<strong>Spiegelberg</strong>: <strong>CSF</strong>-<strong>Drainage</strong> Products<br />
Technology<br />
for<br />
Brains<br />
1
2<br />
Contents<br />
Antimicrobial Shunt Catheters<br />
External Ventricular <strong>Drainage</strong> Catheters<br />
Accessories<br />
Antimicrobial External Ventricular<br />
<strong>Drainage</strong> Catheters<br />
Antimicrobial Lumbar <strong>Drainage</strong><br />
Catheter<br />
Antimicrobial Subdural <strong>Drainage</strong><br />
Catheters<br />
External Ventricular <strong>Drainage</strong> Kit<br />
External Ventricular <strong>Drainage</strong> Kit with<br />
Plate<br />
External Ventricular <strong>Drainage</strong> Bag<br />
EVD-Holders<br />
Scientific Information about Silverline ®<br />
Technology<br />
Catheter Reference Chart<br />
3<br />
4<br />
5<br />
6<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
15<br />
16
Antimicrobial Ventricular Shunt Catheter<br />
Antimicrobial Peritoneal Shunt Catheter Indication<br />
Silverline Shunt Catheters are<br />
indicated to be used in all patients<br />
with an indication for internal <strong>CSF</strong>drainage.<br />
The trocar is used for<br />
tunneling the catheter.<br />
The catheter has<br />
numbered depth marks.<br />
The peritoneal catheter<br />
is made of two layers.<br />
The antiseptic<br />
radiopaque inner layer<br />
prevents colonization<br />
under the influence of<br />
<strong>CSF</strong> in an optimal way.<br />
The outer layer is made<br />
of pure silicone. The<br />
antiseptic effect is<br />
achieved by diffusion of<br />
silver ions from the inner<br />
layer. The pure silicone<br />
prevents micro fractures<br />
and calcification.<br />
Product Description<br />
Silverline Ventricular Shunt Catheters<br />
are made of antiseptic radiopaque<br />
implant grade silicone. They have<br />
numbered centimeter marks. A stylet<br />
and a trocar are delivered with the<br />
catheter.<br />
Silverline Peritoneal Shunt Catheters<br />
are made of two layers. The inner<br />
layer is made of antiseptic radiopaque<br />
implant grade silicone. The<br />
outer layer is made of pure silicone.<br />
By this construction prevention of<br />
micro- fractures and calcification is<br />
achieved.<br />
Silverline Shunt Catheters are<br />
compatible with all manufacturers´<br />
shunt valves.<br />
Technical Information<br />
The stylet is used to<br />
introduce the catheter<br />
into the ventricle.<br />
Silverline Antimicrobial Ventricular Shunt Catheter<br />
REF IVD 30.070.02<br />
Length 230 mm<br />
Silverline Antimicrobial Peritoneal Shunt Catheter<br />
REF IVD 30.080.02<br />
Length 1200 mm<br />
Set Consisting of Ventricular and Peritoneal Catheter<br />
REF IVD 30.401.02<br />
Outer Diameter 2.5 mm<br />
Inner Diameter 1.3 mm<br />
Material Silicone<br />
Shelf Life 3 Years<br />
Duration of use Long term implantable<br />
Compatible with All shunt valves designed for<br />
silicone catheters 1.3 mm ID<br />
Shelf Life 3 years<br />
Duration of use Long term<br />
implantable<br />
EO sterile<br />
Latex free<br />
3
4<br />
External Ventricular <strong>Drainage</strong> Catheters<br />
Indication<br />
External Ventricular <strong>Drainage</strong><br />
Catheters are indicated for<br />
perioperative <strong>CSF</strong>-drainage, for<br />
treatment of Subarachnoid<br />
Hemorrhage (SAH), treatment of<br />
elevated Intracranial Pressure (ICP),<br />
and whenever <strong>CSF</strong>-drainage is<br />
indicated for up to 30 days.<br />
Ventricular Catheter<br />
REF 8F EVD 30.010.01/FV804<br />
Outer Diameter 2.7 mm<br />
Inner Diameter 1.5 mm<br />
REF 10F EVD 30.030.01<br />
Outer Diameter 3.3 mm<br />
Inner Diameter 1.9 mm<br />
Material Polyurethane<br />
Length 270 mm<br />
Shelf Life 3 years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
Ventricular Catheter with Hollow<br />
Stylet 8F ‘Heese’<br />
The hollow stylet is equipped with holes<br />
that correspond to the holes in the<br />
catheter. Flow of <strong>CSF</strong> out of the stylet<br />
indicates a correct position in the<br />
ventricle. A turn of 90 degrees of the<br />
stylet shuts off the flow of <strong>CSF</strong>.<br />
REF EVD 30.012.01<br />
Material Polyurethane<br />
Outer Diameter 2.7 mm<br />
Inner Diameter 1.5 mm<br />
Length 200 mm<br />
Shelf Life 3 years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
Short Ventricular Catheter 8F<br />
The Short Ventricular Catheter is used<br />
