33.4.4 +iPWD — Define Connection Password<br />

Syntax: <strong>AT+i</strong>PWD=pass<br />

Sets connection password.<br />

Nonvolatile Parameter Database<br />

Parameters: pass=Password to be used when logging onto the ISP.<br />

Command Options:<br />

pass='' Empty — no password defined.<br />

pass= password is used to login to the ISP.<br />

Default: Empty — no password defined. The login password can be<br />

defined ad-hoc.<br />

Result Code:<br />

I/OK If password is an empty or a legal ISP login password.<br />

I/ERROR Otherwise<br />

<strong>AT+i</strong>PWD~pass Temporarily sets the login password to pass. The permanent<br />

value will be restored after completing the next session,<br />

whether the session was successful or not.<br />

<strong>AT+i</strong>PWD? Reports the current login password. The reported value will<br />

consist of '*' characters. The number of '*' characters shall<br />

reflect the number of characters in the actual password. If a<br />

password does not exist only will be returned. The<br />

reply is followed by I/OK.<br />

<strong>AT+i</strong>PWD=? Returns the message ‗String‘ followed by I/OK.