<strong>Spiegelberg</strong>: <strong>CSF</strong>-<strong>Drainage</strong> Products<br />

Technology<br />

for<br />

Brains<br />

1


2<br />

Contents<br />

Antimicrobial Shunt Catheters<br />

External Ventricular <strong>Drainage</strong> Catheters<br />

Accessories<br />

Antimicrobial External Ventricular<br />

<strong>Drainage</strong> Catheters<br />

Antimicrobial Lumbar <strong>Drainage</strong><br />

Catheter<br />

Antimicrobial Subdural <strong>Drainage</strong><br />

Catheters<br />

External Ventricular <strong>Drainage</strong> Kit<br />

External Ventricular <strong>Drainage</strong> Kit with<br />

Plate<br />

External Ventricular <strong>Drainage</strong> Bag<br />

EVD-Holders<br />

Scientific Information about Silverline ®<br />

Technology<br />

Catheter Reference Chart<br />

3<br />

4<br />

5<br />

6<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

15<br />

16


Antimicrobial Ventricular Shunt Catheter<br />

Antimicrobial Peritoneal Shunt Catheter Indication<br />

Silverline Shunt Catheters are<br />

indicated to be used in all patients<br />

with an indication for internal <strong>CSF</strong>drainage.<br />

The trocar is used for<br />

tunneling the catheter.<br />

The catheter has<br />

numbered depth marks.<br />

The peritoneal catheter<br />

is made of two layers.<br />

The antiseptic<br />

radiopaque inner layer<br />

prevents colonization<br />

under the influence of<br />

<strong>CSF</strong> in an optimal way.<br />

The outer layer is made<br />

of pure silicone. The<br />

antiseptic effect is<br />

achieved by diffusion of<br />

silver ions from the inner<br />

layer. The pure silicone<br />

prevents micro fractures<br />

and calcification.<br />

Product Description<br />

Silverline Ventricular Shunt Catheters<br />

are made of antiseptic radiopaque<br />

implant grade silicone. They have<br />

numbered centimeter marks. A stylet<br />

and a trocar are delivered with the<br />

catheter.<br />

Silverline Peritoneal Shunt Catheters<br />

are made of two layers. The inner<br />

layer is made of antiseptic radiopaque<br />

implant grade silicone. The<br />

outer layer is made of pure silicone.<br />

By this construction prevention of<br />

micro- fractures and calcification is<br />

achieved.<br />

Silverline Shunt Catheters are<br />

compatible with all manufacturers´<br />

shunt valves.<br />

Technical Information<br />

The stylet is used to<br />

introduce the catheter<br />

into the ventricle.<br />

Silverline Antimicrobial Ventricular Shunt Catheter<br />

REF IVD 30.070.02<br />

Length 230 mm<br />

Silverline Antimicrobial Peritoneal Shunt Catheter<br />

REF IVD 30.080.02<br />

Length 1200 mm<br />

Set Consisting of Ventricular and Peritoneal Catheter<br />

REF IVD 30.401.02<br />

Outer Diameter 2.5 mm<br />

Inner Diameter 1.3 mm<br />

Material Silicone<br />

Shelf Life 3 Years<br />

Duration of use Long term implantable<br />

Compatible with All shunt valves designed for<br />

silicone catheters 1.3 mm ID<br />

Shelf Life 3 years<br />

Duration of use Long term<br />

implantable<br />

EO sterile<br />

Latex free<br />

3


4<br />

External Ventricular <strong>Drainage</strong> Catheters<br />

Indication<br />

External Ventricular <strong>Drainage</strong><br />

Catheters are indicated for<br />

perioperative <strong>CSF</strong>-drainage, for<br />

treatment of Subarachnoid<br />

Hemorrhage (SAH), treatment of<br />

elevated Intracranial Pressure (ICP),<br />

and whenever <strong>CSF</strong>-drainage is<br />

indicated for up to 30 days.<br />

Ventricular Catheter<br />

REF 8F EVD 30.010.01/FV804<br />

Outer Diameter 2.7 mm<br />

Inner Diameter 1.5 mm<br />

REF 10F EVD 30.030.01<br />

Outer Diameter 3.3 mm<br />

Inner Diameter 1.9 mm<br />

Material Polyurethane<br />

Length 270 mm<br />

Shelf Life 3 years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

Ventricular Catheter with Hollow<br />

Stylet 8F ‘Heese’<br />

The hollow stylet is equipped with holes<br />

that correspond to the holes in the<br />

catheter. Flow of <strong>CSF</strong> out of the stylet<br />

indicates a correct position in the<br />

ventricle. A turn of 90 degrees of the<br />

stylet shuts off the flow of <strong>CSF</strong>.<br />

REF EVD 30.012.01<br />

Material Polyurethane<br />

Outer Diameter 2.7 mm<br />

Inner Diameter 1.5 mm<br />

Length 200 mm<br />

Shelf Life 3 years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

Short Ventricular Catheter 8F<br />

The Short Ventricular Catheter is used<br />

whenever tunneling is not desired. This<br />

will reduce the time for the procedure<br />

significantly.<br />

REF EVD 30.011.01<br />

Material Polyurethane<br />

Outer Diameter 2.7 mm<br />

Inner Diameter 1.5 mm<br />

Length 100 mm<br />

Shelf Life 3 years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

Product Description<br />

The catheters are made of radiopaque<br />

polyurethane. Their round tip<br />

is closed. They have numbered<br />

centimeter marks. Stylet, trocar,<br />

Luer-Lock connector, and suturing<br />

wing are delivered with the catheter.<br />

The catheter is outfitted<br />

with lettered marks.<br />

The trocar is used for<br />

tunneling.<br />

The Luer-Lock<br />

connector for the<br />

connection with the<br />

EVD-Kit is attached to<br />

the catheter.<br />

The slitted suturing wing<br />

is used for fixation to the<br />

skin.<br />

<strong>CSF</strong> is released through<br />

the hollow stylet when<br />

the ventricle is<br />

punctured.<br />

The Luer-Lock connector<br />

is connected to the<br />

external ventricular<br />

drainage kit.<br />

The stylet is used for<br />

stiffening during<br />

insertion.