whenever tunneling is not desired. This<br />
will reduce the time for the procedure<br />
significantly.<br />
REF EVD 30.011.01<br />
Material Polyurethane<br />
Outer Diameter 2.7 mm<br />
Inner Diameter 1.5 mm<br />
Length 100 mm<br />
Shelf Life 3 years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
Product Description<br />
The catheters are made of radiopaque<br />
polyurethane. Their round tip<br />
is closed. They have numbered<br />
centimeter marks. Stylet, trocar,<br />
Luer-Lock connector, and suturing<br />
wing are delivered with the catheter.<br />
The catheter is outfitted<br />
with lettered marks.<br />
The trocar is used for<br />
tunneling.<br />
The Luer-Lock<br />
connector for the<br />
connection with the<br />
EVD-Kit is attached to<br />
the catheter.<br />
The slitted suturing wing<br />
is used for fixation to the<br />
skin.<br />
<strong>CSF</strong> is released through<br />
the hollow stylet when<br />
the ventricle is<br />
punctured.<br />
The Luer-Lock connector<br />
is connected to the<br />
external ventricular<br />
drainage kit.<br />
The stylet is used for<br />
stiffening during<br />
insertion.
External Ventricular <strong>Drainage</strong><br />
Catheter with Cranial Bolt<br />
The ventricular catheter is fixed in<br />
the bone by means of a bolt. After<br />
making a burr hole and opening the<br />
dura the probe is placed in the<br />
ventricle with the bolt in place in the<br />
upper region of the catheter.<br />
The catheter has two<br />
sets of numbered depth<br />
marks. The first set is<br />
related to the tip of the<br />
catheter.<br />
The drill bit has an<br />
adjustable stop.<br />
The Allen wrench ist<br />
used to adjust the stop.<br />
The dura opener is used<br />
to perforate the dura<br />
mater.<br />
Accessories<br />
With the clamping nut<br />
the probe is fixed in the<br />
bolt.<br />
Then the bolt is slid down to the<br />
burr hole and screwed into the<br />
bone. Finally the probe is fixed in the<br />
bolt with the clamping nut. The<br />
Luer-Lock connector is placed in the<br />
drainage tube and connected to a<br />
drainage kit.<br />
The second set of depth<br />
marks is related to the<br />
upper edge of the bolt.<br />
Manometer Tube<br />
The manometer tube is used to<br />
determine the opening pressure. It is<br />
connected to the hollow stylet of a<br />
Heese-Catheter. Opening pressure can<br />
then be observed from the liquid level. The manometer tube is<br />
outfitted with lettered<br />
marks.<br />
The stylet is used to<br />
introduce the catheter<br />
into the ventricle.<br />
The Luer-Lock connector<br />
adapts the catheter to<br />
the EVD-Kit.<br />
REF 8F EVD 30.014.01<br />
Outer Diameter 2.7 mm<br />
Inner Diameter 1.5 mm<br />
REF 10F EVD 30.034.01<br />
Outer Diameter 3.3 mm<br />
Inner Diameter 1.9 mm<br />
Material Polyurethane<br />
Length 270 mm<br />
Shelf Life 3 Years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
REF EVD 30.013.01<br />
Material Polyurethane<br />
Outer Diameter 2.7 mm<br />
Inner Diameter 1.6 mm<br />
Length 420 mm<br />
Shelf Life 3 years<br />
Duration of use transient, up to<br />
60 minutes<br />
EO sterile<br />
Latex free<br />
5
6<br />
Antimicrobial External Ventricular <strong>Drainage</strong> Catheters<br />
Indication<br />
Silverline External Ventricular <strong>Drainage</strong><br />
Catheters are indicated for<br />
perioperative <strong>CSF</strong>-drainage, for<br />
treatment of Subarachnoid<br />
Hemorrhage (SAH), treatment of<br />
elevated Intracranial Pressure (ICP),<br />
and whenever <strong>CSF</strong>-drainage is<br />
indicated for up to 30 days.<br />
Silverline<br />
Antimicrobial Ventricular Catheter<br />
REF Polyurethane 6F EVD 30.020.02<br />
Outside Diameter 2 mm<br />
Inside Diameter 1 mm<br />
REF Polyurethane 8F EVD 30.010.02<br />
REF Silicone 8F EVD 30.050.02<br />
Outside Diameter 2.7 mm<br />
Inside Diameter 1.5 mm<br />
REF Polyurethane 10F EVD 30.030.02<br />
Outside Diameter 3.3 mm<br />
Inside Diameter 1.9 mm<br />
Length 270 mm<br />
Shelf Life 3 years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
Silverline<br />
Antimicrobial<br />
Ventricular Catheter with<br />
Hollow Stylet ‘Heese’<br />
REF 8F EVD 30.012.02<br />
Outside Diameter 2.7 mm<br />
Inside Diameter 1.5 mm<br />
REF 10F EVD 30.032.02<br />
Outside Diameter 3.3 mm<br />
Inside Diameter 1.9 mm<br />
