5 Connection<br />

5.1 +iBDRA — Forces iChip into Auto Baud Rate Mode<br />

Syntax: <strong>AT+i</strong>BDRA<br />

Result code:<br />

Connection<br />

Forces the iChip into auto baud rate mode. The following A, AT<br />

or <strong>AT+i</strong> command (in any combination of upper or lowercase)<br />

from the host will synchronize on the host‘s baud rate. iChip<br />

supports auto baud rate detection for the following baud rates:<br />

2400, 4800, 9600, 19200, 38400, 57600, and 115200.<br />

I/OK This result code is sent using the previous baud rate.<br />

<strong>AT+i</strong> Programmer‘s <strong>Manual</strong> Version 8.21 5-1