<strong>6700</strong> SAMPLERS<br />

Figure 45 Extended Programming: YSI 600 Screens<br />

From Figures 43 and 44, Extended<br />

Programming Hardware Screens.<br />

D O YO U H AV E A<br />

YSI 600 CONNECTED?<br />

YES NO<br />

TEST YSI 600<br />

COMMUNICATIONS?<br />

YES NO<br />

NO<br />

DO YOU WANT<br />

pH DATA?<br />

YES NO<br />

DO YOU WANT<br />

D.O. DATA?<br />

YES NO<br />

DO YOU WANT<br />

CONDUCTIVITY DATA?<br />

YES NO<br />

DO YOU WANT<br />

TEMPERATURE DATA?<br />

YES NO<br />

If applicable<br />

NEW HARDWARE SETUP--<br />

STORED DATA WILL<br />

BE LOST! OK?<br />

YES NO<br />

SELECT PARAMETER<br />

TO CALIBRATE<br />

Y-pH Y-D.O. Y-COND<br />

DONE<br />

Y-pH<br />

pH CALIBRATION:<br />

pH04 and pH07<br />

pH07 and pH10<br />

pH04, pH07 and pH10<br />

RINSE PROBE, THEN<br />

PLACE IN pH__BUFFER<br />

PRESS WHEN STABLE<br />

__.__<br />

PLEASE WAIT!<br />

If applicable<br />

CALIBRATION READING<br />

OUT OF RANGE!<br />

OVERRIDE?<br />

YES NO<br />

YES<br />

YES<br />

YES<br />

YES<br />

NO<br />

Y-D.O.<br />

See Note<br />

SELECT DATA TYPE:<br />

SPECIFIC CONDUCTANCE<br />

SALINITY T.D.S.<br />

CONDUCTIVITY DONE<br />

CALIBRATION METHOD:<br />

D.O. STANDARD<br />

BAROMETRIC PRESSURE<br />

ALTITUDE<br />

Y-COND<br />

Y-SAL<br />

Y-TDS<br />

Y-SP CO<br />

REPEAT<br />

FOR<br />

ALL pH<br />

BUFFERS<br />

TEST YSI 600<br />

COMMUNICATIONS?<br />

YES NO<br />

ENTER THE SPECIFIC<br />

CONDUCTANCE OF YOUR<br />

KCl STANDARD<br />

____mS/cm<br />

PLACE PROBE IN<br />

____mS/cm STANDARD<br />

PRESS WHEN STABLE<br />

____mS/cm<br />

PLEASE WAIT!<br />

If applicable<br />

CALIBRATION READING<br />

OUT OF RANGE!<br />

OVERRIDE?<br />

YES NO<br />

131<br />

WARNING!<br />

DO NOT REMOVE<br />

YSI 600 POWER<br />

... TESTING<br />

SPECIFIC CONDUCTANCE<br />

TEMP. COEFFICIENT:<br />

_.__%/C<br />

(1.50-2.50)<br />

T.D.S. SCALE FACTOR:<br />

_.__<br />

(0.55-0.90)<br />

PLEASE WAIT! PARTITION MEMORY<br />

WILL LAST __ DAYS<br />

ENTER THE D.O.<br />

CONTENT OF YOUR<br />

CALIBRATION STANDARD<br />

__._ mg/l<br />

ENTER THE ABSOLUTE<br />

BAROMETRIC PRESSURE<br />

____ mm Hg<br />

ENTER YOUR<br />

ALTITUDE<br />

_____ ft<br />

NO<br />

NO<br />

COMMUNICATIONS RATE<br />

SET AT 2400 BAUD<br />

PLACE PROBE IN<br />

CALIBRATION CUP<br />

PRESS WHEN STABLE<br />

___mg/l ___ F<br />

PLEASE WAIT!<br />

If applicable<br />

CALIBRATION READING<br />

OUT OF RANGE!<br />

OVERRIDE?<br />

YES NO<br />

D.O. CALIBRATED TO:<br />

___.__ mg/l<br />

Note<br />

Conductivity Units:<br />

Salinity = parts-per-thousand<br />

T.D.S. = grams/liter<br />

Specific Conductance = mS/cm<br />

Conductivity = mS/cm<br />

PLACE PROBE IN<br />

__._ mg/l STANDARD<br />

PRESS WHEN STABLE<br />

___mg/l ___ F