Material Polyurethane<br />
Length 200 mm<br />
Shelf Life 3 years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
Product Description<br />
The catheters have a closed round<br />
tip. They have numbered centimeter<br />
marks. Stylet, trocar, Luer-Lock<br />
connector, and suturing wing are<br />
delivered with the catheter.<br />
The catheters are available either<br />
made of radiopaque antiseptic<br />
polyurethane, or of radiopaque<br />
antiseptic silicone.<br />
The catheter has<br />
numbered depth marks.<br />
The trocar is used for<br />
tunneling the catheter.<br />
The slitted suturing wing<br />
is used for the fixation to<br />
the skin.<br />
The Luer-Lock connector<br />
adapts the catheter to<br />
the EVD-Kit.<br />
The stylet is used to<br />
introduce the catheter<br />
into the ventricle.<br />
<strong>CSF</strong> is released through<br />
the hollow stylet when<br />
the ventricle is<br />
punctured.
Silverline<br />
Antimicrobial<br />
Short Ventricular Catheter 8F<br />
Silverline Antimicrobial<br />
Ventricular Catheter with<br />
Cranial Bolt<br />
The ventricular catheter is fixed in<br />
the bone by means of a bolt. After<br />
making a burr hole and opening the<br />
dura the catheter is placed in the<br />
ventricle with the bolt in place in the<br />
The catheter has two<br />
sets of numbered depth<br />
marks. The first set is<br />
related to the tip of the<br />
catheter.<br />
The drill bit has an<br />
adjustable stop.<br />
The Allen wrench is used<br />
to adjust the stop.<br />
The dura opener is used<br />
to perforate the dura<br />
mater.<br />
With the clamping nut<br />
the probe is fixed in the<br />
bolt.<br />
The Luer-Lock<br />
connector for the<br />
connection with the<br />
EVD-Kit is attached to<br />
the catheter.<br />
upper region of the probe.<br />
Then the bolt is slid down to the<br />
burr hole and screwed into the<br />
bone. Finally the catheter is fixed in<br />
the bolt with the clamping nut. The<br />
Luer-Lock connector is placed in the<br />
drainage tube and connected to a<br />
drainage kit.<br />
The second set of depth<br />
marks is related to the<br />
upper edge of the bolt.<br />
REF EVD 30.011.02<br />
Material Polyurethane<br />
Outside Diameter 2.7 mm<br />
Inside Diameter 1.5 mm<br />
Length 100 mm<br />
Shelf Life 3 years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
REF 8F EVD 30.014.02<br />
Outer Diameter 2.7 mm<br />
Inner Diameter 1.5 mm<br />
REF 10F EVD 30.034.02<br />
Outer Diameter 3.3 mm<br />
Inner Diameter 1.9 mm<br />
Material Polyurethane<br />
Length 270 mm<br />
Shelf Life 3 Years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
The Luer-Lock connector<br />
adapts the catheter to<br />
the EVD-Kit.<br />
The stylet is used to<br />
introduce the catheter<br />
into the ventricle.<br />
7
8<br />
Antimicrobial Lumbar <strong>Drainage</strong> Catheter<br />
Indication<br />
Silverline Lumbar <strong>Drainage</strong> Catheters<br />
are indicated for perioperative <strong>CSF</strong>drainage,<br />
for diagnosis of Normal<br />
Pressure Hydrocephalus (NPH), and<br />
whenever lumbar <strong>CSF</strong>-drainage is<br />
indicated for up to 30 days.<br />
Product Description<br />
The catheters are made of radiopaque<br />
antiseptic polyurethane. Their<br />
round tip is closed. They have<br />
numbered centimeter marks. Tuohy<br />
Needle, Luer-Lock connector, and<br />
suturing wing are delivered with the<br />
catheter.<br />
The catheter has labelled<br />
depth marks.<br />
The catheter is<br />
introduced by means of<br />
the Tuohy Needle.<br />
The butterfly suturing<br />
wing is used to fix the<br />
catheter to the skin.<br />
Scientific Information<br />
A prospective study of the University<br />
of Frankfurt shows a lower rate of<br />
vasospasm with lumbar drainage<br />
applied in patients with<br />
Subarachnoid Hemorrhage (SAH).<br />
Reference<br />
Tizi, K.; E. Güresir ; J. Beck; A. Raabe;<br />
V. Seifert ; H. Vatter: The effect of<br />
lumbar drainage on cerebral<br />
vasospasm and infarction after<br />
subarachnoid haemorrhage. DGNC<br />
Annual Meeting 2009 Abstracts,<br />
German Medical Science GMS<br />
Publishing House; 2009., http://<br />
www.egms.de/en/meetings/<br />
dgnc2009/09dgnc141.shtml<br />
The connector is used<br />
for connection with the<br />
drainage kit. It is secured<br />
with a clamping nut.<br />
Silverline<br />
Antimicrobial<br />