External Ventricular <strong>Drainage</strong><br />

Catheter with Cranial Bolt<br />

The ventricular catheter is fixed in<br />

the bone by means of a bolt. After<br />

making a burr hole and opening the<br />

dura the probe is placed in the<br />

ventricle with the bolt in place in the<br />

upper region of the catheter.<br />

The catheter has two<br />

sets of numbered depth<br />

marks. The first set is<br />

related to the tip of the<br />

catheter.<br />

The drill bit has an<br />

adjustable stop.<br />

The Allen wrench ist<br />

used to adjust the stop.<br />

The dura opener is used<br />

to perforate the dura<br />

mater.<br />

Accessories<br />

With the clamping nut<br />

the probe is fixed in the<br />

bolt.<br />

Then the bolt is slid down to the<br />

burr hole and screwed into the<br />

bone. Finally the probe is fixed in the<br />

bolt with the clamping nut. The<br />

Luer-Lock connector is placed in the<br />

drainage tube and connected to a<br />

drainage kit.<br />

The second set of depth<br />

marks is related to the<br />

upper edge of the bolt.<br />

Manometer Tube<br />

The manometer tube is used to<br />

determine the opening pressure. It is<br />

connected to the hollow stylet of a<br />

Heese-Catheter. Opening pressure can<br />

then be observed from the liquid level. The manometer tube is<br />

outfitted with lettered<br />

marks.<br />

The stylet is used to<br />

introduce the catheter<br />

into the ventricle.<br />

The Luer-Lock connector<br />

adapts the catheter to<br />

the EVD-Kit.<br />

REF 8F EVD 30.014.01<br />

Outer Diameter 2.7 mm<br />

Inner Diameter 1.5 mm<br />

REF 10F EVD 30.034.01<br />

Outer Diameter 3.3 mm<br />

Inner Diameter 1.9 mm<br />

Material Polyurethane<br />

Length 270 mm<br />

Shelf Life 3 Years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

REF EVD 30.013.01<br />

Material Polyurethane<br />

Outer Diameter 2.7 mm<br />

Inner Diameter 1.6 mm<br />

Length 420 mm<br />

Shelf Life 3 years<br />

Duration of use transient, up to<br />

60 minutes<br />

EO sterile<br />

Latex free<br />

5


6<br />

Antimicrobial External Ventricular <strong>Drainage</strong> Catheters<br />

Indication<br />

Silverline External Ventricular <strong>Drainage</strong><br />

Catheters are indicated for<br />

perioperative <strong>CSF</strong>-drainage, for<br />

treatment of Subarachnoid<br />

Hemorrhage (SAH), treatment of<br />

elevated Intracranial Pressure (ICP),<br />

and whenever <strong>CSF</strong>-drainage is<br />

indicated for up to 30 days.<br />

Silverline<br />

Antimicrobial Ventricular Catheter<br />

REF Polyurethane 6F EVD 30.020.02<br />

Outside Diameter 2 mm<br />

Inside Diameter 1 mm<br />

REF Polyurethane 8F EVD 30.010.02<br />

REF Silicone 8F EVD 30.050.02<br />

Outside Diameter 2.7 mm<br />

Inside Diameter 1.5 mm<br />

REF Polyurethane 10F EVD 30.030.02<br />

Outside Diameter 3.3 mm<br />

Inside Diameter 1.9 mm<br />

Length 270 mm<br />

Shelf Life 3 years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

Silverline<br />

Antimicrobial<br />

Ventricular Catheter with<br />

Hollow Stylet ‘Heese’<br />

REF 8F EVD 30.012.02<br />

Outside Diameter 2.7 mm<br />

Inside Diameter 1.5 mm<br />

REF 10F EVD 30.032.02<br />

Outside Diameter 3.3 mm<br />

Inside Diameter 1.9 mm<br />

Material Polyurethane<br />

Length 200 mm<br />

Shelf Life 3 years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

Product Description<br />

The catheters have a closed round<br />

tip. They have numbered centimeter<br />

marks. Stylet, trocar, Luer-Lock<br />

connector, and suturing wing are<br />

delivered with the catheter.<br />

The catheters are available either<br />

made of radiopaque antiseptic<br />

polyurethane, or of radiopaque<br />

antiseptic silicone.<br />

The catheter has<br />

numbered depth marks.<br />

The trocar is used for<br />

tunneling the catheter.<br />

The slitted suturing wing<br />

is used for the fixation to<br />

the skin.<br />

The Luer-Lock connector<br />

adapts the catheter to<br />

the EVD-Kit.<br />

The stylet is used to<br />

introduce the catheter<br />

into the ventricle.<br />

<strong>CSF</strong> is released through<br />

the hollow stylet when<br />

the ventricle is<br />

punctured.


