Nonvolatile Parameter Database<br />

33.13.7 +iFCHR — Flush Character<br />

Syntax: <strong>AT+i</strong>FCHR=flush_chr Permanently sets flush character in SerialNET<br />

mode.<br />

Parameters: flush_chr = character received on serial link to<br />

signal socket flush in SerialNET mode.<br />

Command Options:<br />

flush_chr = ‗‘ Empty: No Flush character defined. The<br />

SerialNET socket will not be flushed as a<br />

result of receiving a special flush<br />

character.<br />

flush_chr = ‗a‘ – ‗z‘ | ‗A‘ – ‗Z‘ | ‗0‘ – ‗9‘ | <br />

where,<br />

= \x<br />

= 00-FF<br />

Default: Empty. No flush character defined.<br />

Result code:<br />

I/OK If flush_chr is empty or a legal character<br />

representation.<br />

I/ERROR Otherwise.<br />

<strong>AT+i</strong>FCHR? Report the current flush character.<br />

The reply is followed by I/OK.<br />

<strong>AT+i</strong>FCHR=? Returns the message ‗String‘.<br />

The reply is followed by I/OK.