Lumbar <strong>Drainage</strong><br />
Catheter<br />
REF ELD 33.010.02<br />
Material Polyurethane<br />
Outer Diameter 1.6 mm<br />
Inner Diameter 0.8 mm<br />
Length 800 mm<br />
Shelf Life 3 years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free
Antimicrobial Subdural <strong>Drainage</strong> Catheters<br />
Indication<br />
Silverline Subdural <strong>Drainage</strong><br />
Catheters are indicated for drainage<br />
after evacuation of Chronic Subdural<br />
Hematoma (CSH).<br />
Product Description<br />
The catheters are made of radiopaque<br />
antiseptic polyurethane. They<br />
are available in two different<br />
diameters. The catheters have a 6 cm<br />
perforation zone close to the tip. Stylet,<br />
trocar, Luer-Lock connector, and<br />
suturing wing are delivered with the<br />
catheter.<br />
The trocar is used for<br />
tunneling the catheter.<br />
Scientific Information<br />
A prospective randomized study<br />
shows a lower recurrence rate, lower<br />
mortality, and better outcome with<br />
drainage applied for 48 hours after<br />
surgical evacuation of the CSD.<br />
The catheter has<br />
numbered depth marks.<br />
The slitted suturing wing<br />
is used for the fixation to<br />
the skin.<br />
Reference<br />
Santarius, T.; Kirkpatrick, P.;<br />
Ganesan, D.; Chia, H.; Jalloh, I.;<br />
Marcus, H.; Smielewski, P.; Price, S.;<br />
Kirollos, R.; Hutchinson, P.:<br />
Randomised controlled trial of the<br />
use of drains versus no drains after<br />
burr hole evacuation of chronic<br />
subdural haematoma. Neurosurgery:<br />
August 2009 - Volume 65 - Issue 2 -<br />
p 401, doi: 10.1227<br />
01.neu.0000358671.05488.a2<br />
Silverline<br />
Antimicrobial Subdural<br />
<strong>Drainage</strong> Catheter<br />
The Luer-Lock connector<br />
adapts the catheter to<br />
the EVD-Kit.<br />
The stylet is used to<br />
introduce the catheter.<br />
REF 8F EVD 30.015.02<br />
Outside Diameter 2.7 mm<br />
Inside Diameter 1.5 mm<br />
REF 10F EVD 30.035.02<br />
Outside Diameter 3.3 mm<br />
Inside Diameter 1.9 mm<br />
Material Polyurethane<br />
Length 270 mm<br />
Perforation zone 60 mm<br />
Shelf Life 3 years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
9
10<br />
External Ventricular <strong>Drainage</strong> Kit<br />
The External Ventricular <strong>Drainage</strong> Kit<br />
drains and collects cerebrospinal fluid<br />
for external ventricular drainage.<br />
The kit is comprised of a tube<br />
connector with a Luer-Lock for<br />
connection to the Ventricular<br />
Catheter, a drip chamber, and a<br />
replaceable drainage bag. The tube<br />
connector contains an access port. A<br />
three-way stopcock to connect a proximal<br />
pressure transducer, a threeway<br />
stopcock to connect a distal<br />
pressure transducer, a pump chamber<br />
and a check valve are provided.<br />
The drip chamber is aerated with a<br />
replaceable filter.<br />
All tube connectors except the ones<br />
for the filter and drainage bag are<br />
permanently glued in place. The<br />
diameters of all connecting components<br />
and stopcocks are the same<br />
as that of the ventricular catheter,<br />
thereby avoiding narrowing that can<br />
cause clogging.<br />
A special version for use with the<br />
<strong>Spiegelberg</strong> Compliance-Monitor is<br />
available. In it the tube from the distal<br />
three-way stopcock to the drip<br />
chamber is made of compressible<br />
silicone.<br />
The Luer-Lock connector<br />
connects the kit to a<br />
ventricular catheter or to<br />
an intraventricular<br />
<strong>Spiegelberg</strong> ICP-probe.<br />
The proximal three-way<br />
stopcock is used to<br />
connect to a pressure<br />
transducer.<br />
REF<br />
External Ventricular<br />
<strong>Drainage</strong> Kit EVD 30.001.01/FV800<br />
External Ventricular<br />
<strong>Drainage</strong> Kit<br />
for Compliance EVD 30.002.01/FV801<br />
Bag EVD 30.101.02<br />
Filter EVD 30.102.01/FV803<br />
Length 1900 mm<br />
Volume Drip<br />
Chamber 100 ml<br />
Volume<br />
<strong>Drainage</strong> Bag 700 ml<br />
Shelf Life 3 years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
A check valve prevents<br />
reflux.<br />
A pump chamber is used<br />
to transport <strong>CSF</strong><br />
The distal three-way<br />
stopcock is used to<br />
connect to a pressure<br />
transducer.<br />
The on-off ratchet clamp<br />
is closed during patient<br />