Silverline<br />

Antimicrobial<br />

Short Ventricular Catheter 8F<br />

Silverline Antimicrobial<br />

Ventricular Catheter with<br />

Cranial Bolt<br />

The ventricular catheter is fixed in<br />

the bone by means of a bolt. After<br />

making a burr hole and opening the<br />

dura the catheter is placed in the<br />

ventricle with the bolt in place in the<br />

The catheter has two<br />

sets of numbered depth<br />

marks. The first set is<br />

related to the tip of the<br />

catheter.<br />

The drill bit has an<br />

adjustable stop.<br />

The Allen wrench is used<br />

to adjust the stop.<br />

The dura opener is used<br />

to perforate the dura<br />

mater.<br />

With the clamping nut<br />

the probe is fixed in the<br />

bolt.<br />

The Luer-Lock<br />

connector for the<br />

connection with the<br />

EVD-Kit is attached to<br />

the catheter.<br />

upper region of the probe.<br />

Then the bolt is slid down to the<br />

burr hole and screwed into the<br />

bone. Finally the catheter is fixed in<br />

the bolt with the clamping nut. The<br />

Luer-Lock connector is placed in the<br />

drainage tube and connected to a<br />

drainage kit.<br />

The second set of depth<br />

marks is related to the<br />

upper edge of the bolt.<br />

REF EVD 30.011.02<br />

Material Polyurethane<br />

Outside Diameter 2.7 mm<br />

Inside Diameter 1.5 mm<br />

Length 100 mm<br />

Shelf Life 3 years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

REF 8F EVD 30.014.02<br />

Outer Diameter 2.7 mm<br />

Inner Diameter 1.5 mm<br />

REF 10F EVD 30.034.02<br />

Outer Diameter 3.3 mm<br />

Inner Diameter 1.9 mm<br />

Material Polyurethane<br />

Length 270 mm<br />

Shelf Life 3 Years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

The Luer-Lock connector<br />

adapts the catheter to<br />

the EVD-Kit.<br />

The stylet is used to<br />

introduce the catheter<br />

into the ventricle.<br />

7


8<br />

Antimicrobial Lumbar <strong>Drainage</strong> Catheter<br />

Indication<br />

Silverline Lumbar <strong>Drainage</strong> Catheters<br />

are indicated for perioperative <strong>CSF</strong>drainage,<br />

for diagnosis of Normal<br />

Pressure Hydrocephalus (NPH), and<br />

whenever lumbar <strong>CSF</strong>-drainage is<br />

indicated for up to 30 days.<br />

Product Description<br />

The catheters are made of radiopaque<br />

antiseptic polyurethane. Their<br />

round tip is closed. They have<br />

numbered centimeter marks. Tuohy<br />

Needle, Luer-Lock connector, and<br />

suturing wing are delivered with the<br />

catheter.<br />

The catheter has labelled<br />

depth marks.<br />

The catheter is<br />

introduced by means of<br />

the Tuohy Needle.<br />

The butterfly suturing<br />

wing is used to fix the<br />

catheter to the skin.<br />

Scientific Information<br />

A prospective study of the University<br />

of Frankfurt shows a lower rate of<br />

vasospasm with lumbar drainage<br />

applied in patients with<br />

Subarachnoid Hemorrhage (SAH).<br />

Reference<br />

Tizi, K.; E. Güresir ; J. Beck; A. Raabe;<br />

V. Seifert ; H. Vatter: The effect of<br />

lumbar drainage on cerebral<br />

vasospasm and infarction after<br />

subarachnoid haemorrhage. DGNC<br />

Annual Meeting 2009 Abstracts,<br />

German Medical Science GMS<br />

Publishing House; 2009., http://<br />

www.egms.de/en/meetings/<br />

dgnc2009/09dgnc141.shtml<br />

The connector is used<br />

for connection with the<br />

drainage kit. It is secured<br />

with a clamping nut.<br />

Silverline<br />

Antimicrobial<br />

Lumbar <strong>Drainage</strong><br />

Catheter<br />

REF ELD 33.010.02<br />

Material Polyurethane<br />

Outer Diameter 1.6 mm<br />

Inner Diameter 0.8 mm<br />

Length 800 mm<br />

Shelf Life 3 years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free


Antimicrobial Subdural <strong>Drainage</strong> Catheters<br />

Indication<br />

Silverline Subdural <strong>Drainage</strong><br />

Catheters are indicated for drainage<br />

after evacuation of Chronic Subdural<br />

Hematoma (CSH).<br />

Product Description<br />

The catheters are made of radiopaque<br />

antiseptic polyurethane. They<br />

are available in two different<br />

diameters. The catheters have a 6 cm<br />

perforation zone close to the tip. Stylet,<br />

trocar, Luer-Lock connector, and<br />

suturing wing are delivered with the<br />

