33.14 Remote Firmware Update Parameters<br />

Nonvolatile Parameter Database<br />

33.14.1 +iUEN — Remote Firmware Update Flag<br />

Syntax: <strong>AT+i</strong>UEN=<br />

Sets the remote firmware update flag.<br />

Parameters: v = 0 or 1<br />

Command Options:<br />

v=0 Update only to a firmware version that is newer than the<br />

currently installed one.<br />

v=1 Update to any firmware version available.<br />

Default: 0<br />

Result Code:<br />

I/OK If v = 0 or 1<br />

I/ERROR Otherwise<br />

<strong>AT+i</strong>UEN~v Temporarily set the remote firmware update flag to v for the<br />

duration of the current session. The permanent value will be<br />

restored after completing the current session.<br />

<strong>AT+i</strong>UEN? Reports the current value of the remote firmware update flag<br />

followed by I/OK.<br />

<strong>AT+i</strong>UEN=? Returns the message ―0-1‖ followed by I/OK.