transport.<br />
The drip chamber is<br />
aerated with a<br />
replaceable filter<br />
The drip chamber is<br />
outfitted with velcro<br />
straps that are used for<br />
fixation to an IV pole or<br />
the EVD holder.<br />
Cerebrospinal fluid<br />
accumulates in the drip<br />
chamber and the<br />
quantity is determined in<br />
it.<br />
The on-off ratchet clamp<br />
is used to close off the<br />
discharge tube during<br />
collection.<br />
The large inner<br />
diameters of the<br />
discharge tube and the<br />
connector allow for<br />
rapid discharge.<br />
The replaceable bag is<br />
used to collect <strong>CSF</strong>. It is<br />
aerated with a filter.
External Ventricular <strong>Drainage</strong> Kit<br />
with Plate<br />
The External Ventricular <strong>Drainage</strong> Kit<br />
drains and collects cerebrospinal fluid<br />
for external ventricular drainage.<br />
The kit is comprised of a tube<br />
connector with a Luer-Lock for<br />
connection to the Ventricular<br />
Catheter, a drip chamber, and a<br />
replaceable drainage bag. The tube<br />
connector contains an access port. A<br />
three-way stopcock to connect a proximal<br />
pressure transducer, a threeway<br />
stopcock to connect a distal<br />
pressure transducer, a pump chamber<br />
and a check valve are provided.<br />
The drip chamber is aerated with a<br />
replaceable filter.<br />
The drip chamber is mounted on a<br />
plate that has scales in mmHg and<br />
cmH 2 O allowing exact positioning<br />
above the patient´s foramen of Monro<br />
level.<br />
The Luer-Lock connector<br />
connects the kit to a<br />
ventricular catheter or to<br />
an intraventricular<br />
<strong>Spiegelberg</strong> ICP-probe.<br />
The kit with clamp can<br />
be fixed to an IV pole by<br />
means of the integrated<br />
clamp.<br />
The on-off ratchet clamp<br />
is closed during patient<br />
transport.<br />
The proximal three-way<br />
stopcock is used to<br />
connect to a pressure<br />
transducer.<br />
All tube connectors except the ones<br />
for the filter and drainage bag are<br />
permanently glued in place. The<br />
diameters of all connecting components<br />
and stopcocks are the same<br />
as that of the ventricular catheter,<br />
thereby avoiding narrowing that can<br />
cause clogging.<br />
A check valve prevents<br />
reflux.<br />
A pump chamber is used<br />
to transport <strong>CSF</strong><br />
The distal three-way<br />
stopcock is used to<br />
connect to a pressure<br />
transducer.<br />
The drip chamber is<br />
aerated with a<br />
replaceable filter.<br />
The drip chamber is<br />
mounted on a plate that<br />
is hung to an IV pole.<br />
The plate has pressure<br />
scales in mmHg and<br />
cmH 2 O.<br />
Cerebrospinal fluid<br />
accumulates in the drip<br />
chamber and the<br />
quantity is determined in<br />
it.<br />
The on-off ratchet clamp<br />
is used to close off the<br />
discharge tube during<br />
collection.<br />
The large inner<br />
diameters of the<br />
discharge tube and the<br />
connector allow for<br />
rapid discharge.<br />
REF<br />
EVD Kit with plate EVD 30.003.01<br />
EVD Kit with plate<br />
with clamp EVD 30.004.01<br />
Length 1900 mm<br />
Volume<br />
Drip Chamber 100 ml<br />
Volume<br />
<strong>Drainage</strong> Bag 700 ml<br />
Shelf Life 3 years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
11
12<br />
Ventricular <strong>Drainage</strong> Bag<br />
The External Ventricular <strong>Drainage</strong> Bag<br />
drains and collects cerebrospinal fluid<br />
for external ventricular drainage,<br />
external subdural drainage and<br />
external lumbar drainage. It is<br />
indicated whenever accurate<br />
measuring of drained fluid and exact<br />
levelling are not essential.<br />
The bag has a tube with a Luer-Lock<br />
connector for connection to the<br />
catheter. An access port and a check<br />
valve are provided. The bag is aerated<br />
with a replaceable filter.<br />
The Luer-Lock connector<br />
connects the bag to a<br />
catheter.<br />
REF<br />
External Ventricular<br />
<strong>Drainage</strong> Bag EVD 30.106.01<br />
Filter EVD 30.102.01<br />
Volume 700 ml<br />
Shelf Life 3 years<br />
Duration of use short term<br />
up to 30 days<br />
EO sterile<br />
Latex free<br />
The bag is fixed to the<br />
patient’s bed or to an IV<br />
pole with a string.<br />
The bag is aerated with<br />
a replaceable filter.
