler is set up to take one sample every hour<br />
for twelve hours filling the bottle half full. The temperature of the incoming sample liquid is 65°F (18°C). The<br />
ambient temperature is 75°F (24°C).<br />
Average Thermal<br />
Resistance Factor:<br />
R-10<br />
This is the average R-value for the complete sampler. This includes a bottle base, center section, top cover,<br />
controller, pump tube, discharge tube, and composite tube guide.<br />
12