<strong>AT</strong> <strong>Command</strong> <strong>Set</strong> Reference<br />

Version 1.08<br />

2.4.2.8. <strong>AT</strong>+CR Service Reporting Control<br />

<strong>Command</strong> Function This command is used to control the display<br />

of intermediate result code (+CR )<br />

status.<br />

<strong>Command</strong> Functional Response Control<br />

Group<br />

<strong>Command</strong> Format Query <strong>AT</strong>+CR=?<br />

Response +CR: (0,1)<br />

OK<br />

Write Format <strong>AT</strong>+CR=<br />

Response OK<br />

Read Format <strong>AT</strong>+CR?<br />

Response +CR: 0<br />

OK<br />

Execution Format N/A<br />

Response N/A<br />

Parameter Values<br />

0 disable<br />

1 enable<br />

ASYNC asynchronous transparent<br />

SYNC synchronous transparent<br />

REL ASYNC asynchronous non-<br />

transparent<br />

REL SYNC synchronous non-<br />

transparent<br />

Reference GSM Ref. 07.07 Chapter 6.9<br />

Standard Scope Mandatory<br />

Enfora Implementation Scope Full<br />

GSM0107PB001MAN Page 25 of 370 1.08 – 25 January 2007