EVD-Holders<br />
Holder for securing the EVD-Kit to<br />
an infusion stand<br />
The holder is used to fix the kit securely.<br />
It is outfitted with a screw clamp for<br />
attachment to infusion stands, bed<br />
frames etc. The holder is fixed in such a<br />
way that the zero mark is located at the<br />
same height as the patient’s foramen of<br />
Monro. A swivel joint adjusts the holder<br />
to a vertical position.<br />
The Velcro straps are used to fix the<br />
drip chamber securely at the desired<br />
height. The height is shown on the<br />
scale in mmHg or cmH 2 O. A fixture is<br />
available to attach an external pressure<br />
transducer at the height of the zero<br />
mark. Fixtures are available for pressure<br />
transducers from various suppliers.<br />
Fixtures for pressure transducers are<br />
also available with an integrated<br />
levelling device.<br />
REF<br />
EVD-Holder with<br />
Swivel Joint EVD 30.221.01<br />
Holder for<br />
PfM EVD-Kit EVD 30.212.01<br />
Holder for Pressure Transducer<br />
PvB EVD 30.231.01<br />
Medex LogiCal EVD 30.232.01<br />
Abbott EVD 30.233.01<br />
Baxter EVD 30.234.01<br />
Holder for Pressure Transducer<br />
with Levelling Rod<br />
PvB EVD 30.231.02<br />
Medex LogiCal EVD 30.232.02<br />
Abbott EVD 30.233.02<br />
Baxter EVD 30.234.02<br />
Material Stainless steel<br />
Rod Diameter 25 mm<br />
Rod Length 600 mm<br />
The holders for pressure<br />
transducers are available<br />
with a levelling device<br />
which has a spirit level<br />
for horizontal alignment.<br />
The drip chamber of the<br />
set is attached to the<br />
vertical post of the<br />
holder. The post is<br />
outfitted with two<br />
scales, one showing<br />
mmHg and the other<br />
showing cm H 2 O.<br />
The holder is outfitted<br />
with a screw clamp for<br />
attachment to infusion<br />
stands.<br />
A hook holds the<br />
drainage bag securely in<br />
place.<br />
The clamp has a swivel<br />
joint for vertical<br />
alignment.<br />
Holders for pressure<br />
transducers are available<br />
for different<br />
manufacturers’<br />
transducers.<br />
13
14<br />
EVD-Holder ‘Freiburg’<br />
In the holder ‘Freiburg’ the rod is<br />
fixed to a plate, which is placed unter<br />
the mattress of the bed. The weight<br />
of the matress and the weight of the<br />
patient fix the holder securely in<br />
place.<br />
The holder is adjusted such that the<br />
zero mark is at the elevation of the<br />
Foramen of Montro of the patient.<br />
When the elevation of the head-part<br />
of the bed is changed, the elevation<br />
of the drip chamber in relation to the<br />
foramen of Monro remains unchanged.<br />
A swivel joint adjusts the holder to a<br />
vertical position.<br />
The Velcro straps are used to fix the<br />
drip chamber securely at the desired<br />
height. The height is shown on the<br />
scale in mmHg or cmH 2 O. A fixture is<br />
available to attach an external<br />
pressure transducer at the height of<br />
the zero mark. Fixtures are available<br />
for pressure transducers from various<br />
suppliers.<br />
Fixtures for pressure transducers are<br />
also available with an integrated<br />
levelling device.<br />
REF<br />
EVD-Holder<br />
Freiburg<br />
left EVD 30.211.01<br />
EVD-Holder<br />
Freiburg<br />
right EVD 30.211.02<br />
EVD-Holder<br />
Freiburg<br />
left and right EVD 30.211.03<br />
Holder for<br />
PfM EVD-Kit EVD 30.212.01<br />
Holder for Pressure Transducer<br />
PvB EVD 30.231.01<br />
Medex LogiCal EVD 30.232.01<br />
Abbott EVD 30.233.01<br />
Baxter EVD 30.234.01<br />
Holder for Pressure Transducer<br />
with Levelling Rod<br />
PvB EVD 30.231.02<br />
Medex LogiCal EVD 30.232.02<br />
Abbott EVD 30.233.02<br />
Baxter EVD 30.234.02<br />
Material Stainless steel,<br />
Aluminum<br />
Rod Diameter 25 mm<br />
Rod Length 600 mm<br />
Plate Size 400 mm x 400 mm