catheter.<br />

The trocar is used for<br />

tunneling the catheter.<br />

Scientific Information<br />

A prospective randomized study<br />

shows a lower recurrence rate, lower<br />

mortality, and better outcome with<br />

drainage applied for 48 hours after<br />

surgical evacuation of the CSD.<br />

The catheter has<br />

numbered depth marks.<br />

The slitted suturing wing<br />

is used for the fixation to<br />

the skin.<br />

Reference<br />

Santarius, T.; Kirkpatrick, P.;<br />

Ganesan, D.; Chia, H.; Jalloh, I.;<br />

Marcus, H.; Smielewski, P.; Price, S.;<br />

Kirollos, R.; Hutchinson, P.:<br />

Randomised controlled trial of the<br />

use of drains versus no drains after<br />

burr hole evacuation of chronic<br />

subdural haematoma. Neurosurgery:<br />

August 2009 - Volume 65 - Issue 2 -<br />

p 401, doi: 10.1227<br />

01.neu.0000358671.05488.a2<br />

Silverline<br />

Antimicrobial Subdural<br />

<strong>Drainage</strong> Catheter<br />

The Luer-Lock connector<br />

adapts the catheter to<br />

the EVD-Kit.<br />

The stylet is used to<br />

introduce the catheter.<br />

REF 8F EVD 30.015.02<br />

Outside Diameter 2.7 mm<br />

Inside Diameter 1.5 mm<br />

REF 10F EVD 30.035.02<br />

Outside Diameter 3.3 mm<br />

Inside Diameter 1.9 mm<br />

Material Polyurethane<br />

Length 270 mm<br />

Perforation zone 60 mm<br />

Shelf Life 3 years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

9


10<br />

External Ventricular <strong>Drainage</strong> Kit<br />

The External Ventricular <strong>Drainage</strong> Kit<br />

drains and collects cerebrospinal fluid<br />

for external ventricular drainage.<br />

The kit is comprised of a tube<br />

connector with a Luer-Lock for<br />

connection to the Ventricular<br />

Catheter, a drip chamber, and a<br />

replaceable drainage bag. The tube<br />

connector contains an access port. A<br />

three-way stopcock to connect a proximal<br />

pressure transducer, a threeway<br />

stopcock to connect a distal<br />

pressure transducer, a pump chamber<br />

and a check valve are provided.<br />

The drip chamber is aerated with a<br />

replaceable filter.<br />

All tube connectors except the ones<br />

for the filter and drainage bag are<br />

permanently glued in place. The<br />

diameters of all connecting components<br />

and stopcocks are the same<br />

as that of the ventricular catheter,<br />

thereby avoiding narrowing that can<br />

cause clogging.<br />

A special version for use with the<br />

<strong>Spiegelberg</strong> Compliance-Monitor is<br />

available. In it the tube from the distal<br />

three-way stopcock to the drip<br />

chamber is made of compressible<br />

silicone.<br />

The Luer-Lock connector<br />

connects the kit to a<br />

ventricular catheter or to<br />

an intraventricular<br />

<strong>Spiegelberg</strong> ICP-probe.<br />

The proximal three-way<br />

stopcock is used to<br />

connect to a pressure<br />

transducer.<br />

REF<br />

External Ventricular<br />

<strong>Drainage</strong> Kit EVD 30.001.01/FV800<br />

External Ventricular<br />

<strong>Drainage</strong> Kit<br />

for Compliance EVD 30.002.01/FV801<br />

Bag EVD 30.101.02<br />

Filter EVD 30.102.01/FV803<br />

Length 1900 mm<br />

Volume Drip<br />

Chamber 100 ml<br />

Volume<br />

<strong>Drainage</strong> Bag 700 ml<br />

Shelf Life 3 years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

A check valve prevents<br />

reflux.<br />

A pump chamber is used<br />

to transport <strong>CSF</strong><br />

The distal three-way<br />

stopcock is used to<br />

connect to a pressure<br />

transducer.<br />

The on-off ratchet clamp<br />

is closed during patient<br />

transport.<br />

The drip chamber is<br />

aerated with a<br />

replaceable filter<br />

The drip chamber is<br />

outfitted with velcro<br />

straps that are used for<br />

fixation to an IV pole or<br />

the EVD holder.<br />

Cerebrospinal fluid<br />

accumulates in the drip<br />

chamber and the<br />

quantity is determined in<br />

it.<br />

The on-off ratchet clamp<br />

is used to close off the<br />

discharge tube during<br />

collection.<br />

The large inner<br />

diameters of the<br />

discharge tube and the<br />

connector allow for<br />

rapid discharge.<br />

The replaceable bag is<br />

used to collect <strong>CSF</strong>. It is<br />

aerated with a filter.


