Nonvolatile Parameter Database<br />

33.13.14 +iSDT — SerialNET Dialup Timeout<br />

Syntax: <strong>AT+i</strong>SDT=n Permanently sets the SerialNET Dial timeout when<br />

waking up a remote SerialNET server.<br />

Parameters: n = Number of seconds to allow after dialing up the<br />

remote SerialNET server, before hanging up.<br />

Command Options:<br />

Default: 20 [seconds]<br />

n = 0..255 [seconds].<br />

Result code:<br />

I/OK If n is within limits.<br />

I/ERROR Otherwise<br />

<strong>AT+i</strong>SDT? Report the current SerialNET dial timeout.<br />

The reply is followed by I/OK.<br />

<strong>AT+i</strong>SDT=? Returns the message "0-255".<br />

The reply is followed by I/OK.