22.03.2013 Views

6700 Portable Sampler User Manual - Isco

6700 Portable Sampler User Manual - Isco

6700 Portable Sampler User Manual - Isco

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>6700</strong> SAMPLERS<br />

Figure 47 Analog Output and Dialout Screens<br />

See Figure 43, Extended<br />

Programming: Hardware Screens.<br />

If applicable<br />

See Note A<br />

ANALOG OUTPUT<br />

HARDWARE HAS NOT<br />

BEEN INSTALLED!<br />

PERIODIC<br />

SERIAL OUTPUT?<br />

YES NO<br />

Yes<br />

If applicable<br />

See Note B<br />

I/Ox=1,2<br />

DIALOUT WHEN I/Ox<br />

BECOMES TRUE?<br />

YES NO<br />

I/Ox=3<br />

1.<br />

2.<br />

3.<br />

SETUP<br />

MANUAL CONTROL<br />

PORT SETTINGS<br />

9600N81 4800N81<br />

2400N81 1200N81<br />

DIALOUT NUMBERS:<br />

__ MINUTE<br />

DELAY BETWEEN CALLS<br />

(0-99)<br />

A. Factory installed option. Requires B1 hardware or newer.<br />

B. Requires factory-installed Dialout Modem and B2 hardware or newer.<br />

Figure 48 Analog Output and Dialout Quick View Screens<br />

See Figure 44, Extended Programming:<br />

Hardware Quick View Screens.<br />

If applicable<br />

See Note<br />

ANALOG OUTPUT<br />

HARDWARE HAS NOT<br />

BEEN INSTALLED!<br />

_ ANALOG OUTPUTS<br />

SERIAL OUTPUT<br />

EVERY __ MINUTES<br />

DIALOUT EACH TIME<br />

I/Ox<br />

BECOMES TRUE<br />

SETUP<br />

MANUAL CONTROL<br />

PERIODIC<br />

SERIAL OUTPUT?<br />

YES NO<br />

If applicable<br />

See Note B<br />

DIALOUT WHEN I/Ox<br />

BECOMES TRUE?<br />

YES NO<br />

I/Ox=1,2<br />

133<br />

Notes<br />

SET ANALOG OUTPUT _<br />

TO __.__ mA<br />

DONE<br />

Yes<br />

I/Ox<br />

=3<br />

SERIAL OUTPUT EVERY:<br />

15 SEC 1 MIN<br />

5 MIN 15 MIN<br />

When DECIMAL POINT key is pressed<br />

SELECT CODE:<br />

, # *<br />

SET ANALOG OUTPUT _<br />

TO __.__ mA<br />

DONE<br />

PORT SETTINGS<br />

9600N81 4800N81<br />

2400N81 1200N81<br />

Notes<br />

ANALOG OUPUT _:<br />

LEVEL VELOCITY<br />

FLOW NONE<br />

ANALOG OUTPUT _:<br />

0-TO-20 mA<br />

4-TO-20 mA<br />

ANALOG OUTPUT _:<br />

0 mA AT _.__ fps<br />

20 mA AT _.__ fps<br />

(0.000-9999)<br />

Repeat for each channel<br />

Repeat for each channel<br />

A. Factory installed option. Requires B1 hardware or newer.<br />

B. Requires factory-installed Dialout Modem and B2 hardware or newer.<br />

1.<br />

2.<br />

3.<br />

DIALOUT NUMBERS:<br />

__ MINUTE<br />

DELAY BETWEEN CALLS<br />

(0-99)<br />

ANALOG OUPUT _:<br />

LEVEL VELOCITY<br />

FLOW NONE<br />

ANALOG OUTPUT _:<br />

0-TO-20 mA<br />

4-TO-20 mA<br />

ANALOG OUTPUT _:<br />

0 mA AT _.__ fps<br />

20 mA AT _.__ fps<br />

(0.000-9999)<br />

SERIAL OUTPUT EVERY:<br />

15 SEC 1 MIN<br />

5 MIN 15 MIN<br />

When DECIMAL POINT key is pressed<br />

SELECT CODE:<br />

, # *

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!