External Ventricular <strong>Drainage</strong> Kit<br />

with Plate<br />

The External Ventricular <strong>Drainage</strong> Kit<br />

drains and collects cerebrospinal fluid<br />

for external ventricular drainage.<br />

The kit is comprised of a tube<br />

connector with a Luer-Lock for<br />

connection to the Ventricular<br />

Catheter, a drip chamber, and a<br />

replaceable drainage bag. The tube<br />

connector contains an access port. A<br />

three-way stopcock to connect a proximal<br />

pressure transducer, a threeway<br />

stopcock to connect a distal<br />

pressure transducer, a pump chamber<br />

and a check valve are provided.<br />

The drip chamber is aerated with a<br />

replaceable filter.<br />

The drip chamber is mounted on a<br />

plate that has scales in mmHg and<br />

cmH 2 O allowing exact positioning<br />

above the patient´s foramen of Monro<br />

level.<br />

The Luer-Lock connector<br />

connects the kit to a<br />

ventricular catheter or to<br />

an intraventricular<br />

<strong>Spiegelberg</strong> ICP-probe.<br />

The kit with clamp can<br />

be fixed to an IV pole by<br />

means of the integrated<br />

clamp.<br />

The on-off ratchet clamp<br />

is closed during patient<br />

transport.<br />

The proximal three-way<br />

stopcock is used to<br />

connect to a pressure<br />

transducer.<br />

All tube connectors except the ones<br />

for the filter and drainage bag are<br />

permanently glued in place. The<br />

diameters of all connecting components<br />

and stopcocks are the same<br />

as that of the ventricular catheter,<br />

thereby avoiding narrowing that can<br />

cause clogging.<br />

A check valve prevents<br />

reflux.<br />

A pump chamber is used<br />

to transport <strong>CSF</strong><br />

The distal three-way<br />

stopcock is used to<br />

connect to a pressure<br />

transducer.<br />

The drip chamber is<br />

aerated with a<br />

replaceable filter.<br />

The drip chamber is<br />

mounted on a plate that<br />

is hung to an IV pole.<br />

The plate has pressure<br />

scales in mmHg and<br />

cmH 2 O.<br />

Cerebrospinal fluid<br />

accumulates in the drip<br />

chamber and the<br />

quantity is determined in<br />

it.<br />

The on-off ratchet clamp<br />

is used to close off the<br />

discharge tube during<br />

collection.<br />

The large inner<br />

diameters of the<br />

discharge tube and the<br />

connector allow for<br />

rapid discharge.<br />

REF<br />

EVD Kit with plate EVD 30.003.01<br />

EVD Kit with plate<br />

with clamp EVD 30.004.01<br />

Length 1900 mm<br />

Volume<br />

Drip Chamber 100 ml<br />

Volume<br />

<strong>Drainage</strong> Bag 700 ml<br />

Shelf Life 3 years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

11


12<br />

Ventricular <strong>Drainage</strong> Bag<br />

The External Ventricular <strong>Drainage</strong> Bag<br />

drains and collects cerebrospinal fluid<br />

for external ventricular drainage,<br />

external subdural drainage and<br />

external lumbar drainage. It is<br />

indicated whenever accurate<br />

measuring of drained fluid and exact<br />

levelling are not essential.<br />

The bag has a tube with a Luer-Lock<br />

connector for connection to the<br />

catheter. An access port and a check<br />

valve are provided. The bag is aerated<br />

with a replaceable filter.<br />

The Luer-Lock connector<br />

connects the bag to a<br />

catheter.<br />

REF<br />

External Ventricular<br />

<strong>Drainage</strong> Bag EVD 30.106.01<br />

Filter EVD 30.102.01<br />

Volume 700 ml<br />

Shelf Life 3 years<br />

Duration of use short term<br />

up to 30 days<br />

EO sterile<br />

Latex free<br />

The bag is fixed to the<br />

patient’s bed or to an IV<br />

pole with a string.<br />

The bag is aerated with<br />

a replaceable filter.


