Nonvolatile Parameter Database<br />

33.13.8 +iMCBF — Maximum Characters before Socket Flush<br />

Syntax: <strong>AT+i</strong>MCBF=n Permanently sets max number of characters before<br />

flushing the SerialNET socket.<br />

Parameters: n = maximum number of characters received on the<br />

serial link before flushing the SerialNET socket.<br />

Command Options:<br />

n = 0 .. 1460<br />

Default: 0 – No specific limit. Flushing governed by Network.<br />

Result code:<br />

I/OK If n is within limits.<br />

I/ERROR Otherwise.<br />

<strong>AT+i</strong>MCBF? Report the current maximum number of characters<br />

before flushing the SerialNET socket.<br />

The reply is followed by I/OK.<br />

<strong>AT+i</strong>MCBF=? Returns the message "0-1460".<br />