Note<br />

When updating the Flash<br />

memory, power must be<br />

applied to the sampler.<br />

<strong>6700</strong> SAMPLERS<br />

If you need to collect sampling results and partition data, do this<br />

before allowing the sampler to create and size the partitions. The<br />

stored data is lost as the sampler reformats its memory. As a<br />

precaution, the sampler displays the screen below.<br />

When YES is selected, the sampler clears the stored data and<br />

reformats the memory partitions. The sampler then displays the<br />

new capacity of the partition memory.<br />

If the duration is too short, try changing the data storage interval<br />

or eliminating unnecessary reading types in the Hardware or<br />

Module Setup. For example, a sampler configured with a 730 Bubbler<br />

Module and a rain gauge storing data at a one-minute interval,<br />

creates level and rainfall partitions that hold 13 days of<br />

readings. Changing the storage interval to two minutes extends<br />

the storage capacity to 26 days.<br />

The sampler does not have to be running a program to store<br />

readings. When the sampler is on, it stores readings at the<br />

selected data storage interval. Once the partition is filled, the<br />

readings roll over.<br />

When the sampler is running a program, the partitions become<br />

“triggered” by the programmed start time or the first enable<br />

time, whichever is later. A triggered partition continues to log<br />

readings at the selected interval, but will not replace any readings<br />

taken after the trigger event. The sampler fills the partition<br />

and then stops recording to preserve the data. The first reading<br />

preserved in a full partition is one hour before the trigger event.<br />

A full partition can be reset by starting another program or<br />

changing storage parameters.<br />

If you require continuous readings for analysis, be sure to collect<br />

the readings before the partition fills or rolls over to avoid gaps<br />

in the data.<br />

<strong>Isco</strong> offers a <strong>6700</strong> sampler controller with an expanded memory<br />

capacity. Instead of the standard 128 kilobytes, this controller has<br />

4 megabytes of RAM available for program and data storage. Contact<br />

the factory or your sales representative for more information.<br />

FLASH MEMORY AND SOFTWARE UPGRADES<br />

The sampler has Flash memory to store its software. With Flash<br />

technology, you can upgrade your sampler’s software without<br />

sending it back to the factory or replacing a chip. Simply connect<br />

a computer to the sampler and run the Flash Update program.<br />

102<br />

INTERVAL CHANGED --<br />

STORED DATA WILL<br />

BE LOST! OK?<br />

YES NO<br />

PARTITION MEMORY<br />

WILL LAST 13 DAYS