EVD-Holders<br />

Holder for securing the EVD-Kit to<br />

an infusion stand<br />

The holder is used to fix the kit securely.<br />

It is outfitted with a screw clamp for<br />

attachment to infusion stands, bed<br />

frames etc. The holder is fixed in such a<br />

way that the zero mark is located at the<br />

same height as the patient’s foramen of<br />

Monro. A swivel joint adjusts the holder<br />

to a vertical position.<br />

The Velcro straps are used to fix the<br />

drip chamber securely at the desired<br />

height. The height is shown on the<br />

scale in mmHg or cmH 2 O. A fixture is<br />

available to attach an external pressure<br />

transducer at the height of the zero<br />

mark. Fixtures are available for pressure<br />

transducers from various suppliers.<br />

Fixtures for pressure transducers are<br />

also available with an integrated<br />

levelling device.<br />

REF<br />

EVD-Holder with<br />

Swivel Joint EVD 30.221.01<br />

Holder for<br />

PfM EVD-Kit EVD 30.212.01<br />

Holder for Pressure Transducer<br />

PvB EVD 30.231.01<br />

Medex LogiCal EVD 30.232.01<br />

Abbott EVD 30.233.01<br />

Baxter EVD 30.234.01<br />

Holder for Pressure Transducer<br />

with Levelling Rod<br />

PvB EVD 30.231.02<br />

Medex LogiCal EVD 30.232.02<br />

Abbott EVD 30.233.02<br />

Baxter EVD 30.234.02<br />

Material Stainless steel<br />

Rod Diameter 25 mm<br />

Rod Length 600 mm<br />

The holders for pressure<br />

transducers are available<br />

with a levelling device<br />

which has a spirit level<br />

for horizontal alignment.<br />

The drip chamber of the<br />

set is attached to the<br />

vertical post of the<br />

holder. The post is<br />

outfitted with two<br />

scales, one showing<br />

mmHg and the other<br />

showing cm H 2 O.<br />

The holder is outfitted<br />

with a screw clamp for<br />

attachment to infusion<br />

stands.<br />

A hook holds the<br />

drainage bag securely in<br />

place.<br />

The clamp has a swivel<br />

joint for vertical<br />

alignment.<br />

Holders for pressure<br />

transducers are available<br />

for different<br />

manufacturers’<br />

transducers.<br />

13


14<br />

EVD-Holder ‘Freiburg’<br />

In the holder ‘Freiburg’ the rod is<br />

fixed to a plate, which is placed unter<br />

the mattress of the bed. The weight<br />

of the matress and the weight of the<br />

patient fix the holder securely in<br />

place.<br />

The holder is adjusted such that the<br />

zero mark is at the elevation of the<br />

Foramen of Montro of the patient.<br />

When the elevation of the head-part<br />

of the bed is changed, the elevation<br />

of the drip chamber in relation to the<br />

foramen of Monro remains unchanged.<br />

A swivel joint adjusts the holder to a<br />

vertical position.<br />

The Velcro straps are used to fix the<br />

drip chamber securely at the desired<br />

height. The height is shown on the<br />

scale in mmHg or cmH 2 O. A fixture is<br />

available to attach an external<br />

pressure transducer at the height of<br />

the zero mark. Fixtures are available<br />

for pressure transducers from various<br />

suppliers.<br />

Fixtures for pressure transducers are<br />

also available with an integrated<br />

levelling device.<br />

REF<br />

EVD-Holder<br />

Freiburg<br />

left EVD 30.211.01<br />

EVD-Holder<br />

Freiburg<br />

right EVD 30.211.02<br />

EVD-Holder<br />

Freiburg<br />

left and right EVD 30.211.03<br />

Holder for<br />

PfM EVD-Kit EVD 30.212.01<br />

Holder for Pressure Transducer<br />

PvB EVD 30.231.01<br />

Medex LogiCal EVD 30.232.01<br />

Abbott EVD 30.233.01<br />

Baxter EVD 30.234.01<br />

Holder for Pressure Transducer<br />

with Levelling Rod<br />

PvB EVD 30.231.02<br />

Medex LogiCal EVD 30.232.02<br />

Abbott EVD 30.233.02<br />

