22.03.2013 Views

6700 Portable Sampler User Manual - Isco

6700 Portable Sampler User Manual - Isco

6700 Portable Sampler User Manual - Isco

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>6700</strong> SAMPLERS<br />

Figure 38 Extended Programming: Programmed <strong>Sampler</strong> Enable<br />

Continued from Figure 37, Extended Programming:<br />

Pacing and Distribution, on page 123.<br />

'A' DONE<br />

RAIN<br />

"RAIN" SET POINT:<br />

__.__ INCHES PER<br />

15 MIN 30 MIN<br />

1 HOUR 2 HOURS<br />

ENABLED WHEN:<br />

ABOVE SET POINT<br />

BELOW SET POINT<br />

RESET RAIN HISTORY?<br />

YES NO<br />

Repeat<br />

See Note B.<br />

NONE<br />

PAUSE RESUME<br />

1.HH:MM DD HH:MM DD<br />

2.HH:MM DD HH:MM DD<br />

CLEAR DONE<br />

See Note A.<br />

ENABLE:<br />

I/O RAIN LEVEL<br />

FLOW Y-pH Y-TEMP<br />

Y-COND Y-D.O. NONE<br />

REPEAT<br />

FOR<br />

SECOND<br />

TYPE<br />

ONCE ENABLED,<br />

STAY ENABLED?<br />

YES NO<br />

See Figure 27, Standard and Extended<br />

Programming: Start Times, on page 114.<br />

All except<br />

NONE<br />

If applicable<br />

PAUSE & RESUMEs<br />

MUST BE ENTERED<br />

IN PAIRS!<br />

ENABLED WHEN:<br />

I/O ENABLE IS HIGH<br />

I/O ENABLE IS LOW<br />

If applicable If applicable<br />

No<br />

Ye s<br />

SAMPLE AT DISABLE?<br />

YES NO<br />

SAMPLE AT ENABLE?<br />

YES NO<br />

Ye s<br />

START OF SAMPLING<br />

AFTER A<br />

___ MINUTE DELAY<br />

(0-999)<br />

Notes<br />

124<br />

Continued from Figure 43, Extended Programming:<br />

Hardware Screens, on page 129.<br />

ENABLE: RAIN<br />

AND OR DONE<br />

'A' Done and I/O are not options for I/O Conditions<br />

DONE<br />

"LEVEL" RANGE:<br />

LOWER:_.__ft<br />

UPPER:_.__ft<br />

(0.001-30.000)<br />

ENABLED WHEN:<br />

INSIDE RANGE<br />

OUTSIDE RANGE<br />

SAMPLE AT RESUME?<br />

YES NO<br />

AND<br />

or OR<br />

SAMPLE AT ENABLE?<br />

YES NO<br />

ENABLE: RAIN AND<br />

I/O LEVEL FLOW<br />

Y-pH Y-TEMP Y-COND Y-D.O.<br />

NONE<br />

I / O All except I/O, Rain, and 'A' Done<br />

CHECK ENABLE EVERY<br />

0 . 5 1 2 5<br />

10 15 30<br />

MINUTES<br />

No<br />

"LEVEL" CONDITION:<br />

SET POINT<br />

RANGE<br />

RESET SAMPLE<br />

INTERVAL AT ENABLE?<br />

YES NO<br />

Ye s<br />

See Note A.<br />

"LEVEL" SET POINT:<br />

_.__ft<br />

(0.001-30.000)<br />

ENABLED WHEN:<br />

ABOVE SET POINT<br />

BELOW SET POINT<br />

No<br />

CONTINUE COUNTDOWN<br />

WHILE DISABLED?<br />

YES NO<br />

A. All valid enable options will be shown. Enable options may include:<br />

LEVEL, FLOW, pH, TEMP, PERCENT, VEL, RAIN, I/O, 'A'DONE<br />

FR-TEMP, Y-TEMP, Y-COND, Y-SP_CO, Y-TDS, Y-SAL, Y-DO,<br />

Y-pH, Y-ORP, Y-LEVEL, Y-NH4, Y-NH3, Y-NO3, Y-TURB, Y-Cl,<br />

Y-FLOW<br />

B. YES = Latched or Stay Enabled<br />

NO = Repeatable Enable

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!