Scientific Information about Silverline ® Technology<br />
Can we eliminate <strong>CSF</strong>-drainage infection?<br />
Infections are a serious complication of <strong>CSF</strong>drainage<br />
systems. Even with best surgical<br />
technique and utmost aseptic handling measures<br />
infections cannot be avoided completely (1, 2,<br />
4).<br />
Impregnating ventricular catheters with a<br />
combination of Rifampicin and Minocyclin, or<br />
Rifampicin and Clindamycin reduces the<br />
likelihood of catheters to become colonized and<br />
reduces the frequency of positive <strong>CSF</strong> cultures<br />
(6). However, prophylactic use of antibiotics<br />
carries the risk of infection with antibiotic<br />
resistant organisms including opportunistic<br />
infection due to organisms such as candida (8).<br />
Silver as an antimicrobial substance has been<br />
known for centuries (3). It has been used in<br />
central venous catheters for some time (Erlangen<br />
Silver Catheter).<br />
Method<br />
Particles of silver and particles of an an insoluble<br />
silver salt are incorporated in the polyurethane<br />
or silicone material of Silverline Catheters.<br />
Silver ions have a strong antiseptic effect with a<br />
broad spectrum (3, 5). Should a resistancy to<br />
silver develop under the influence of the the<br />
silver ions, the antibiotic therapy will still be<br />
possible.<br />
The particles have a large specific surface<br />
resulting in the release of silver ions in antiseptic<br />
concentration on the surface of the catheter.<br />
There are two phases to the release of the<br />
antiseptic agent: In phase one the silver salt<br />
releases silver ions in antiseptic concentration.<br />
Phase one starts immediately after placement of<br />
the catheter and lasts for several hours. In phase<br />
two silver ions are released from the metallic<br />
silver. Phase two begins some hours aftert<br />
catheter placement and it lasts for a very long<br />
time.<br />
Silver inactivates the enzyme systems with SHgroups<br />
of the cell wall that are active in the<br />
transmembraneous energy metabolism. Silver<br />
ions block the breathing chain of the bacteria<br />
(5).<br />
Results<br />
Using the roll-culture method Silverline<br />
catheters were subjected to different suspensions<br />
of bacteria for various fixed time intervals. After<br />
that, roll-cultures were done. For control<br />
purposes non-antimicrobial catheters were<br />
subjected to the same test (7).<br />
Silverline catheters demonstrated antimicrobial<br />
effects on:<br />
- Staph. aureus,<br />
- Staph. epidermidis,<br />
- Methicillin resistant Staphylococcus,<br />
- E. coli,<br />
- Pseudomonas aeruginosa,<br />
- Clostridium difficile,<br />
- Acinetobacter baumannii,<br />
- Streptococcus intermedius,<br />
- Candida albicans, and<br />
- Candida glabrata.<br />
The figure shows cultures of the Silverline<br />
catheter and of a non-antimicrobial control made<br />
of the same material after subjecting them to a<br />
suspension of Staph. aureus. The top row shows<br />
cultures of the Silverline catheter after 16 hours<br />
and 32 hours. The lower row is the control.<br />
Continuing growth can be seen clearly on the<br />
cultures of the control catheters. The cultures of<br />
Silverline catheters show markedly reduced<br />
growth after 16 hours and sterility after 32<br />
hours.<br />
In clinical studies a marked reduction of the<br />
infection rate was found (9, 10, 11).<br />
0 h 16 h 32 h<br />
Cultures of catheters after subjecting them to a suspension of Staph. aureus<br />
Upper row: Silverline catheter<br />
Lower row: Control catheter<br />
Discussion<br />
The antimicrobial effect of Silverline Catheters<br />
could be shown clearly in the in-vitro trial. The<br />
broad spectrum of efficacy and the two phases of<br />