Baxter EVD 30.234.02<br />

Material Stainless steel,<br />

Aluminum<br />

Rod Diameter 25 mm<br />

Rod Length 600 mm<br />

Plate Size 400 mm x 400 mm


Scientific Information about Silverline ® Technology<br />

Can we eliminate <strong>CSF</strong>-drainage infection?<br />

Infections are a serious complication of <strong>CSF</strong>drainage<br />

systems. Even with best surgical<br />

technique and utmost aseptic handling measures<br />

infections cannot be avoided completely (1, 2,<br />

4).<br />

Impregnating ventricular catheters with a<br />

combination of Rifampicin and Minocyclin, or<br />

Rifampicin and Clindamycin reduces the<br />

likelihood of catheters to become colonized and<br />

reduces the frequency of positive <strong>CSF</strong> cultures<br />

(6). However, prophylactic use of antibiotics<br />

carries the risk of infection with antibiotic<br />

resistant organisms including opportunistic<br />

infection due to organisms such as candida (8).<br />

Silver as an antimicrobial substance has been<br />

known for centuries (3). It has been used in<br />

central venous catheters for some time (Erlangen<br />

Silver Catheter).<br />

Method<br />

Particles of silver and particles of an an insoluble<br />

silver salt are incorporated in the polyurethane<br />

or silicone material of Silverline Catheters.<br />

Silver ions have a strong antiseptic effect with a<br />

broad spectrum (3, 5). Should a resistancy to<br />

silver develop under the influence of the the<br />

silver ions, the antibiotic therapy will still be<br />

possible.<br />

The particles have a large specific surface<br />

resulting in the release of silver ions in antiseptic<br />

concentration on the surface of the catheter.<br />

There are two phases to the release of the<br />

antiseptic agent: In phase one the silver salt<br />

releases silver ions in antiseptic concentration.<br />

Phase one starts immediately after placement of<br />

the catheter and lasts for several hours. In phase<br />

two silver ions are released from the metallic<br />

silver. Phase two begins some hours aftert<br />

catheter placement and it lasts for a very long<br />

time.<br />

Silver inactivates the enzyme systems with SHgroups<br />

of the cell wall that are active in the<br />

transmembraneous energy metabolism. Silver<br />

ions block the breathing chain of the bacteria<br />

(5).<br />

Results<br />

Using the roll-culture method Silverline<br />

catheters were subjected to different suspensions<br />

of bacteria for various fixed time intervals. After<br />

that, roll-cultures were done. For control<br />

purposes non-antimicrobial catheters were<br />

subjected to the same test (7).<br />

Silverline catheters demonstrated antimicrobial<br />

effects on:<br />

- Staph. aureus,<br />

- Staph. epidermidis,<br />

- Methicillin resistant Staphylococcus,<br />

- E. coli,<br />

- Pseudomonas aeruginosa,<br />

- Clostridium difficile,<br />

- Acinetobacter baumannii,<br />

- Streptococcus intermedius,<br />

- Candida albicans, and<br />

- Candida glabrata.<br />

The figure shows cultures of the Silverline<br />

catheter and of a non-antimicrobial control made<br />

of the same material after subjecting them to a<br />

suspension of Staph. aureus. The top row shows<br />

cultures of the Silverline catheter after 16 hours<br />

and 32 hours. The lower row is the control.<br />

Continuing growth can be seen clearly on the<br />

cultures of the control catheters. The cultures of<br />

Silverline catheters show markedly reduced<br />

growth after 16 hours and sterility after 32<br />

hours.<br />

In clinical studies a marked reduction of the<br />

infection rate was found (9, 10, 11).<br />

0 h 16 h 32 h<br />

Cultures of catheters after subjecting them to a suspension of Staph. aureus<br />

