ings codes for wood structural panels used to resist seismic forces without<br />
further reduction in design values. Two walls of each sheathing material<br />
were tested under both monotonic and cyclic loading. All walls in this<br />
study incorporated the use of overturning anchors in the form of mechanical<br />
hold-downs. The monotonic tests were conducted according to ASTM<br />
E564, while the cyclic tests were conducted to the recently adopted ASTM<br />
standard E2126. A comparison of the monotonic and cyclic tests leads to<br />
several key dissimilarities. In general, the performance of the shear walls<br />
when tested cyclically decreased, although the degree of reduction depends<br />
on the sheathing material. Hardboard panels tested under cyclic<br />
loading performed similar to the monotonic tests. The peak load during<br />
cyclic tests was actually larger than its corresponding monotonic test. Fiberboard<br />
panels also performed in a similar manner when tested under cyclic<br />
and monotonic loading. OSB panels did not perform as well when<br />
subjected to cyclic loading. The peak load was reduced by 12%, and the<br />
energy dissipation was 27% lower when tested under cyclic loading. Gypsum<br />
panels performed poorly under cyclic loading. Peak load reduction<br />
was 16%, failure displacement decreased by 38mm (1.5 in.), and the<br />
amount of energy dissipation was nearly reduced by one-half when subjected<br />
to cyclic loading.<br />
Conclusions<br />
A total of 31 walls were tested during this study to determine and compare<br />
the effects of monotonic and cyclic loading on shear walls with various<br />
sheathing materials. The sheathing materials investigated are oriented<br />
strand board (OSB), hardboard, fiberboard, and gypsum wallboard. All of<br />
the walls were 1.2 x 2.4 m (4 x 8 ft), and to be conservative there were no<br />
gravity loads applied to the walls. All of the tests were performed with<br />
hold-downs. Monotonic tests were performed according to ASTM E564,<br />
while the cyclic tests were performed according to ASTM E2126. The<br />
conclusions drawn from the cyclic tests are:<br />
(1) In general, the performance parameters decreased when the cyclic<br />
tests were compared to the monotonic tests. The most drastic reduction<br />
was observed during the gypsum-sheathed tests, followed by the<br />
OSB-sheathed tests.<br />
(2) Hardboard panels tested under cyclic loading performed similar to the<br />
monotonic tests. The peak load during cyclic tests was actually larger<br />
than its corresponding monotonic test (8%). The displacement at fail-<br />
ure decreased by 9%, and the energy dissipation was reduced by only<br />
4% when subjected to cyclic loading.<br />
(3) Fiberboard panels also performed in a similar manner when tested under<br />
cyclic and monotonic loading. The peak load only decreased by<br />
0.27 kN (0.06 kips), which was a reduction of 4%. The displacement<br />
at failure decreased by 7%, and the energy dissipation was reduced by<br />
5% when subjected to cyclic loading.<br />
(4) OSB panels tested cyclically did not perform as well as when tested<br />
monotonically. The peak load reduction was 1.33 kN (0.3 kips), or<br />
12%, and the energy dissipation was 27% lower when tested under<br />
cyclic loading.<br />
(5) Gypsum panels performed poorly under cyclic loading. The peak load<br />
reduction was 16%, the failure displacement decreased by 38mm (1.5<br />
in.), and the amount of energy dissipation was nearly reduced by onehalf<br />
when subjected to cyclic loading.<br />
37-15-1 M Yasumura, M Uesugi, L Davenne<br />
Estimating 3D behavior of conventional timber structures with shear<br />
walls by pseudodynamic tests<br />
Abstract<br />
One of the most important causes of the seismic damage of timber buildings<br />
is the unbalance of the lateral resistance of shear walls and the lack<br />
of the shear stiffness of the horizontal diaphragm. These damages were often<br />
observed during the 1995 Hyogoken-Nanbu Earthquake on conventional<br />
commercial buildings that had large openings in front of the building.<br />
The objective of this research is to analyse the influence of the unbalance<br />
of the lateral resistance of shear walls and the shear stiffness of the<br />
horizontal diaphragm on 3D dynamic behaviour of the structures by pseudo-dynamic<br />
tests. The specimens were conventional post and beam timber<br />
structures with shear walls of 3m width, 3 m depth and 3m height. Specimens<br />
had 7.5 mm plywood sheathed shear walls and a horizontal diaphragm<br />
sheathed with 24mm thick plywood. There were two types of horizontal<br />
diaphragms, i.e., the rigid diaphragm in which all the perimeters of<br />
plywood sheathings were nailed and the semi-rigid one that were only<br />
nailed in transversal direction. Four specimens with different combination<br />
of shear walls and diaphragms were prepared. Specimens WW-R and<br />
WW-S had shear walls with window opening in both loading direction and<br />
<strong>CIB</strong>-<strong>W18</strong> Timber Structures – A review of meeting 1-43 5 SPECIAL ACTIONS page 5.22