6700 Portable Sampler User Manual - Isco
6700 Portable Sampler User Manual - Isco
6700 Portable Sampler User Manual - Isco
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>6700</strong> SAMPLERS<br />
Figure 41 Extended Programming: Quick View; Pacing and Distribution<br />
Continued from Figure 40, Extended<br />
Programming: Quick View; Equipment Set-<br />
Up, on page 126.<br />
PACING:<br />
TIME, EVERY<br />
__ HOURS, __ MINUTES<br />
DISTRIBUTION:<br />
__ BOTTLES/SAMPLE<br />
___ SAMPLES/BOTTLE<br />
RUN CONTINUOUSLY<br />
VOLUME<br />
____ ml SAMPLES<br />
UNIFORM TIME PACED<br />
FLOW PACED<br />
EVENT PACED<br />
NONUNIFORM TIME<br />
NONUNIFORM TIME:<br />
CLOCK TIMES<br />
INTERVALS IN MINUTES<br />
RANDOM INTERVALS<br />
PROGRAM RUN TIME:<br />
__ HOURS, __ MINUTES<br />
__ BOTTLES PER<br />
SAMPLE EVENT (1-max)<br />
Multi-bottle<br />
1 bottle<br />
RUN CONTINUOUSLY?<br />
YES NO<br />
Uniform Time Paced Only<br />
DO YOU WANT<br />
SAMPLE VOLUMES<br />
DEPENDENT ON FLOW?<br />
YES NO<br />
See Figure 42, Extended Programming: Quick<br />
View; Programmed <strong>Sampler</strong> Enable, on<br />
page 128.<br />
FIRST SAMPLE AT<br />
START TIME,<br />
THEN ...<br />
SWITCH BOTTLES EVERY<br />
__ HOURS, __ MINUTES<br />
No<br />
No<br />
Yes<br />
127<br />
TIME BETWEEN<br />
SAMPLE EVENTS:<br />
__ HOURS, __ MINUTES<br />
PACED BY:<br />
FLOW PULSES<br />
FLOW MODULE VOLUME<br />
TAKE SAMPLES AT:<br />
1. START TIME<br />
2. HH:MM<br />
3. HH:MM<br />
SWITCH BOTTLES ON:<br />
NUMBER OF SAMPLES<br />
TIME<br />
TAKE ___ SAMPLES<br />
(1-999)<br />
FLOW PULSES<br />
FLOW MODULE VOLUME<br />
SAMPLE VOLUME:<br />
___ ml (10-max)<br />
QUANTITY AT INTERVAL<br />
1. __ AT ___ MIN<br />
2. __ AT ___ MIN<br />
3. __ AT ___ MIN<br />
FIRST SWITCH TIME<br />
AT __:__<br />
FLOW BETWEEN<br />
SAMPLE EVENTS:<br />
____ PULSES (1-9999)<br />
SAMPLE AT START?<br />
YES NO<br />
SWITCH BOTTLES EVERY<br />
___ SAMPLES (1-max)<br />
RUN CONTINUOUSLY?<br />
YES NO<br />
SAMPLE VOLUME:<br />
10 ML FOR EVERY<br />
___ PULSES