Upper row: Silverline catheter<br />

Lower row: Control catheter<br />

Discussion<br />

The antimicrobial effect of Silverline Catheters<br />

could be shown clearly in the in-vitro trial. The<br />

broad spectrum of efficacy and the two phases of<br />

release of the antiseptic agent make the product<br />

efficient and long lasting.<br />

Because of its broad band effect with no danger<br />

of resistancies the Silverline catheters are a new<br />

approach for preventing EVD and shunt<br />

infection.<br />

Bibliography<br />

1. Anneke, A.: Infektiöse Komplikationen von<br />

Liquoraußendrainagen. Dissertation Universität<br />

Heidelberg, 1999<br />

2. Lozier AP, Sciacca RR, Romagnoli MF,<br />

Connolly ES Ventriculostomy-related<br />

infections: A critical review of literature.<br />

Neurosurgery 51, 2002, 170-182<br />

3. Naegeli, C. v.:Über die oligodynamischen<br />

Erscheinungen an lebenden Zellen. Neue<br />

Denkschr. Allg. Schweiz. Ges. Naturwiss.<br />

33, 1893, 174 - 182<br />

4. Pfisterer, W.;Mühlbauer, M.; Czech, T.;<br />

Reinprecht, A.: Early diagnosis of external<br />

ventricular drainage infection: results of a<br />

prospective study. J Neurol Neurosurg<br />

Psychiatry 74, 2003, 929–932<br />

5. Thurmann, R.B.; Gerba, C.H.P.: The<br />

molecular mechanisms of copper and silver<br />

ion disinfection of bacteria and viruses. Crit.<br />

Rev. Environmental Control, 18, 1989, 295-<br />

315<br />

6. Zabramski J.M.; Darouiche, R.O. et al.:<br />

Efficacy of antimicrobial-impregnated<br />

external ventricular catheters: a prospective,<br />

randomized, controlled trial. J Neurosurg,<br />

98, 2003, 725-730<br />

7. Zschaler, R.: Testing of the Antimicrobial<br />

Effect of Catheter Tubing with a Roll<br />

Culture Method. www.spiegelberg.de/home/<br />

documents/Zschaler.pdf<br />

8. Kojic, E.M.; Darouiche, R.O.: Candida<br />

infections of medical devices. Clin.<br />

Microbiol. Rev., 17, 2004, 255-267<br />

9. Keong, N.C.;D. Bulters, H. Richards, M.<br />

Farrington, O. Sparrow, J.D. Pickard, P.J.<br />

Hutchinson, P.J. Kirkpatrick: The SILVER<br />

(Silver-Impregnated Line Vs EVD<br />

Randomized) Trial : A Double-blind,<br />

Prospective, Randomized Controlled Trial of<br />

an Intervention to Reduce the Rate of<br />

External Ventricular Drain Infection.<br />

Neurosurgery, 71(2):394-404, August 2012<br />

10. Izci, Y.; Secer, H.; Akay, C.; Gonul, E.: Initial<br />

experience with silver-impregnated<br />

polyurethane ventricular catheter for<br />

shunting of cerebrospinal fluid in patients<br />

with infected hydrocephalus. Neurol. Res.<br />

2008, online version.<br />

11. Fichtner, J.; Güresir, E.; Seifert, V.; Raabe,<br />

A.: Efficacy of silver-bearing external<br />

ventricular drainage catheters: a retrospective<br />

analysis. J Neurosurg, September<br />

18, 2009, DOI: 10.3171/2009.8.JNS091297<br />

15


16<br />

Catheter Reference Chart<br />

EVD<br />

Style<br />

Standard Polyurethane<br />

Diameter 1.6 mm 6F, 2.0 mm 2.5 mm 8 F, 2.7 mm 10 F, 3.3 mm<br />

270 mm long EVD 30.010.01 EVD 30.030.01<br />

w. hollow stylette, 200 mm long EVD 30.012.01 EVD 30.032.01<br />

short, 100 mm long EVD 30.011.01<br />

w. bolt fixation EVD 30.014.01 EVD 30.034.01<br />

Silverline Polyurethane<br />

ELD External Lumbar <strong>Drainage</strong> ELD 33.010.02<br />

EVD<br />

270 mm long EVD 30.020.02 EVD 30.010.02 EVD 30.030.02<br />

w. hollow stylette, 200 mm long EVD 30.012.02 EVD 30.032.02<br />

short, 100 mm long EVD 30.011.02<br />

w. bolt fixation EVD 30.014.02 EVD 30.034.02<br />

ESD External Subdural <strong>Drainage</strong> EVD 30.015.02 EVD 30.035.02<br />

Silverline Silicone<br />

EVD 270 mm long EVD 30.050.02<br />

Shunt Ventricular Shunt Catheter IVD 30.070.02<br />

Peritoneal Shunt Catheter IVD 30.080.02<br />

Manufacturer<br />

<strong>Spiegelberg</strong> (GmbH & Co.) KG<br />

Tempowerkring 4<br />

21079 Hamburg<br />

Germany<br />

Phone: +49-40-790-178-0<br />

Fax: +49-40-790-178-10<br />

email: info@spiegelberg.de<br />

http://www.spiegelberg.de<br />

DIN EN ISO 13 485 certified<br />

0297<br />

© by <strong>Spiegelberg</strong> (GmbH & Co.) KG, 2009<br />