<strong>6700</strong> SAMPLERS<br />

Figure 44 Extended Programming: Hardware Quick View Screens<br />

RUN "ISCO <strong>6700</strong> "<br />

PROGRAM<br />

VIEW REPORT<br />

OTHER FUNCTIONS<br />

MAINTENANCE<br />

MANUAL FUNCTIONS<br />

PROGRAMMING STYLE<br />

HARDWARE<br />

YSI 600<br />

Y-pH Y-D.O. Y-COND<br />

Y-TEMP<br />

MASTER/SLAVE ON<br />

BTL FULL DETECT OFF<br />

TIMED BACKLIGHT<br />

PGM LOCK ENABLED<br />

EVENT MARK SENT<br />

WHILE<br />

PUMPING FORWARD<br />

PUMP COUNTS FOR<br />

EACH PURGE CYCLE:<br />

____ PRE-SAMPLE<br />

____ POST-SAMPLE<br />

I/O1=I/O ENABLE<br />

I/O2=PGM RUNNING<br />

I/O3=PROGRAM DONE<br />

See Note A.<br />

LIQUID DETECTION<br />

0.01 inch TIP<br />

RAIN GAGE<br />

NO YSI SONDE<br />

YSI 600<br />

OTHER YSI SONDE<br />

MASTER/SLAVE?<br />

YES NO<br />

BACKLIGHT ALWAYS OFF<br />

TIMED BACKLIGHT<br />

CONTINUOUS BACKLIGHT<br />

CHANGE PASSWORD TO<br />

_____<br />

EVENT MARK SENT FOR<br />

EVERY SAMPLE<br />

COMPLETE SAMPLES<br />

PRE-SAMPLE PURGE:<br />

____ COUNTS<br />

(10-9999)<br />

POST-SAMPLE PURGE:<br />

DEPENDENT ON HEAD<br />

FIXED COUNT<br />

See Note B.<br />

SET I/Ox:<br />

NONE<br />

PGM ENABLED<br />

-> 'A' ENABLED<br />

-> 'B' ENABLED<br />

-> PROGRAM DONE<br />

-> 'A' DONE<br />

-> 'B' DONE<br />

-> RUN ERROR<br />

-> FLOW THRU<br />

-> CONDITIONS<br />

See Figure 48, Analog Output and Dialout<br />

Quick View Screens.<br />

Notes<br />

130<br />

USE LIQUID DETECTOR?<br />

YES NO<br />

D O YO U H AV E A<br />

RAIN GAGE CONNECTED?<br />

YES NO<br />

NO<br />

See Note A.<br />

BOTTLE FULL DETECT?<br />

YES NO<br />

REENTER NEW PASSWORD<br />

_____<br />

EVENT MARK DURATION<br />

3 SECONDS<br />

WHILE PUMPING<br />

POST-SAMPLE PURGE:<br />

____ COUNTS<br />

(10-9999)<br />

YES<br />

RAIN GAGE<br />

0.01 inch TIP<br />

0.1mm TIP<br />

NEW HARDWARE<br />

If applicable<br />

SETUP--<br />

STORED DATA WILL<br />

BE LOST! OK?<br />

YES NO<br />

See Figure 45, Extended Programming:<br />

YSI 600 Screens, on page 131.<br />

See Figure 46, Extended Programming:<br />

Optional YSI Screens, on page 132.<br />

NEW HARDWARE SETUP--<br />

STORED DATA WILL<br />

BE LOST! OK?<br />

YES NO<br />

RUN FLOW THRU PUMP<br />

___SECONDS BEFORE<br />

TAKING READINGS<br />

(0-120)<br />

AT THE BEGINNING OF:<br />

INITIAL PURGE<br />

FORWARD PUMPING<br />

DURING:<br />

ENTIRE PUMP CYCLE<br />

FORWARD PUMPING<br />

See Figure 42, Extended Programming: Quick<br />

View; Programmed <strong>Sampler</strong> Enable.<br />

A. Option only appears when the program option is activated. See<br />

Chapter 6.<br />

B. denotes output signal.