release of the antiseptic agent make the product<br />
efficient and long lasting.<br />
Because of its broad band effect with no danger<br />
of resistancies the Silverline catheters are a new<br />
approach for preventing EVD and shunt<br />
infection.<br />
Bibliography<br />
1. Anneke, A.: Infektiöse Komplikationen von<br />
Liquoraußendrainagen. Dissertation Universität<br />
Heidelberg, 1999<br />
2. Lozier AP, Sciacca RR, Romagnoli MF,<br />
Connolly ES Ventriculostomy-related<br />
infections: A critical review of literature.<br />
Neurosurgery 51, 2002, 170-182<br />
3. Naegeli, C. v.:Über die oligodynamischen<br />
Erscheinungen an lebenden Zellen. Neue<br />
Denkschr. Allg. Schweiz. Ges. Naturwiss.<br />
33, 1893, 174 - 182<br />
4. Pfisterer, W.;Mühlbauer, M.; Czech, T.;<br />
Reinprecht, A.: Early diagnosis of external<br />
ventricular drainage infection: results of a<br />
prospective study. J Neurol Neurosurg<br />
Psychiatry 74, 2003, 929–932<br />
5. Thurmann, R.B.; Gerba, C.H.P.: The<br />
molecular mechanisms of copper and silver<br />
ion disinfection of bacteria and viruses. Crit.<br />
Rev. Environmental Control, 18, 1989, 295-<br />
315<br />
6. Zabramski J.M.; Darouiche, R.O. et al.:<br />
Efficacy of antimicrobial-impregnated<br />
external ventricular catheters: a prospective,<br />
randomized, controlled trial. J Neurosurg,<br />
98, 2003, 725-730<br />
7. Zschaler, R.: Testing of the Antimicrobial<br />
Effect of Catheter Tubing with a Roll<br />
Culture Method. www.spiegelberg.de/home/<br />
documents/Zschaler.pdf<br />
8. Kojic, E.M.; Darouiche, R.O.: Candida<br />
infections of medical devices. Clin.<br />
Microbiol. Rev., 17, 2004, 255-267<br />
9. Keong, N.C.;D. Bulters, H. Richards, M.<br />
Farrington, O. Sparrow, J.D. Pickard, P.J.<br />
Hutchinson, P.J. Kirkpatrick: The SILVER<br />
(Silver-Impregnated Line Vs EVD<br />
Randomized) Trial : A Double-blind,<br />
Prospective, Randomized Controlled Trial of<br />
an Intervention to Reduce the Rate of<br />
External Ventricular Drain Infection.<br />
Neurosurgery, 71(2):394-404, August 2012<br />
10. Izci, Y.; Secer, H.; Akay, C.; Gonul, E.: Initial<br />
experience with silver-impregnated<br />
polyurethane ventricular catheter for<br />
shunting of cerebrospinal fluid in patients<br />
with infected hydrocephalus. Neurol. Res.<br />
2008, online version.<br />
11. Fichtner, J.; Güresir, E.; Seifert, V.; Raabe,<br />
A.: Efficacy of silver-bearing external<br />
ventricular drainage catheters: a retrospective<br />
analysis. J Neurosurg, September<br />
18, 2009, DOI: 10.3171/2009.8.JNS091297<br />
15
16<br />
Catheter Reference Chart<br />
EVD<br />
Style<br />
Standard Polyurethane<br />
Diameter 1.6 mm 6F, 2.0 mm 2.5 mm 8 F, 2.7 mm 10 F, 3.3 mm<br />
270 mm long EVD 30.010.01 EVD 30.030.01<br />
w. hollow stylette, 200 mm long EVD 30.012.01 EVD 30.032.01<br />
short, 100 mm long EVD 30.011.01<br />
w. bolt fixation EVD 30.014.01 EVD 30.034.01<br />
Silverline Polyurethane<br />
ELD External Lumbar <strong>Drainage</strong> ELD 33.010.02<br />
EVD<br />
270 mm long EVD 30.020.02 EVD 30.010.02 EVD 30.030.02<br />
w. hollow stylette, 200 mm long EVD 30.012.02 EVD 30.032.02<br />
short, 100 mm long EVD 30.011.02<br />
w. bolt fixation EVD 30.014.02 EVD 30.034.02<br />
ESD External Subdural <strong>Drainage</strong> EVD 30.015.02 EVD 30.035.02<br />
Silverline Silicone<br />
EVD 270 mm long EVD 30.050.02<br />
Shunt Ventricular Shunt Catheter IVD 30.070.02<br />
Peritoneal Shunt Catheter IVD 30.080.02<br />
Manufacturer<br />
<strong>Spiegelberg</strong> (GmbH & Co.) KG<br />
Tempowerkring 4<br />
21079 Hamburg<br />
Germany<br />
Phone: +49-40-790-178-0<br />
Fax: +49-40-790-178-10<br />
email: info@spiegelberg.de<br />
http://www.spiegelberg.de<br />
DIN EN ISO 13 485 certified<br />
0297<br />
© by <strong>Spiegelberg</strong> (GmbH & Co.) KG, 2009<br />
EVDEng_Deu_Span_Port_2009V31.p65<br />
2012-08-03