Nonvolatile Parameter Database<br />

33.10.3 +iIPA — Active IP Address<br />

Syntax: <strong>AT+i</strong>IPA= IP address Changes the active IP to IP address.<br />

Parameters: IP address = IP address.<br />

Command Options:<br />

IP address = IP ADDR. will be assigned as the<br />

active iChip LAN / iChip Plus IP<br />

address.<br />

Also changes the permanent Default<br />

IP address in nonvolatile memory. See<br />

description of the DIP parameter.<br />

Valid only for iChip LAN / iChip Plus.<br />

Default: Contents of the DIP parameter at power up.<br />

Result code:<br />

I/OK If IP address is empty or a legal IP address.<br />

I/ERROR Otherwise.<br />

<strong>AT+i</strong>IPA? Report the current IP address.<br />

<strong>AT+i</strong>IPA~IP address Temporarily set the current IP address. The<br />

permanent IP address (stored in the DIP parameter)<br />

will be restored/resolved after completing the next<br />

session, whether the session was successful or not.<br />

<strong>AT+i</strong>IPA=? Returns the message ‗IP addr.‘.<br />

The reply is followed by I/OK.<br />

Note: The IP address is always 0.0.0.0 when iChip is offline.